Match the complete marking
Match the complete Bently Nevada 31000-28-10-00-165-02-02 marking and installed configuration. Compare the assembly label, probe marking, sleeve and two conduit fittings and one plug.
-
Check the offered item before ordering
Request available label and connector photos. Have your maintenance team compare the offered 31000-28-10-00-165-02-02 with the installed equipment and applicable Bently Nevada documents.
Technical specifications for 31000-28-10-00-165-02-02
-
Manufacturer:Bently Nevada
-
Product Category:Machinery Monitoring Systems
-
Spare Part Number:31000-28-10-00-165-02-02
-
Weight:1.5 kg
-
Tariff Code:8537101190
-
Housing material:Conductive-fiber reinforced PPS
-
Sleeve material:AISI 304 stainless steel
-
Outer sleeve material:AISI 303 stainless steel
-
Housing protection:NEMA 4X / IP66
-
Mounting interface:3/4-14 NPT
-
Selected probe:3300 XL 8 mm, multiple-approval selection
-
Probe lead length:1.0 m
-
Standoff adapter:None
-
Conduit arrangement:two conduit fittings and one plug
-
Retaining-nut torque:29.4 N·m recommended
Information
- Bently Nevada 31000-28-10-00-165-02-02 keeps a radially mounted probe accessible through the machine casing. Its extended sleeve arrangement needs a stable mechanical reference and near-probe support before vibration measurements can be accepted.
Mechanical role: Environmental protection with supported probe positioning
Measurement boundary: Housing and transducer chain have different functions
The entry arrangement contains two conduit fittings and one plug, with 3/4-14 NPT mounting. Route the cable and conduit so that opening the cover or servicing the junction does not change the probe gap. The housing permits access without machine disassembly, but process and protection hazards still require controlled isolation.
The conductive-fiber reinforced PPS body and stainless-steel components provide corrosion-resistant mechanical protection. NEMA 4X/IP66 environmental protection does not establish a pressure-retaining or explosion-proof enclosure. Relative vibration measurement also requires the casing reference to be affixed to the bearing.
31000-28-10-00-165-02-02 Original Technical Excerpt
Bently Nevada 31000 and 32000 Proximity Probe Housing Assemblies, 141610 Rev. R. Selected original pages retain the relevant technical context. PDF · 5 pages.31000-28-10-00-165-02-02 Installation & Verification Guide
Apter Power installation workbook covering establish the bearing reference, brace the extended sleeve, route and seal the entries, validation and handover. PDF · 5 pages.
Application scope: These applications describe the intended system function. Select the actual configuration for that function; accessories are included only when itemized.
Radial vibration access
Position the probe from an externally serviceable housing with a bearing-referenced casing.Keyphasor mounting
Provide access to a configured radial phase-reference probe.Long-penetration installations
Support the sleeve near the probe to control mechanical resonance.Corrosive industrial environments
Use the PPS and stainless construction within its environmental and process boundaries.
Record the probe position, radial measurement direction, existing gap and receiving monitor assignment. Check that the casing provides a rigid bearing reference. Establish a controlled maintenance state before loosening any process-facing component.
Confirm the 16.5 in penetration and available adjustment. Add the required near-probe support, then check clearance throughout adjustment. Do not let support or conduit forces bend the sleeve toward the rotating target.
Install two conduit fittings and one plug using matching interfaces. Support conduit independently, protect the coaxial junction and leave cover access. Check O-ring condition and maintain a separate plan for any process leakage.
Set the working gap with the matched transducer system. Secure the retaining nut to the specified recommendation and recheck the electrical reading. Investigate any change caused by tightening or closing the cover.
Compare the restored channel with its retained configuration. Check response to controlled target movement and validate monitor indication and required alarms. Record the final assembly and electrical-chain identities.
Retain the final tested settings, physical connections and accepted operating response for 31000-28-10-00-165-02-02.
Alternative Names
Technical notes
Mechanical reference: Evaluate casing attachment and sleeve stiffness before interpreting shaft motion. Housing movement can appear in the measured signal.
Leakage boundary: The housing is not a pressure vessel. Provide safe process containment independently of its water-ingress protection.
System acceptance: After securing the sleeve, verify gap, complete transducer response and receiving monitor functions before restoring the channel.
FAQ View All FAQ
-
Why does 31000-28-10-00-165-02-02 need support near the probe rather than only at the housing?Its 16.5 in penetration exceeds the 12 in unsupported-length boundary. A near-probe support reduces sleeve resonance; verify it without changing the sensing gap.
-
Can both conduit entries on 31000-28-10-00-165-02-02 be loaded by rigid pipework?Route and support the conduits independently so their loads do not twist the housing or alter probe position.
-
How can a casing vibration contaminate the signal from 31000-28-10-00-165-02-02?Relative shaft measurement requires the casing to be fixed to the bearing reference. A moving casing adds motion to the measured gap.
-
Does an IP66 housing make 31000-28-10-00-165-02-02 a pressure vessel?No. Hose-water protection does not establish resistance to process pressure. Provide a separate leakage-containment arrangement.
-
What should be checked after the retaining nut of 31000-28-10-00-165-02-02 is tightened?Recheck the probe gap and sleeve position. Locking forces must not shift the accepted sensing point.
-
Can the electrical cable of 31000-28-10-00-165-02-02 be shortened to clear its cover?No. Route the cable without altering its calibrated length and confirm the mating extension and conditioner.
-
How does a hazardous-area installation change the assessment of 31000-28-10-00-165-02-02?Use the approved transducer system and appropriate intrinsic-safety barriers. The PPS housing itself is not explosion-proof.
-
What distinguishes a valid gap adjustment from a complete acceptance test of 31000-28-10-00-165-02-02?A gap adjustment establishes the local operating point; acceptance must also demonstrate monitor response and the required protection functions.
Supporting new and legacy automation
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-
We can't find any results for “”.
Related cases and sourcing guidance
View all case studiesYou May Also Like
Product Browsing History
-
Whatsapp: +86 18030235313
Send us a message. -
sales13@apterpower.com
Complete our online form. -
+86 18030235313
Speak to our team in your native language.