Match the complete marking
Include 1900/65A-00-01-01-00-00 and any revision or assembly number visible on the item. Keep the complete reference on the enquiry and quotation.
-
Check the offered item before ordering
Request available label and terminal photos. Have your maintenance team compare the offered 1900/65A-00-01-01-00-00 with the installed equipment and applicable Bently Nevada documentation.
Technical specifications for 1900/65A-00-01-01-00-00
-
Manufacturer:Bently Nevada
-
Product Category:Machinery Monitoring Systems
-
Spare Part Number:1900/65A-00-01-01-00-00
-
Weight:1.3 kg
-
Tariff Code:8537101190
-
Supply configuration:18-36 V DC
-
Display:Attached; no separate cable
-
Mounting / enclosure:35 mm DIN rail mounting
-
Operating current:0.35 A typical; 1.0 A maximum
-
Operating power:8.5 W typical; 14 W maximum
-
Transducer inputs:4; acceleration, velocity, radial vibration, thrust, position or speed
-
Temperature inputs:4; E/J/K/T thermocouples or 2-/3-wire RTDs
-
Relay outputs:6 SPDT; programmable logic
-
Maximum relay operands:50 per relay
-
Recorder outputs:4 x 4-20 mA; configurable channel/variable
-
Maximum recorder loop resistance:600 ohms
-
Recorder update interval:100 ms
-
Configuration retention:Non-volatile memory
-
Configuration interface:Built-in Ethernet
-
Modbus:Not included
Information
- Bently Nevada 1900/65A-00-01-01-00-00 supports local observation of machine condition in a DIN-mounted installation, bringing vibration and temperature variables onto an attached display while relay logic handles the configured protective actions.
Local access: Attached display; PC configuration through Ethernet
Protective outputs: Six programmable relays and four 4-20 mA recorders
Six SPDT relays can combine OK, Alert and Danger status through programmable expressions with up to 50 operands per relay. Latching and energized-state selections are independent. AND ignores bypassed channels while True AND includes them, which makes the exact voting expression significant during channel maintenance. Four independently assigned 4-20 mA outputs update every 100 ms and support up to 600 ohms loop resistance under the applicable loop-supply conditions.
The monitor operates from 18-36 V DC and mounts on a 35 mm DIN rail. Typical monitor demand is 0.35 A and 8.5 W, with maximum values of 1 A and 14 W. DIN mounting alone does not provide a weatherproof enclosure. The final 00 selection omits Modbus. Ethernet remains available for configuration transfer, while the four recorder outputs provide independently assigned analog variables to receiving equipment.
1900/65A-00-01-01-00-00 Official Technical Reference Excerpt
1900/65A General Purpose Equipment Monitor, 173401 Rev. AC: preserved manufacturer technical information applicable to this configuration. PDF · 9 pages.1900/65A-00-01-01-00-00 Installation & Verification Guide
Apter Power field guide covering display access, DC supply and DIN mounting, relay tests and analog recorder checks. PDF · 5 pages.
Application scope: Suitable general-purpose machines may combine vibration, temperature and discrete protection. The examples describe integration roles, not preconfigured alarm settings or a universal machine-protection design.
Local condition display
Read configured channel values at the machine-monitoring position using the attached display.Combined thermal and vibration monitoring
Pair compatible bearing-temperature circuits with the selected vibration measurements.Programmable protection contacts
Use reviewed relay expressions to combine warning, danger and channel-health states.Analog trend recording
Send selected variables to recording or control inputs using four independently assigned current loops.
Check DC polarity, supply capacity and DIN attachment before energizing the monitor.
Record transducer type, sensitivity, wiring and temperature-sensor selection.
Use the site-approved maintenance state before altering relays or alarm settings.
Match each recorder variable and full scale to the receiving input.
Test normal, alarm, Not OK, bypass and reset behavior against the approved logic.
Use Ethernet for configuration; this order code does not include Modbus process communication.
Alternative Names
Technical notes
Power boundary: 18-36 V DC. Verify supply capacity for the configured installation.
Display selection: The attached display is included without a separate display cable. Remote-display accessories are not implied.
Communication selection: The final 00 selection omits Modbus. Ethernet remains available for configuration transfer, while the four recorder outputs provide independently assigned analog variables to receiving equipment.
FAQ View All FAQ
-
How is local channel information viewed on 1900/65A-00-01-01-00-00?The BB01 selection includes an attached display, without a separate display cable. It presents channel readings and allows minor setting changes; full configuration remains a PC software task.
-
What DC capacity should be allocated to 1900/65A-00-01-01-00-00?The monitor accepts 18-36 V DC. Typical demand is 0.35 A and 8.5 W; maximum values are 1 A and 14 W. Include the rest of the cabinet load when sizing the supply.
-
Does the DIN mount on 1900/65A-00-01-01-00-00 provide environmental sealing?No. A 35 mm DIN attachment supports the monitor mechanically; it is not the weatherproof-housing selection. Provide the enclosure protection required by the installation.
-
Can the temperature channels of 1900/65A-00-01-01-00-00 use different sensor technologies?The four inputs can be configured for E, J, K or T thermocouples or two- and three-wire RTDs. Each channel must use the correct sensor selection and wiring.
-
What remains stored when 1900/65A-00-01-01-00-00 loses its DC supply?The configuration is held in non-volatile memory. Retain a controlled PC copy as well, so channel processing, setpoints, relay logic and recorder assignments can be checked after service.
-
How quickly do recorder signals update on 1900/65A-00-01-01-00-00?The four 4-20 mA recorder outputs update every 100 ms. Each represents its assigned variable and configured full scale, which must match the receiving instrument.
-
How does a maintenance bypass affect AND voting in 1900/65A-00-01-01-00-00?AND ignores bypassed channels; True AND includes them. Prove the intended relay behavior using the actual expression and approved bypass test.
-
Can the attached display replace Modbus for remote data collection on 1900/65A-00-01-01-00-00?No. Local display access does not provide a Modbus Gateway. This final-00 configuration uses relay contacts or assigned recorder loops for external process interfaces; Ethernet still supports PC configuration.
Supporting new and legacy automation
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-
We can't find any results for “”.
Related cases and sourcing guidance
View all case studies-
28 ABB BRC410 Units: Ready to Inspect, Collected on Order DayRead case > -
GE IS420UCSBH4A: Confirm the Offered Controller and Release TermsRead case > -
GE IS420UCSBH4A: Confirm the Offered Controller and Release TermsRead case > -
Siemens TP1500 Comfort: Check the Panel and Machine ProjectRead case >
You May Also Like
Product Browsing History
-
Whatsapp: +86 18030235313
Send us a message. -
sales13@apterpower.com
Complete our online form. -
+86 18030235313
Speak to our team in your native language.