Speak to a sourcing specialist
sales13@apterpower.com
Get a quick price for 330101-02-70-10-11-05
E-mail *
Mobile *
Company
Content *
Quantity *
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy

What happens after you enquire

  • 1

    Requirement review

    We review the part number, quantity and delivery requirements and ask for any missing details.
  • 2

    Quotation and availability

    We confirm the proposed item, condition, availability, price and estimated lead time in the quotation.
  • 3

    Order confirmation and dispatch

    Once the quotation and purchasing details are agreed, your contact will coordinate the order and available dispatch information.

Technical specifications for 330101-02-70-10-11-05

  • Manufacturer:
    Bently Nevada
  • Product Category:
    Machinery Monitoring Systems
  • Spare Part Number:
    330101-02-70-10-11-05
  • Estimated shipping dimensions:
    Manufacturer shipping dimensions are not published; confirm before shipment.
  • Weight:
    0.1 kg
  • Tariff Code:
    Not specified by manufacturer.
  • Counliy of origin:
    Not specified in official datasheet.
  • Product Type:
    3300 XL 8 mm FluidLoc proximity probe
  • Mounting Thread:
    3/8-24 UNF
  • Armor:
    None
  • Unthreaded Length:
    0.2 in
  • Overall Case Length:
    7.0 in
  • Total Probe Length:
    1.0 m (3.3 ft)
  • Connector and Cable:
    Protected ClickLoc; FluidLoc cable
  • Approval Option:
    05 — CSA, ATEX, IECEx
  • Probe Tip Diameter:
    8.0 mm (0.31 in)
  • System Linear Range:
    2.0 mm (80 mil)
  • System Scale Factor:
    7.87 V/mm (200 mV/mil) ±5%
  • Recommended Radial Gap:
    1.27 mm (50 mil), approximately -9 Vdc
  • Frequency Response:
    0 to 10 kHz, +0/-3 dB
  • Probe Temperature:
    -52°C to +177°C (-62°F to +350°F)
  • Minimum Bend Radius:
    25.4 mm (1.0 in)
  • Minimum Flat Target:
    15.2 mm (0.6 in)

Information

Overview Manuals Common Applications Product Precautions
The 330101-02-70-10-11-05 is a Bently Nevada 3300 XL 8 mm unarmored probe with 3/8-24 UNF threads, 0.2 in unthreaded length, 7.0 in case length, 1.0 m FluidLoc cable, protected ClickLoc connector, and CSA, ATEX, and IECEx approvals option.
  • 3300 XL 8 mm FluidLoc proximity probe
  • 3/8-24 UNF
  • None
  • 0.2 in

It measures probe-to-target distance without contact and uses FluidLoc cable to impede oil migration through the lead while delivering vibration, position, Keyphasor, or speed signals through a matched extension cable and Proximitor Sensor. For dependable measurement, follow the official system-matching, target, mounting, cabling, environmental, and approval instructions.

Important Notice: FluidLoc option 11 and the 7.0 in case are official configurations. Check routing, clearances, system length, and approval markings before installation.

Apter Power 330101-02-70-10-11-05 Original Product Manual

Important Notice: This Apter Power original manual summarizes manufacturer-published technical data for the exact ordering code. Verify the physical nameplate and current manufacturer installation documents before use.

Fluid-Film-Bearing Machinery
Provides non-contacting shaft vibration and position measurements on rotating machinery equipped with fluid-film bearings.
Radial Shaft Vibration
Measures dynamic shaft motion relative to the long 3/8-24 UNF mounting case mounting location.
Static Shaft Position
Measures the static gap between the probe tip and a conductive shaft or target through the complete transducer system output.
Oil-Exposed Cable Routes
FluidLoc construction is intended to reduce oil or liquid migration through the probe cable interior.
Speed Measurement
Supports rotational-speed measurement when system length, target geometry, and monitoring-channel requirements are satisfied.
Machinery Protection
Supplies a conditioned vibration or position signal to a compatible Bently Nevada monitoring system.
Read and follow Bently Nevada 3300 XL 8 mm Proximity Transducer System Datasheet 141194 Rev. AM and the applicable installation instructions before use. Verify the complete ordering code from the physical nameplate and match every component to the published system configuration.
1
Verify that the 7.0 in case clears internal machine structures and does not create side-view interference.
2
Match the 1.0 m probe to a 4.0 m or 8.0 m FluidLoc extension cable for the selected Proximitor Sensor length.
3
Maintain the 25.4 mm bend radius and do not expose the unarmored lead to crushing or abrasion.
4
Gap and test the complete system using the intended target material.
5
Confirm the 05 approval marking and safe-use requirements from the nameplate and current drawings.

Alternative Names

330101 02 70 10 11 05 330101 7 inch FluidLoc probe 330101 protected ClickLoc proximity probe 330101-02-70-10-11-BR 330101-02-70-10-11-RU 330101-02-70-10-11-O5 330101-02-70-10-1I-05 330101-02-70-10-I1-05 330101-02-70-1O-11-05 330101-02-70-I0-11-05 330101-02-7O-10-11-05 330101-O2-70-10-11-05 33010I-02-70-10-11-05 3301O1-02-70-10-11-05 330I01-02-70-10-11-05 33O101-02-70-10-11-05

Technical notes

FluidLoc option 11 and the 7.0 in case are official configurations. Check routing, clearances, system length, and approval markings before installation.

FAQ View All FAQ

  • What is the 330101-02-70-10-11-05?
    It is a long-case 3/8-24 UNF 3300 XL 8 mm probe with a 1.0 m FluidLoc cable and factory connector protector.
  • What do options 02 and 70 specify?
    They define a 0.2 in unthreaded length and a 7.0 in overall probe case.
  • What is the purpose of FluidLoc cable?
    The manufacturer states that FluidLoc construction prevents oil and other liquids from leaking through the cable interior.
  • Which extension cable lengths are compatible?
    Use 4.0 m for a 5 m system or 8.0 m for a 9 m system, with matching FluidLoc construction and compatible Proximitor Sensor.
  • What signals can this probe support?
    The matched system supports shaft vibration, position, Keyphasor reference, and speed measurement.
  • What are the nominal range and scale factor?
    The complete 3300 XL 8 mm system provides 2.0 mm linear range and 7.87 V/mm scale factor ±5%.
  • What must be checked for the 7.0 in case?
    Confirm installed clearance, side-view effects, thread engagement, bend radius, target geometry, and the operating gap.
  • Does option 05 automatically authorize every hazardous-area installation?
    No. It is the approval option, but the physical marking, current certificate, barriers, and installation drawing remain controlling.
Related reading

Related cases and sourcing guidance

View all case studies
SPEAK TO OUR TEAM
Let’s find the right solution for you.
Send us the part number, quantity and delivery destination. Our team will help confirm availability and lead time.
  • Whatsapp: +86 18030235313

    Send us a message.
  • sales13@apterpower.com

    Complete our online form.
  • +86 18030235313

    Speak to our team in your native language.