Technical specifications for 177230-02-01-05
-
Manufacturer:Bently Nevada
-
Product Category:Machinery Monitoring Systems
-
Spare Part Number:177230-02-01-05
-
Weight:0.12 kg
-
Tariff Code:8537101190
-
Velocity full scale:50.8 mm/s RMS; 2.0 in/s RMS
-
Velocity frequency response:10 Hz–1 kHz, ±10%
-
Velocity output:4–20 mA, pins A–B
-
Excitation voltage:12–30 V DC; current limited to 40 mA
-
Settling time:Less than 15 s, within 2% of final value
-
Dynamic output:Unbuffered acceleration, pins C–B
-
Acceleration sensitivity:100 mV/g, ±20%
-
Acceleration full scale:15 g peak
-
Acceleration frequency response:2.5 Hz–10 kHz, ±10%
-
Dynamic output bias:2.5 V ±0.1 V relative to pin B
-
Dynamic linearity:±1% of full scale
-
Transverse sensitivity:Less than 5%
-
Mounted resonance:Greater than 12 kHz
-
Sensing element:Ceramic shear
-
Operating temperature:−40 to +85 °C; hazardous-area limits may be lower
-
Case material:316L stainless steel
-
Connector:3-pin MIL-C-5015
-
Mounting torque:4–7 N·m
-
Environmental sealing:Hermetic; to 100% RH, non-submerged
Information
- Bently Nevada 177230-02-01-05 combines a steady process-monitoring signal with access to the vibration waveform. The two outputs serve different measurements and share an electrical reference that must remain isolated from ground.
Diagnostic access: The unbuffered acceleration output allows separate waveform investigation.
Fixed measurement setup: The ordered range and response require no field adjustment or configuration.
Pins A and B carry the current loop. Pin C provides unbuffered dynamic acceleration relative to pin B, so the waveform output cannot be treated as an independent grounded instrument connection. Grounding pin B can short the current loop and remove its output; assess the reference and isolation of any connected analyzer before making the measurement.
The transmitter mounts directly to the machine through a stud and uses a ceramic shear sensing element. Mounting quality and the selected measurement location affect the transmitted vibration. Allow the output to settle after energization, then compare the loop value and a suitable independent vibration measurement under a controlled machine condition.
177230-02-01-05 Official Data Sheet Excerpt
Original English Bently Nevada transducer functions, electrical specifications and installation limits. PDF · 5 pages.177230-02-01-05 Installation & Verification Guide
Apter Power guide to the measurement path, installation checks and functional acceptance of 177230-02-01-05. PDF · 5 pages.
Application scope: Use the RMS velocity output for overall vibration trending and the dynamic acceleration output for a separately configured diagnostic measurement. Neither connection alone establishes a complete machinery protection system.
Casing-vibration trends
Trend the selected broadband RMS velocity on a correctly scaled plant analog input.Control-system vibration supervision
Use the measured velocity within an engineered monitoring function whose alarm logic and response are defined by the plant application.Waveform verification
Connect a suitable isolated measurement instrument to the dynamic output without grounding the shared return.Machine-mounted sensing
Use the stud-mounted transducer at an appropriate machine measurement location and retain a reproducible mounting condition for comparative readings.
Configure the receiving channel for the 0–50.8 mm/s range and confirm that displayed units are RMS velocity.
Check the analyzer and loop return grounding before using the dynamic output.
Use an appropriate current-limited supply within the transmitter’s excitation range.
Use the correct stud and a sound contact surface; apply 4–7 N·m mounting torque.
Do not use the initial energization transient as the steady vibration value.
For classified locations, match the actual approval marking and applicable installation drawing, entity limits and temperature restriction.
Alternative Names
Technical notes
Loop scaling: For the nominal selected range, velocity equals (current in mA minus 4) × 50.8 / 16. Apply this only within the intended normal measurement range.
RMS versus peak: The selected 01 frequency option is RMS. Do not compare its velocity value directly with a peak-valued instrument without accounting for waveform characteristics.
Analyzer connection: The dynamic signal is unbuffered and shares pin B with the loop. Verify instrument compatibility and reference isolation before connection.
FAQ View All FAQ
-
What velocity should a nominal 12 mA signal from 177230-02-01-05 represent?12 mA is halfway across the 4–20 mA span, corresponding to 25.4 mm/s RMS for this range. Check the receiving channel’s scaling and units before treating a mismatch as a sensor fault.
-
Why can connecting an analyzer to 177230-02-01-05 make its current output disappear?The dynamic signal uses pin B as its reference, and grounding that terminal can short the current loop. Check the analyzer’s input reference and isolation before reconnecting; do not assume its common is floating.
-
Can the 2.5 V bias on 177230-02-01-05 be interpreted as a vibration amplitude?No. It is the dynamic-output DC bias relative to pin B. Separate the bias from the vibration waveform using suitable instrumentation and evaluate the AC signal with the correct acceleration sensitivity.
-
Why can a peak-reading vibration instrument disagree with 177230-02-01-05 on the same machine?This configuration reports broadband RMS velocity. Peak and RMS results are different measurement quantities, and the relationship depends on the waveform. Align units, detector type and bandwidth before comparing readings.
-
How should the startup reading of 177230-02-01-05 be assessed?Allow the specified settling interval before comparing steady values: the output settles within 2% of its final value in less than 15 seconds. Check supply and machine conditions if the stabilized signal remains inconsistent.
-
Does the velocity output of 177230-02-01-05 reveal which frequency caused an increase?The loop reports overall broadband velocity and does not provide a spectrum. Use the separate dynamic acceleration output with an appropriate analyzer to investigate waveform or frequency content, keeping its reference isolated.
-
Why should a magnetic mounting base carrying 177230-02-01-05 be rolled onto the surface?Snapping it onto the machine can create a large mechanical impulse capable of damaging the electronics. Where a magnetic base is used, apply it carefully and verify a stable mounting contact before comparing vibration readings.
-
Can the general temperature rating of 177230-02-01-05 be used unchanged in a hazardous area?No. The approved hazardous-area installation may impose a lower temperature limit and specific electrical entity requirements. Check the actual marking and applicable installation drawing before selecting the supply and location.
Supporting new and legacy automation
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-
We can't find any results for “”.
Related cases and sourcing guidance
View all case studiesYou May Also Like
Product Browsing History
-
Whatsapp: +86 18030235313
Send us a message. -
sales13@apterpower.com
Complete our online form. -
+86 18030235313
Speak to our team in your native language.