Speak to a sourcing specialist
sales13@apterpower.com

330101-00-20-10-12-05

3300 XL 8 mm proximity probe
In Stock
Product image is representative; revision or series may vary. Contact us to request a specific version.

Product Describe:

Bently Nevada 330101-00-20-10-12-05 is a compact 3/8-24 probe with a 2.0 in case and 1.0 m unarmored FluidLoc lead for a matched 3300 XL 8 mm channel.
  • Manufacturer part number
    330101-00-20-10-12-05
  • Shipping
    Swift global dispatch
  • Condition
    New, original product
  • Shipping size (est.)
    1.6cm x 1.3cm x 112cm
  • Country of Origin
    USA
Get a quick price for 330101-00-20-10-12-05
E-mail *
Mobile
Company
Content *
Quantity *
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy

What happens after you enquire

  • 0

    Review your reference

    Send the full marking, quantity and label photos. We review the item and any version details that need clarification.
  • 1

    Confirm the offer

    Check the quoted reference, condition, included items and expected dispatch date before approving your order.
  • 2

    Arrange dispatch

    Confirm delivery details and receive the tracking number when it becomes available.
  • Match the complete marking

    Include 330101-00-20-10-12-05 and every revision or approval marking visible on the item. Keep the exact reference on your enquiry and quotation.
  • Check the offered item before ordering

    Request available label and interface photos. Have your maintenance team compare the offered 330101-00-20-10-12-05 reference with the installed equipment and applicable Bently Nevada documentation.

Technical specifications for 330101-00-20-10-12-05

  • Manufacturer:
    Bently Nevada
  • Product Category:
    Machinery Monitoring Systems
  • Spare Part Number:
    330101-00-20-10-12-05
  • Weight:
    0.05 kg
  • Tariff Code:
    8537101190
  • Probe family:
    3300 XL 8 mm
  • Mounting thread:
    3/8-24 UNF-2A
  • Cable armor:
    No armor
  • Unthreaded length:
    0.0 in
  • Overall case length:
    2.0 in
  • Total probe length:
    1.0 m
  • Connector:
    Miniature ClickLoc, FluidLoc cable without protector
  • Approval selection:
    Multiple approvals
  • Nominal probe resistance:
    5.9 +/-0.5 ohm
  • Matched-system range:
    2.0 mm under stated reference conditions
  • Matched-system scale:
    7.87 V/mm (200 mV/mil)
  • Proximitor supply:
    -17.5 to -26 V DC; 12 mA maximum without barriers
  • Proximitor output resistance:
    50 ohm
  • Reference target:
    AISI 4140 steel
  • Measurement roles:
    Static position, dynamic vibration, phase reference and speed

Information

Overview Downloads Applications / Compatibility Product Precautions
  • Bently Nevada 330101-00-20-10-12-05 is a compact 3/8-24 probe with a 2.0 in case and 1.0 m unarmored FluidLoc lead for a matched 3300 XL 8 mm channel.
Selected geometry: 3/8-24 UNF-2A; 0.0 in unthreaded reach; 2.0 in overall case.
Lead construction: 1.0 m lead with unarmored cable; Miniature ClickLoc, FluidLoc cable without protector.
Diagnostic reference: 5.9 +/-0.5 ohm nominal probe resistance; Multiple approvals.
The 2.0 in body of 330101-00-20-10-12-05 suits compact inch-thread ports where the sensing face must be established from a short bracket or sleeve. The removal datum remains more important than the family name because adjacent 330101 case codes position the tip differently.

Option 12 selects an unarmored FluidLoc lead without a connector protector. Its liquid-resistant cable construction addresses the lead itself; it does not remove the need to keep the ClickLoc joint dry, supported and outside direct spray.

A clean isolated resistance check can help separate probe and cable faults, but acceptance belongs to the complete chain. Restore the recorded gap or bias, verify stable output after routing and compare the monitor with the machine baseline.
Controller platform reference: 3300 XL 8 mm system. Confirm the exact geometry, total electrical length and restored channel response before release.
Technical downloads for Bently Nevada 330101-00-20-10-12-05: model-specific technical reference and installation review.
Use the exact order code and installed configuration when applying either document.
Prepare Bently Nevada 330101-00-20-10-12-05 using the approved machine documentation and site procedure.
Confirm the 2.0 in tip datum

Measure port depth and locknut position before replacing another 3/8-24 case length.

Do not confuse FluidLoc with a sealed joint

The cable construction is liquid resistant, but the ClickLoc interface still requires a dry protected location.

Support the unarmored lead

Prevent abrasion and tensile load along the 1.0 m route.

Keep chemicals off the connector

Route the joint away from direct spray and inspect both mating surfaces before connection.

Reconcile cable option 12

Check the full marking so a standard-cable or protector variant is not accepted by appearance.

Stabilize output after routing

A bias shift after clamping can indicate cable stress, connector contamination or changed gap.

Alternative Names

Bently Nevada 330101-00-20-10-12-05 3300 XL 8 mm proximity probe 330101-00-20-10-12-05

Technical notes

Mechanical datum: Match 0.0 in unthreaded reach and 2.0 in case to the port depth, bracket position and expected target travel.

Electrical chain: Use the 1.0 m probe lead only with the extension cable and Proximitor that reproduce the installed total length.

Resistance and response: Use 5.9 +/-0.5 ohm only as an isolated diagnostic reference; gap and dynamic acceptance still require the complete channel.

FAQ View All FAQ

  • What installation benefit does the 2.0 in case provide for 330101-00-20-10-12-05?
    It fits compact 3/8-24 brackets while preserving a short, documented sensing-face datum; the actual port depth and target travel still govern seating.
  • What does FluidLoc option 12 change on 330101-00-20-10-12-05?
    It selects the liquid-resistant probe cable without a connector protector, so the lead construction differs from standard option 02 and protected option 11.
  • Can the ClickLoc of 330101-00-20-10-12-05 be placed in direct process spray?
    No assumption should be made from the FluidLoc name; keep the joint clean, dry and mechanically supported in the approved enclosure or route.
  • How should a bias change after routing 330101-00-20-10-12-05 be investigated?
    Release cable strain, inspect the unprotected ClickLoc, reconfirm the gap and compare the probe resistance before disturbing the extension cable or Proximitor.
  • Why is option 02 not equivalent to option 12 on 330101-00-20-10-12-05?
    Option 02 is standard cable, whereas option 12 is FluidLoc; the route and exposure controls must follow the delivered construction.
  • Which mechanical record is most important before removing 330101-00-20-10-12-05?
    Capture the 2.0 in body seating, locknut position, target clearance and lead exit direction so the compact datum can be restored.
  • How is the complete channel accepted after installing 330101-00-20-10-12-05?
    Reconcile total electrical length, restore gap or bias, secure the FluidLoc route and compare static and controlled monitor response with the baseline.
  • What evidence distinguishes 330101-00-20-10-12-05 at handover?
    Retain the full option-12 marking, connector protection arrangement, 2.0 in seating datum, lead route, as-left bias and channel proof.
SPEAK TO OUR TEAM
Let’s find the right solution for you.
Send us the part number, quantity and delivery destination. Our team will help confirm availability and lead time.
  • Whatsapp: +86 18030235313

    Send us a message.
  • sales13@apterpower.com

    Complete our online form.
  • +86 18030235313

    Speak to our team in your native language.