Technical specifications for 3300/48-03-02-00-00
-
Manufacturer:Bently Nevada
-
Product Category:Machinery Monitoring Systems
-
Spare Part Number:3300/48-03-02-00-00
-
Weight:1.08 kg
-
Tariff Code:8537101190
-
Monitor function:Two-channel casing expansion
-
Full-scale range:0–2 in.
-
Transducer input:2 in. DC LVDT; 10 mV/mil
-
Alarm relay option:No relays
-
Agency approval option:00 — Not required
-
Signal input impedance:1.0 megohm
-
Nominal power consumption:1.5 W
-
Signal-conditioning accuracy:±0.33% FS typical; ±1% FS maximum at +25°C
-
Recorder formats:4–20 mA; 1–5 Vdc; 0 to -10 Vdc
-
Alarm measurement:Differential mode only
-
Operating temperature:0 to +65°C
-
Relative humidity:Up to 95%, noncondensing
Information
- Bently Nevada 3300/48-03-02-00-00 serves existing 3300 rack installations. A two-inch casing-growth installation uses separate channel readings to distinguish overall motion from unequal movement at the supports.
Transducer match: 2 in. DC LVDT; 10 mV/mil
Relay configuration: No relays
Alarm basis: Differential casing movement
Alert and Danger levels are adjustable over 0–100% of full-scale in Differential mode. Display and setting resolution is within ±1.6% of full-scale; alarm repeatability after adjustment is within ±0.4% of full-scale. No relays is the ordered relay configuration. Delay, reset and energized-state settings remain separate commissioning choices that must match the rack alarm arrangement.
Recorder outputs can be configured for 4–20 mA, 1–5 Vdc or 0 to -10 Vdc, with two direct channels or one differential measurement. A current output supports 0–600 ohms; a voltage output requires at least 10 kilohms. Buffered transducer connections support signal inspection, while the LCD and OK indicators provide adjustment and diagnostic information.
-
Bently Nevada 3300/48-03-02-00-00 technical reference
Original manufacturer excerpt - PDF, 4 pages. Monitor option identification, reading setpoints, self-tests and diagnostic indications. -
Bently Nevada 3300/48-03-02-00-00 installation guide
Prepared by Apter Power - PDF, 5 pages. Configuration review, signal connections, alarm settings, commissioning and handover.
Integration boundary: Coordinate the machine mounting arrangement, recorder scaling and rack alarm logic. A matching family name alone does not establish an interchangeable range, input sensitivity or relay module.
-
Casing growth
Track movement of the casing relative to the machine foundation using two DC LVDTs. -
Unequal movement
Use the differential measurement to compare displacement at the two monitored locations. -
Rack alarm circuits
Provide the required system relay arrangement for this no-relay option. -
Trend recording
Scale the selected current or voltage recorder signal to the 0–2 in. monitor range.
Use 2 in. dc lvdt; 10 mv/mil inputs with the 0–2 in. scale.
Alert and Danger comparisons are available only in Differential mode.
The order specifies no relays; verify the actual rear module and downstream contact circuit.
Use 0–600 ohms for 4–20 mA or at least 10 kilohms for a voltage output.
Record delay, reset, energized state, recorder mode and upscale direction before replacement.
Resolve active error indications and verify both channels before returning the measurement to service.
Alternative Names
Technical notes
Measurement relationship: The LVDTs measure casing displacement relative to the foundation. This is not a rotor differential-expansion probe measurement.
Alarm configuration: No relays is the ordered relay option. Alert and Danger comparisons operate only in Differential mode; verify relay wiring, reset behavior and delay before service.
Technical reference: Bently Nevada 3300/48 Specifications and Ordering Information, 141510-01 Rev. F; Case Expansion Monitor Operation, 84417-01 Rev. NC. The original operation excerpt covers option identification, setpoint reading and self-test indications.
FAQ View All FAQ
-
How are the range and sensitivity selected for 3300/48-03-02-00-00?Range option 03 is 0–2 in., paired with input option 02 for a 2 in. DC LVDT at 10 mV/mil. Preserve the inch display range and matching transducer sensitivity during replacement.
-
How does 3300/48-03-02-00-00 distinguish casing movement from rotor expansion?Its inputs are DC LVDTs mounted to measure casing movement relative to the foundation. It is a casing-expansion monitor, so its signal arrangement must not be substituted for a rotor differential-expansion measurement.
-
How accurately does 3300/48-03-02-00-00 condition the expansion signal?At +25°C, signal-conditioning error is typically within ±0.33% of full-scale and no more than ±1% of full-scale. Recorder-output error is additional and depends on the chosen current or voltage format.
-
Can the recorder mode of 3300/48-03-02-00-00 be changed independently of the displayed channels?The recorder selection provides two direct measurement channels or one differential measurement channel. Check the recorder jumpers and receiving-system scaling separately from the front-panel display selection.
-
How are differential alarm levels adjusted on 3300/48-03-02-00-00?Alert and Danger are digitally adjustable from 0–100% of full-scale. Setting resolution is within ±1.6% of full-scale, and alarm repeatability after setting is within ±0.4% of full-scale.
-
Which alarm delays are available on 3300/48-03-02-00-00?The field-programmable delay choices are 0.1, 1, 3 or 6 seconds. Select and verify the delay against the machine monitoring plan instead of assuming the installed unit retains a factory setting.
-
Does 3300/48-03-02-00-00 include local alarm relay contacts?No. Its relay option is 00. A system-level alarm relay arrangement is required where contact outputs are needed; verify the relay bus programming and rear signal-input module together.
-
What environmental conditions apply to 3300/48-03-02-00-00?The specified operating range is 0 to +65°C, storage range is -40 to +85°C, and relative humidity is up to 95% without condensation. The final 00 option does not request an agency approval.
Supporting new and legacy automation
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-
We can't find any results for “”.
You May Also Like
Product Browsing History
-
Whatsapp: +86 18030235313
Send us a message. -
sales13@apterpower.com
Complete our online form. -
+86 18030235313
Speak to our team in your native language.