Speak to a sourcing specialist
sales13@apterpower.com
Get a quick price for 330130-080-02-05
E-mail *
Mobile *
Company
Content *
Quantity *
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy

What happens after you enquire

  • 1

    Requirement review

    We review the part number, quantity and delivery requirements and ask for any missing details.
  • 2

    Quotation and availability

    We confirm the proposed item, condition, availability, price and estimated lead time in the quotation.
  • 3

    Order confirmation and dispatch

    Once the quotation and purchasing details are agreed, your contact will coordinate the order and available dispatch information.

Technical specifications for 330130-080-02-05

  • Manufacturer:
    Bently Nevada
  • Product Category:
    Machinery Monitoring Systems
  • Spare Part Number:
    330130-080-02-05
  • Estimated shipping dimensions:
    22x19x3cm
  • Weight:
    0.28 kg
  • Tariff Code:
    8537101190
  • Counliy of origin:
    USA
  • Cable length:
    8.0 m
  • Cable execution:
    Standard FEP
  • Connector protector:
    Included
  • Agency approvals:
    CSA, ATEX and IECEx
  • Cable impedance:
    75 Ohm triaxial
  • Minimum bend radius:
    25.4 mm

Information

Overview Manuals Common Applications Product Precautions
Bently Nevada 330130-080-02-05 is an 8.0 m 3300 XL extension cable with a connector protector. It completes the matched cable length between an 8 mm probe and Proximitor Sensor.
  • Extends the 3300 XL 8 mm probe connection
  • Completes the selected Proximitor system length
  • Carries the eddy-current signal through a triaxial cable
  • Protects the field connector during industrial installation

330130-080-02-05 installs with 3300 XL 8 mm proximity probe, 330180 Proximitor Sensor, ClickLoc connectors, approved cable supports in an engineered 3300 XL 8 mm Proximity Transducer System configuration.

The commissioning workflow covers installed-hardware matching, controlled start-up and functional verification for this 3300 xl 8 mm extension cable.

Important Notice: Confirm the complete 330130-080-02-05 marking, installed-system configuration, field connections and controlled functional test before commissioning or replacement.

Apter Power 330130-080-02-05 Manuals and Guides
Apter Power 330130-080-02-05 Product Technical Reference PDFBently Nevada 330130-080-02-05 Official Manual PDF
The first document is an Apter Power model-specific technical reference. The second supports model-specific installation, configuration and engineering verification.
Remote Proximitor cabinet connectionExtends the 3300 XL 8 mm probe connection
Turbine bearing probe extensionCompletes the selected Proximitor system length
Compressor proximity-signal routingCarries the eddy-current signal through a triaxial cable
Hazardous-area matched cable systemProtects the field connector during industrial installation
Read the applicable Bently Nevada installation instructions before work. Verify 330130-080-02-05 and the installed 3300 XL 8 mm Proximity Transducer System configuration.
1Verify 330130-080-02-05 and the 8.0 m tag before installation.
2Isolate the associated monitor input.
3Inspect cable jacket, connector protector, and contacts.
4Do not pull or twist the cable by its ClickLoc connector.
5Maintain the published bend radius across the complete route.
6Match probe plus extension to the Proximitor system length.
7Keep both connectors clean, dry, and mechanically unloaded.
8Verify continuity, gap voltage, and dynamic response after reconnection.

Technical notes

Confirm probe length plus 8.0 m extension equals the Proximitor system length, maintain the 25.4 mm bend radius, and verify connector cleanliness, continuity, gap voltage, and response.

FAQ View All FAQ

  • How should the field connections for 330130-080-02-05 be recorded before replacement?
    Record terminal or connector identity, polarity, shield, cable tag, channel assignment, and the as-found diagnostic state before disconnecting 330130-080-02-05.
  • What isolation is required before installing 330130-080-02-05?
    Place remote proximitor cabinet connection in the approved maintenance state, isolate every applicable power, signal, and stored-energy source, and prove the work area safe.
  • Which configuration check is essential when commissioning 330130-080-02-05?
    Restore only the approved model-specific channel, range, address, scale, or interface settings and compare them with the physical installation before enabling the process function.
  • How can an engineer function-test 330130-080-02-05 after installation?
    Apply a controlled input, reference, or limited output appropriate to 3300 xl 8 mm extension cable, observe the system indication and diagnostics, and confirm the intended process response.
  • What should be checked if 330130-080-02-05 reports an unstable or incorrect value?
    Check seating, supply, grounding, shielding, matched components, mechanical installation, and the signal path before changing configuration or replacing additional hardware.
  • Can 330130-080-02-05 be replaced by a visually similar model without review?
    No. Verify the complete part number, electrical execution, connector arrangement, companion hardware, and approved software or rack configuration.
  • What commissioning evidence should be retained for 330130-080-02-05?
    Retain the full 330130-080-02-05 identity, as-left wiring and settings, measured functional-test results, final diagnostics, and authorization to return the affected equipment to service.
  • Which installed hardware must be matched before fitting 330130-080-02-05?
    Match the complete 330130-080-02-05 marking to 3300 XL 8 mm proximity probe and 330180 Proximitor Sensor, then confirm the assigned 3300 XL 8 mm Proximity Transducer System position and approved system configuration.
Related reading

Related cases and sourcing guidance

View all case studies