Bently Nevada 330171-00-33-50-01-05 is a threaded 3300 5 mm proximity probe for non-contact shaft position and vibration measurement. Its order code defines a 3.3 in case and 5.0 m integral probe cable.
- Uses an eddy-current sensing tip for conductive shaft targets
- Connects through the ClickLoc coaxial interface with its protector
- Works as one element of the matched 3300 5 mm transducer chain
- Supports static gap and dynamic machinery-motion monitoring
330171-00-33-50-01-05 operates with 3300 XL extension cable, 3300 XL 5 mm Proximitor Sensor, conductive shaft target, monitoring channel.
Typical engineered duties include Extended-case machine penetration points, Fluid-film bearing shaft monitoring, Keyphasor phase reference pickup, Rotational speed measurement.
Important Notice: Verify the complete 330171-00-33-50-01-05 order code, mounting clearance, cable route and transducer-system electrical length before installation; a different BB or CC code changes the physical configuration.
Apter Power 330171-00-33-50-01-05 Manuals and Guides
Important Notice: The first document is an Apter Power 330171-00-33-50-01-05 model-specific technical reference. The second is a distinct document for installation, configuration or system engineering.
330171-00-33-50-01-05 Extended-case machine penetration pointsUses an eddy-current sensing tip for conductive shaft targets
330171-00-33-50-01-05 Fluid-film bearing shaft monitoringConnects through the ClickLoc coaxial interface with its protector
330171-00-33-50-01-05 Keyphasor phase reference pickupWorks as one element of the matched 3300 5 mm transducer chain
330171-00-33-50-01-05 Rotational speed measurementSupports static gap and dynamic machinery-motion monitoring
Read the applicable Bently Nevada installation instructions before work. Verify 330171-00-33-50-01-05 and the installed-system configuration.
1Confirm that the probe route and mounting arrangement accept the 3.3 in case.
2Use a transducer chain engineered for the 5.0 m probe lead.
3Protect the ClickLoc mating surfaces from contamination during assembly.
4Set and verify the mechanical gap before enabling the monitoring channel.
5Commission 330171-00-33-50-01-05 under controlled conditions and retain the completed functional-test record before release.