Speak to a sourcing specialist
sales13@apterpower.com
Get a quick price for 82367-01
E-mail *
Mobile *
Company
Content *
Quantity *
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy

What happens after you enquire

  • 1

    Requirement review

    We review the part number, quantity and delivery requirements and ask for any missing details.
  • 2

    Quotation and availability

    We confirm the proposed item, condition, availability, price and estimated lead time in the quotation.
  • 3

    Order confirmation and dispatch

    Once the quotation and purchasing details are agreed, your contact will coordinate the order and available dispatch information.

Technical specifications for 82367-01

  • Manufacturer:
    Bently Nevada
  • Product Category:
    Machinery Monitoring Systems
  • Spare Part Number:
    82367-01
  • Estimated shipping dimensions:
    5x9.8x22.8cm
  • Weight:
    0.28 kg
  • Tariff Code:
    8537101190
  • Counliy of origin:
    USA
  • Monitor families:
    3300/30 and 3300/35
  • Component role:
    Thermocouple input module
  • Signal type:
    Thermocouple
  • Channel context:
    Six-channel temperature monitoring
  • Wiring control:
    Maintain thermocouple type and polarity
  • Acceptance:
    Verify channel indication and alarm response

Information

Overview Manuals Common Applications Product Precautions
Bently Nevada 82367-01 provides the thermocouple input interface used by the corresponding six-channel temperature monitor arrangement.
  • Interfaces thermocouple signals with the monitor channels.
  • Supports six-channel temperature-monitor configurations.
  • Pairs with compatible 3300/30 and 3300/35 monitor executions.
  • Requires correct thermocouple polarity, type and channel assignment.

The thermocouple input module must remain within its intended measurement or monitoring chain. Match its interfaces, wiring and channel configuration before returning protection to service.

Important Notice: Confirm the complete 82367-01 marking, mating interfaces and controlled channel configuration before installation.

Bently Nevada 82367-01 Manuals & Downloads
Bently Nevada 82367-01 Technical Reference (PDF)Bently Nevada 82367-01 Installation & Commissioning Guide (PDF)

The Technical Reference covers product function, interfaces and technical selection. The installation guide covers identification, connection checks, commissioning and the acceptance record.

Bearing temperature
Receive thermocouple signals from qualified bearing measurement points.
Process temperature
Interface supported thermocouple loops with the six-channel monitor.
Temperature protection
Provide channel inputs for configured temperature alarms.
Monitor maintenance
Replace the matching thermocouple input module while preserving channel assignments.
Before installing Bently Nevada 82367-01, confirm the mating interface, wiring arrangement and controlled channel configuration.
1
Confirm 82367-01 and the compatible monitor execution before removal.
2
Record thermocouple type, polarity and channel position for every input.
3
Isolate the monitor and field loops before disconnecting conductors.
4
Keep thermocouple extension-wire materials consistent through the circuit.
5
Do not interchange channel assignments or reverse polarity.
6
Tighten terminals evenly and maintain shield and grounding practice.
7
Compare each channel with a known input or approved simulator.
8
Verify indication, alarm and relay response before release.

Technical notes

Confirm the complete 82367-01 marking, mating interfaces and controlled channel configuration before installation.

FAQ View All FAQ

  • What signal type is accepted by Bently Nevada 82367-01?
    It is a thermocouple input module.
  • Which monitor families use Bently Nevada 82367-01?
    It is listed for compatible 3300/30 and 3300/35 temperature monitor configurations.
  • How many monitoring channels are associated with Bently Nevada 82367-01?
    It serves the six-channel temperature-monitor arrangement.
  • What wiring details must be preserved for Bently Nevada 82367-01?
    Retain thermocouple type, polarity and channel assignment.
  • Can ordinary copper wire replace thermocouple extension wire at Bently Nevada 82367-01?
    Use only the extension-wire material required by the thermocouple circuit.
  • How should Bently Nevada 82367-01 be checked after wiring?
    Apply a known input or approved simulator to each affected channel.
  • What polarity problem can affect Bently Nevada 82367-01?
    Reversed thermocouple polarity can drive the indicated temperature in the wrong direction.
  • What completes commissioning of Bently Nevada 82367-01?
    Verify indication, channel alarms and the configured relay response.
Related reading

Related cases and sourcing guidance

View all case studies
Manufacturers

Product Browsing History

Revisit the products you recently viewed on Apter Power.
SPEAK TO OUR TEAM
Let’s find the right solution for you.
Send us the part number, quantity and delivery destination. Our team will help confirm availability and lead time.
  • Whatsapp: +86 18030235313

    Send us a message.
  • sales13@apterpower.com

    Complete our online form.
  • +86 18030235313

    Speak to our team in your native language.