Match the complete marking
Include 330130-085-00-02 and any revision or approval marking visible on the item. Keep the exact complete reference on your enquiry and quotation.
-
Check the offered item before ordering
Request clear photos of the both coaxial ends and the complete cable marking for 330130-085-00-02. Have your maintenance team compare the offered reference with the installed equipment and applicable Bently Nevada 3300 XL 8 mm documentation.
Technical specifications for 330130-085-00-02
-
Manufacturer:Bently Nevada
-
Product Category:Machinery Monitoring Systems
-
Spare Part Number:330130-085-00-02
-
Weight:0.12 kg
-
Tariff Code:8537101190
-
Cable family:3300 XL 8 mm standard extension
-
Selected cable length:8.5 m (085)
-
Cable construction:Standard cable (00); no armor
-
Matching example:0.5 m probe + 8.5 m cable = 9 m chain
-
Center-conductor resistance:1.87 ±0.28 Ω at 8.5 m
-
Shield-conductor resistance:0.56 ±0.11 Ω at 8.5 m
-
Extension capacitance:69.9 pF/m typical
-
Extension temperature:-52 to +177 °C
-
Matched 9 m system linear span:2.0 mm; approx. 0.25–2.3 mm gap
-
Matched 9 m system ISF:7.87 V/mm ±6.5% at 0–45 °C
-
Matched-system gap reference:Approx. 1.27 mm or -9 Vdc
-
Field-wire recommendation:Three-conductor shielded triad
-
Proximitor-to-monitor field wire:Maximum 305 m; frequency response varies
-
Terminal approval suffix:02; confirm actual marking and site approval
Information
- Bently Nevada 330130-085-00-02 carries the probe signal between an 8 mm sensing tip and the matching Proximitor in a long-reach 3300 XL installation.
System example: 0.5 m probe plus 8.5 m extension for 9 m total
Connection review: inspect both coaxial ends before service
The manufacturer provides separate center and shield resistance guidance for this length. A controlled disconnected-cable check can distinguish a damaged conductor or contaminated joint from a sensor or monitor fault.
Route the cable away from sharp edges and high-heat surfaces while preserving shield integrity. After fitting, establish the correct probe gap and compare the live signal with the machine baseline. The terminal 02 suffix requires confirmation against the actual supplied marking.
-
Bently Nevada 3300 XL 8 mm Proximity Transducer System Datasheet, 141194 Rev. AN
Original manufacturer technical data; use the ordering and system limits applicable to the complete offered code. -
Apter Power 330130-085-00-02 field workflow
Three-page installation, interface, fault-isolation and acceptance guide for the offered model.
Application boundary: The cable supports a measurement chain; the chosen probe, target and monitor determine the actual vibration or position use.
-
Long cable run
Bridge the machine-mounted probe to a remote Proximitor location while preserving the 9 m electrical length. -
Radial-vibration channel
Carry the gap-dependent probe signal to the sensor on a radial shaft measurement point; route away from moving machinery. -
Axial-position channel
Retain the selected length while a thrust-position probe is connected; verify the target and monitor scale separately. -
Cable-fault isolation
Use disconnected center and shield resistance checks to identify a conductor fault before replacing the probe or sensor.
Place the measurement channel in the approved maintenance state before breaking the coaxial connection.
Confirm the probe and Proximitor are both 3300 XL 8 mm components with the selected cable length included in the total.
Inspect the connector faces and any selected protector; avoid trapped dirt or liquid at the mating surfaces.
Secure the 8.5 m standard cable against vibration, abrasion and tight bends without placing tension on either connector.
Check disconnected center and shield continuity separately before replacing a sensor for an apparent signal fault.
After connection, verify the static gap and channel trend; preserve the original alarm configuration until the measurement is accepted.
Alternative Names
Technical notes
System matching: This 8.5 m cable is an electrical component of a 9 m 3300 XL 8 mm chain when paired with a compatible 0.5 m probe and matching Proximitor.
Order-code boundary: The terminal 02 suffix is not decoded by the current 141194 ordering table; verify the actual supplied marking and the site approval before use.
Technical reference: Bently Nevada 3300 XL 8 mm Proximity Transducer System Datasheet, 141194 Rev. AN.
FAQ View All FAQ
-
How is 330130-085-00-02 matched to the installed Proximitor length?Add its 8.5 m electrical length to a compatible 0.5 m probe lead and compare the total with the 9 m Proximitor marking. Do not treat a physically mating connector as proof of a matched chain.
-
What can cause a gap shift after installing 330130-085-00-02?A damaged center conductor, contaminated coaxial contact, changed target or incorrect chain length can shift the DC gap. Isolate the cable, inspect both ends and compare continuity with the manufacturer resistance guidance before adjusting the probe.
-
How should the connector of 330130-085-00-02 be checked before service?Inspect the coaxial center contact, outer contact and mating surfaces for damage or contamination. The standard 00 cable option has no connector protector. Reconnect according to the manufacturer procedure and recheck the static gap voltage.
-
Why can 330130-085-00-02 affect high-frequency response while DC output remains plausible?The cable contributes to the tuned probe-chain electrical length. A wrong extension, changed field wiring or load can alter frequency response; compare the complete chain with the installed monitor configuration.
-
How should 330130-085-00-02 be routed beside other instrument wiring?Protect the cable from crushing, sharp edges, heat and conductive contamination. Preserve shielding and separation required by the machine drawing, then inspect the full route after fastening.
-
Can 330130-085-00-02 be interchanged with an adjacent proximity-system family?Do not mix 3300 XL 8 mm, NSv or 7200 components solely because connectors mate. Match the exact probe family, extension and Proximitor design and confirm the channel calibration before commissioning.
-
What check distinguishes a cable fault from a sensor fault on 330130-085-00-02?With the channel safely isolated, measure continuity and shield path on the disconnected extension and compare the result with the length-specific manufacturer guidance. Reconnect a verified cable and repeat the gap test before replacing the Proximitor.
-
What should be recorded after replacing 330130-085-00-02?Record its complete order code, mated probe and Proximitor identities, cable route, continuity result and the before/after gap voltage. Compare the running channel trend with the approved baseline.
Supporting new and legacy automation
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-
We can't find any results for “”.
Related cases and sourcing guidance
View all case studiesYou May Also Like
Product Browsing History
-
Whatsapp: +86 18030235313
Send us a message. -
sales13@apterpower.com
Complete our online form. -
+86 18030235313
Speak to our team in your native language.