Match the complete marking
Include 3300/14-01-20-00 and any revision or assembly number visible on the item. Keep the exact reference on your enquiry and quotation.
-
Check the offered item before ordering
Request available label and connector photos for 3300/14-01-20-00. Have your maintenance team compare the offered reference with the installed equipment and applicable Bently Nevada documentation.
Technical specifications for 3300/14-01-20-00
-
Manufacturer:Bently Nevada
-
Product Category:Machinery Monitoring Systems
-
Spare Part Number:3300/14-01-20-00
-
Weight:2.4 kg
-
Tariff Code:8537101190
-
Product type:DC Power Supply
-
Complete order number:3300/14-01-20-00
-
Input voltage option:20–34 Vdc (01)
-
Maximum input current:5.5 A
-
Power Input Module:Standard Power Input Module (20)
-
Agency approval selection:No agency approval required (00)
-
Rack position:Position 1, leftmost slot beside the System Monitor
-
Rack supply capacity:Up to 12 monitors and associated transducers
-
Transducer supply selection:-24 Vdc (+1.3%/-1.7%) or -18 Vdc (+1.6%/-2.2%)
-
Output selection method:Jumper selection on the Power Supply PWA
-
Overload protection:Individual channels on monitor circuit boards
-
OK relay:Hermetically sealed SPDT; normally energized
-
OK relay location:Power Input Module behind the Power Supply
-
Relay operating life:10,000 cycles minimum at rated load
-
General operating temperature:0 to +65 °C; approval conditions may be more restrictive
-
Storage temperature:-40 to +85 °C
-
Relative humidity:95%, noncondensing
-
Nominal input:+26 Vdc
-
Input-range protection:Shuts down outside the input range; resumes when the input returns within range
Information
- Bently Nevada 3300/14-01-20-00 supports regulated rack and transducer power in a matched 3300 machinery monitoring system.
Ordered input: 20–34 Vdc
Power input arrangement: Standard Power Input Module
The supply occupies the leftmost rack position beside the System Monitor and powers up to 12 monitors plus their associated transducers. A jumper on the Power Supply PWA selects -24 Vdc (+1.3%/-1.7%) or -18 Vdc (+1.6%/-2.2%). Overload protection is provided for each individual channel on the monitor circuit boards; the chosen transducer supply must match the installed channels.
A normally energized, hermetically sealed SPDT OK relay is located on the Power Input Module behind the supply. Bently Nevada recommends an external annunciator because loss of primary power, monitor function or critical wiring can compromise machinery protection. Review the System Monitor, backplane and monitor firmware together. A 3300/14 used with an Original backplane requires an Original Power Input Module, and it is not compatible with the 3300/01-02 System Monitor. Approval option 00 does not specify an agency approval. Assess any hazardous-area requirement at the complete installed-system level.
-
Bently Nevada 3300/14-01-20-00 technical reference
Original manufacturer technical excerpt — PDF, 3 pages, 153.2 KB. Power-supply functions, electrical characteristics and ordering options. -
Bently Nevada 3300/14-01-20-00 installation planning guide
Prepared by Apter Power — PDF, 5 pages, 25.8 KB. Rack compatibility, power selection, controlled replacement planning and acceptance checks.
Platform applications: These applications describe 3300 rack-power functions. Match the System Monitor, backplane, monitor firmware and approval conditions before replacement.
-
3300 rack power
Supply a matched 3300 monitoring rack from 20–34 Vdc. One supply supports up to 12 monitors and their associated transducers. -
Transducer supply selection
Select the -24 Vdc or -18 Vdc transducer supply through the Power Supply PWA jumper. Match the selection to the installed monitors and transducers. -
Rack fault annunciation
Connect the normally energized OK relay to an external annunciator under the approved rack wiring design. A loss of primary power or monitoring integrity must be visible to operators. -
Power-input integration
Use the standard Power Input Module with the specified supply and compatible rack backplane. Review the System Monitor and monitor firmware before replacement.
Check 20–34 Vdc, maximum input current 5.5 A, and the actual module configuration before connecting power. Observe DC polarity and the permitted input range.
Review the System Monitor, backplane and monitor firmware together. A 3300/14 used with an Original backplane requires an Original Power Input Module, and it is not compatible with the 3300/01-02 System Monitor.
Standard Power Input Module is the ordered selection. Confirm the actual rear module and field wiring; do not interchange backplane generations without the applicable compatibility review.
Verify the -18 Vdc / -24 Vdc jumper against the installed transducers and monitoring channels. A supply replacement must preserve the intended channel configuration.
Approval option 00 does not specify an agency approval. Assess any hazardous-area requirement at the complete installed-system level.
Isolate rack power before removal and follow the site machinery-protection procedure. Restore and verify rack indications and external OK-relay annunciation before releasing the system.
Alternative Names
Technical notes
Input and configuration: 3300/14-01-20-00 selects 20–34 Vdc input and standard power input module. Verify the actual input configuration and rack supply before service.
System compatibility: Review the System Monitor, backplane and monitor firmware together. A 3300/14 used with an Original backplane requires an Original Power Input Module, and it is not compatible with the 3300/01-02 System Monitor.
Approval conditions: Approval option 00 does not specify an agency approval. Assess any hazardous-area requirement at the complete installed-system level.
Technical reference: Bently Nevada 3300/14 DC Power Supply, 141497-01 Rev. J; Bently Nevada 3300 System Compatibility Guide, 104003-01 Rev. G.
FAQ View All FAQ
-
What input does 3300/14-01-20-00 require?The ordered input range is 20–34 Vdc, with maximum input current 5.5 A. This is the +26 Vdc nominal input option. Confirm the actual DC supply and polarity before energizing.
-
Which Power Input Module is selected for 3300/14-01-20-00?Standard Power Input Module is selected by option 20. Match this rear module to the installed rack backplane and field connections.
-
How many monitors can 3300/14-01-20-00 power?One power supply provides regulated power for up to 12 monitors and their associated transducers. It occupies rack position 1 at the left, beside the System Monitor.
-
Can 3300/14-01-20-00 provide different transducer supply voltages?The Power Supply PWA jumper selects -24 Vdc (+1.3%/-1.7%) or -18 Vdc (+1.6%/-2.2%). The ordered part number does not establish the current jumper position; verify the installed selection.
-
What is the purpose of the OK relay associated with 3300/14-01-20-00?The Power Input Module carries a hermetically sealed SPDT relay that is normally energized. Connect an external annunciator according to the rack wiring design so primary-power or monitoring faults are indicated.
-
What compatibility checks apply to 3300/14-01-20-00?Review the System Monitor, backplane and monitor firmware together. A 3300/14 used with an Original backplane requires an Original Power Input Module, and it is not compatible with the 3300/01-02 System Monitor.
-
What does approval option 00 mean on 3300/14-01-20-00?No agency approval required (00). Approval option 00 does not specify an agency approval. Assess any hazardous-area requirement at the complete installed-system level.
-
How is the power output protected in 3300/14-01-20-00?The supply shuts down when input voltage goes outside its permitted range and returns to normal operation when the input returns within range. Individual-channel overload protection is provided on the monitor circuit boards.
Supporting new and legacy automation
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-
We can't find any results for “”.
You May Also Like
Product Browsing History
-
Whatsapp: +86 18030235313
Send us a message. -
sales13@apterpower.com
Complete our online form. -
+86 18030235313
Speak to our team in your native language.