Match the complete marking
Include the complete 330106-05-30-05-02-05 reference and identify the installed reverse-mount sleeve, probe lead length and Proximitor.
-
Check the offered item before ordering
Request label, tip and connector photographs. Have your maintenance team compare the offered 330106-05-30-05-02-05 with the installed reverse-mount probe and applicable Bently Nevada 3300 XL instructions.
Technical specifications for 330106-05-30-05-02-05
-
Manufacturer:Bently Nevada
-
Product Category:Machinery Monitoring Systems
-
Spare Part Number:330106-05-30-05-02-05
-
Weight:0.04 kg
-
Tariff Code:8537101190
-
Mounting arrangement:Reverse mount
-
Case thread:M10 × 1
-
Tip diameter:8 mm
-
Unthreaded length:5 mm
-
Case length:30 mm
-
Total probe length:0.5 m
-
Lead impedance:75 Ω
-
Lead construction:Standard FEP-insulated triaxial
-
Connector:Miniature male ClickLoc coaxial
-
Probe tip material:Polyphenylene sulfide
-
Case material:AISI 303 or 304 stainless steel
-
Recommended reverse-mount torque:7.5 N·m
-
Maximum rated reverse-mount torque:22.6 N·m
-
Case-to-lead tensile limit:330 N maximum rated
-
Probe-to-extension junction tensile limit:270 N maximum rated
-
Nominal probe resistance:7.45 Ω ±0.50 Ω; centre to outer conductor
-
Operating and storage temperature:−52 to +177 °C
-
Cold pressure-seal caution:Possible premature failure below −34 °C
-
XL-to-XL connection method:Finger tight
-
Default system target calibration:AISI 4140 steel
Information
- Bently Nevada 330106-05-30-05-02-05 locates the sensing tip through a reverse-mount probe arrangement rather than a conventional forward-mounted case. The sleeve interface, final tip position and short electrical lead must be reviewed together when restoring the measurement point.
Short signal connection: The probe lead joins the selected extension close to the machine-side installation.
Relative-position measurement: The matched eddy-current system observes target movement relative to the secured probe tip.
Reverse-mount probes are not offered with armor or a connector-protector option. The short standard lead therefore needs a route that protects the junction without transferring cable loads to the case. Use the tightening recommendation for reverse mounting; a forward-mount torque value is not interchangeable merely because both cases have metric threads.
The probe functions within a matched transducer system. A compatible extension and Proximitor must agree with its 0.5 m electrical contribution, while target material and operating gap determine the installed response. Verify the final gap and a controlled physical response after the sleeve, cable support and connector are in their service positions.
330106-05-30-05-02-05 Official Reverse-Mount Probe Excerpt
Original English reverse-mount ordering and drawing, probe materials, mechanical limits and complete-system performance conditions. PDF · 10 pages.330106-05-30-05-02-05 Installation & Verification Guide
Apter Power workbook for 330106-05-30-05-02-05, covering sleeve fit, short-lead routing, correct tightening and assembled-channel acceptance. PDF · 5 pages.
Application scope: Apply the reverse-mount geometry and torque requirements to the installed position. System compatibility also requires the correct electrical length, target calibration and marked installation conditions.
Reverse-mount measurement positions
Locate the sensing element through a sleeve designed for the metric reverse-mount probe.Short-lead transducer junctions
Join a compatible extension near the probe while preserving supported connector access.Shaft-relative vibration channels
Measure conductive-target motion through a compatible conditioned eddy-current path.Installed position-channel restoration
Restore the existing mechanical reference and calibrated response after probe or sleeve service.
Compare the 5 mm unthreaded and 30 mm case dimensions with the actual sleeve.
Use the appropriate recommendation and keep maximum rated torque distinct.
Avoid loading the connector or assuming an armor option is fitted.
Inspect the sleeve and machine containment design independently of temperature compliance.
Verify probe, extension and Proximitor before setting gap.
Check end-to-end response after all mechanical and cable work is complete.
Alternative Names
Technical notes
Order-format distinction: The fixed reverse-mount geometry must not be interpreted using the forward-mount case-length increments.
Mechanical reference: Changing sleeve position can change the observed gap even if the probe and monitor remain electrically healthy.
Continuity boundary: Probe resistance is a diagnostic check; it does not establish the target calibration or final monitor scale.
FAQ View All FAQ
-
Why must the geometry of 330106-05-30-05-02-05 be checked differently from a forward-mount probe?The reverse-mount format has fixed geometry shown in its drawing. Use that drawing and the sleeve interface; applying the forward-mount increment rule can produce a mechanically incorrect selection.
-
Can the normal forward-mount tightening value be applied to 330106-05-30-05-02-05?No. Reverse mounting has its own recommendation and maximum rated limit. Use the reverse-mount requirement, then recheck final tip position and conditioned gap after securing the assembly.
-
What should be examined if the gap changes after the sleeve holding 330106-05-30-05-02-05 is serviced?Check sleeve position, case seating, target clearance and loads from the short lead. A mechanical reference change can affect the same gap signal as shaft movement; verify the installation before changing monitor scaling.
-
Could an armored forward-mount probe replace 330106-05-30-05-02-05 solely because its lead length matches?No. Matching electrical length does not establish reverse-mount sleeve fit or case geometry. Review the mechanical mounting architecture separately from the compatible transducer chain.
-
Does the sleeve around 330106-05-30-05-02-05 make a connector-protection inspection unnecessary?No. The reverse-mount option does not include an armor or connector-protector selection. Inspect the actual junction exposure and approved routing instead of assuming the sleeve protects every cable interface.
-
How should 330106-05-30-05-02-05 be evaluated when a continuity check passes but dynamic response is wrong?Confirm the complete electrical chain, actual target material, operating gap and monitor configuration. Use a controlled displacement comparison; continuity alone cannot identify a scale or calibration mismatch.
-
Can the low-temperature operating rating of 330106-05-30-05-02-05 be used as proof of pressure sealing?No. Pressure-seal performance has a separate caution below −34 °C, and probes are not pressure-tested before shipment. Establish containment requirements for the actual application independently of electrical operation.
-
Why should the final test of 330106-05-30-05-02-05 include the installed sleeve and cable supports?Those parts define probe position and mechanical loading. A loose bench test does not reproduce the finished reference. Verify gap and response after the sleeve and short-lead junction are secured.
Supporting new and legacy automation
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-
We can't find any results for “”.
Related cases and sourcing guidance
View all case studiesYou May Also Like
Product Browsing History
-
Whatsapp: +86 18030235313
Send us a message. -
sales13@apterpower.com
Complete our online form. -
+86 18030235313
Speak to our team in your native language.