Match the complete marking
Compare the full Bently Nevada 330851-02-000-060-10-00-CN marking and selected configuration with the installed component before accepting a replacement.
-
Check the offered item before ordering
Request clear label and connector photographs of Bently Nevada 330851-02-000-060-10-00-CN. Ask your maintenance team to compare the offered unit with the installed equipment and the applicable Bently Nevada 3300 XL 25 mm Proximity Transducer System, 163236 Rev. M before ordering.
Technical specifications for 330851-02-000-060-10-00-CN
-
Manufacturer:Bently Nevada
-
Product Category:Machinery Monitoring Systems
-
Spare Part Number:330851-02-000-060-10-00-CN
-
Weight:0.42 kg
-
Tariff Code:8537101190
-
Transducer family:3300 XL 25 mm
-
Mounting thread:M30×2
-
Overall case length:60 mm
-
Unthreaded-length selection:0 mm
-
Total probe lead:1.0 m
-
Lead armor:None
-
Probe resistance, center to outer:6.2 ± 0.5 Ω
-
Probe tip / case material:PEEK / AISI 304 stainless steel
-
Cable construction:75 Ω triaxial, PFA-insulated FluidLoc
-
Nominal scale factor:0.787 V/mm nominal
-
Nominal linear range:12.7 mm under specified calibration conditions
-
Probe continuous temperature:-35 to +200 °C
Information
- Bently Nevada 330851-02-000-060-10-00-CN places a threaded sensing body at the turbine collar while its short lead connects to a separately selected extension. The installation combines 60 mm mechanical reach with the electrical length required by the remote conditioner.
Integral lead: 1.0 m unarmored FluidLoc cable
Matched-system output: 0.787 V/mm nominal
The 1 m probe lead combines with the appropriate 4 m or 8 m extension cable to form a 5 m or 9 m system using the matching 3300 XL 25 mm Proximitor Sensor. Disconnected probe resistance from center to outer conductor is 6.2 ± 0.5 Ω. Cable and conditioner selection must preserve the complete electrical length.
For the complete matched system, nominal sensitivity is 0.787 V/mm and the linear range is 12.7 mm. The reference conditions include a -24 Vdc supply, a 10 kΩ load, a Bently Nevada AISI 4140 steel target at least 61 mm in diameter, a 7 mm gap and component temperatures from 0 to +45 °C. Probe survivability to +200 °C does not make these reference accuracy conditions universal.
330851-02-000-060-10-00-CN Original Technical Excerpt
Original Bently Nevada pages explain the 25 mm sensing system, calibrated response, materials and applicable cable options. PDF · 6 pages.330851-02-000-060-10-00-CN Installation & Verification Guide
Apter Power field guide covering mechanical and thermal placement, connector protection and displacement verification. PDF · 5 pages.
Application scope: Differential-expansion performance depends on the collar or ramp geometry, target material and configured channel arrangement. Mechanical fit alone does not establish electrical or calibration compatibility.
Mechanical and thermal placement
Confirm the longer threaded reach and keep the Proximitor Sensor within its own lower temperature limit.Turbine collar observation
Measure differential rotor-to-casing growth with a correctly aligned and gapped matched transducer chain.Complementary DE channels
Use opposing collar faces only with the intended two-channel arrangement and corresponding monitor configuration.Controlled displacement verification
Move the probe mounting relative to the target and compare the electrical indication with a mechanical movement reference.
The 1 m probe lead combines with the appropriate 4 m or 8 m extension cable to form a 5 m or 9 m system using the matching 3300 XL 25 mm Proximitor Sensor.
Keep the high-temperature ClickLoc connector clean, finger tight and inside its connector protector.
Use the intended collar or ramp surface and verify the target material against the calibration.
Do not apply probe-body tightening torque to the electrical connector; connector maximum is 0.565 N·m.
Apply probe, cable and Proximitor Sensor temperature limits separately; avoid treating short-term exposure as continuous service.
Test the complete channel through controlled relative movement before restoring the machine protection function.
Alternative Names
Technical notes
Electrical relationship: The 1 m probe lead combines with the appropriate 4 m or 8 m extension cable to form a 5 m or 9 m system using the matching 3300 XL 25 mm Proximitor Sensor. Disconnected probe resistance from center to outer conductor is 6.2 ± 0.5 Ω. Cable and conditioner selection must preserve the complete electrical length.
Measurement boundary: For the complete matched system, nominal sensitivity is 0.787 V/mm and the linear range is 12.7 mm. The reference conditions include a -24 Vdc supply, a 10 kΩ load, a Bently Nevada AISI 4140 steel target at least 61 mm in diameter, a 7 mm gap and component temperatures from 0 to +45 °C. Probe survivability to +200 °C does not make these reference accuracy conditions universal.
Technical reference: Bently Nevada 3300 XL 25 mm Proximity Transducer System, 163236 Rev. M.
FAQ View All FAQ
-
How does 330851-02-000-060-10-00-CN connect a one-metre probe to a five-metre system?Combine the 1.0 m probe lead with the matching 4.0 m extension cable and 5 m 3300 XL 25 mm Proximitor Sensor. The cable lengths form the calibrated chain; the 60 mm case is a separate mechanical dimension.
-
Which clearance matters when positioning the 60 mm body of 330851-02-000-060-10-00-CN?Check M30×2 thread engagement, target gap and clearance behind the case for the lead. The 000 selection gives zero unthreaded length, while the sensing gap is set relative to the target independently.
-
Why can a steel target of the wrong grade change the response of 330851-02-000-060-10-00-CN?Standard system calibration uses Bently Nevada AISI 4140 steel. A different material can change the eddy-current response, so the stated scale factor and accuracy must not be transferred without the appropriate calibration.
-
Does the 25 mm sensing tip of 330851-02-000-060-10-00-CN require a larger flat target?Yes. The reference flat target is at least 61 mm in diameter. Confirm the collar surface and surrounding clearance before applying the nominal matched-system performance.
-
How can moisture protection be maintained around the lead joint of 330851-02-000-060-10-00-CN?Keep the ClickLoc joint clean and fit its connector protector. FluidLoc cable and front/rear probe seals reduce moisture migration; the protected system remains non-submersible.
-
Which reading should an isolated continuity check of 330851-02-000-060-10-00-CN produce?The 1.0 m probe has 6.2 ± 0.5 Ω resistance from centre to outer conductor. Measure it separately from the extension cable so the additional cable resistance does not obscure the probe result.
-
Can the high-temperature probe rating of 330851-02-000-060-10-00-CN be applied to its remote conditioner?No. The probe operates from -35 to +200 °C, whereas the Proximitor Sensor operates from -51 to +100 °C. Place each component within its own temperature limits.
-
What confirms the correct signal direction after fitting 330851-02-000-060-10-00-CN?Move the target or probe mounting by a known amount and compare the output and monitor indication. Verify the configured collar geometry and channel direction before restoring the protection function.
Supporting new and legacy automation
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-
We can't find any results for “”.
You May Also Like
Product Browsing History
-
Whatsapp: +86 18030235313
Send us a message. -
sales13@apterpower.com
Complete our online form. -
+86 18030235313
Speak to our team in your native language.