Match the complete marking
Match the complete Bently Nevada 330104-02-09-10-01-00 marking and installed configuration. Compare the probe marking, 90 mm case, 20 mm unthreaded section, M10 x 1 and termination.
-
Check the offered item before ordering
Request available label and connector photos. Have your maintenance team compare the offered 330104-02-09-10-01-00 with the installed equipment and applicable Bently Nevada documents.
Technical specifications for 330104-02-09-10-01-00
-
Manufacturer:Bently Nevada
-
Product Category:Machinery Monitoring Systems
-
Spare Part Number:330104-02-09-10-01-00
-
Weight:0.54 kg
-
Tariff Code:8537101190
-
Sensing principle:Non-contact eddy current
-
Tip diameter:8 mm
-
Mounting thread:M10 x 1
-
Integral lead length:1.0 m
-
Lead construction:armored standard lead with connector protector
-
Probe upper temperature:+177 °C
-
Matched-system scale factor:7.87 V/mm nominal
-
Matched-system linear range:2 mm
-
Default calibration target:AISI 4140 steel
Information
- Bently Nevada 330104-02-09-10-01-00 places the sensing element at the shaft while supporting protected cable routing. A stable mechanical reference and matched electrical chain allow the monitor to distinguish position and vibration.
Adjustment objective: Stable working gap with usable travel
Integration boundary: Probe, extension and conditioner operate as one chain
The 1.0 m integral lead must be combined with the extension required by the selected conditioner. A matched 5 m arrangement uses a 4.0 m extension; this example does not authorize another transducer family or an arbitrary splice. Protect and support the coaxial junction.
Target material, nearby metal and mixed component generations can affect calibration. Verify response across the intended travel, then test the receiving monitor before restoring protection.
330104-02-09-10-01-00 Original Technical Excerpt
Bently Nevada 3300 XL 8 mm Proximity Transducer System, 141194 Rev. AN. Selected original pages retain the relevant technical context. PDF · 6 pages.330104-02-09-10-01-00 Installation & Verification Guide
Apter Power installation workbook covering locate the sensing point, fit the protected cable routing, complete the coaxial chain, validation and handover. PDF · 5 pages.
Application scope: These applications describe the intended system function. Select the actual configuration for that function; accessories are included only when itemized.
Relative shaft vibration
Use protected cable routing at a rigid radial measurement location.Shaft position measurement
Maintain linear travel about the configured working gap.Existing channel restoration
Retain target, calibrated length and monitor assignment.Transducer response checking
Compare controlled gap changes with electrical output.
Record target position, gap and monitor assignment before removal. Compare the 90 mm case, 20 mm unthreaded section with bracket engagement and access at the M10 x 1 interface. Inspect the surrounding conductive material and establish the intended measurement travel before disturbing the reference.
Control the affected protection channel under the site procedure. Fit the probe with clear sensing space and adequate adjustment. Do not pull the 1.0 m lead. Check that securing the mount does not shift the gap or introduce contact with the shaft.
Confirm conditioner system length and select the matching extension. Inspect connector halves and engage ClickLoc finger-tight. Apply protection appropriate to the armored standard lead with connector protector; support the route so service access and machine vibration do not load the connection.
Use controlled known positions and compare conditioner output over the intended span. Retain target material and calibration conditions in the result. Investigate noise, slope or travel-limit differences before changing monitor settings. Apply the accuracy for the actual system length.
Restore monitor configuration and compare the operating gap with the retained reference. Exercise alarm and supervisory functions in the approved test state. Record probe, extension and conditioner identities with accepted results before removing maintenance inhibits.
Retain the final tested settings, physical connections and accepted operating response for 330104-02-09-10-01-00.
Alternative Names
Technical notes
Target-dependent conversion: Apply calibration for the actual target material and geometry. A plausible DC output alone does not establish the correct scale.
Electrical chain integrity: Match integral lead, extension and conditioner length. Support and protect the junction without modifying the calibrated cable.
Channel release: Validate the monitor and required alarm response after accepting the transducer signal; the local probe check covers only part of the path.
FAQ View All FAQ
-
Does armor on 330104-02-09-10-01-00 remove the need for cable support?No. Armor does not eliminate connector loading, bend constraints or routing support.
-
How does the unthreaded section affect mounting 330104-02-09-10-01-00?The bracket must engage actual thread while positioning the tip correctly. Do not treat the whole case as usable thread.
-
Can the protector on 330104-02-09-10-01-00 compensate for a loose connector?No. Establish correct ClickLoc engagement before fitting protection.
-
Why keep the armored lead of 330104-02-09-10-01-00 clear of moving parts?Rubbing can abrade the jacket or load the probe. Armor does not make repeated contact acceptable.
-
What should be checked if 330104-02-09-10-01-00 becomes noisy after conduit work?Review lead strain, connector condition and interference exposure while retaining gap and scaling references.
-
Does an armored lead make 330104-02-09-10-01-00 a FluidLoc execution?No. Armor and fluid-blocking construction are separate options.
-
Why check the monitor after accepting the mounting of 330104-02-09-10-01-00?Correct mounting does not prove scaling or alarm behavior. Validate the electrical and supervisory paths.
-
Can a target coating or surface repair affect 330104-02-09-10-01-00?Yes. Changes in material seen by the field can affect calibration. Reassess the actual target before reusing the conversion.
Supporting new and legacy automation
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-
We can't find any results for “”.
Related cases and sourcing guidance
View all case studiesYou May Also Like
Product Browsing History
-
Whatsapp: +86 18030235313
Send us a message. -
sales13@apterpower.com
Complete our online form. -
+86 18030235313
Speak to our team in your native language.