Match the complete marking
Confirm 144181-51, five-metre system, 7.87 V/mm and -24 VDC on the offered nameplate.
-
Check the offered item before ordering
Check SpringLoc terminals, coaxial connector and the quoted mounting base before ordering.
Technical specifications for 144181-51
-
Manufacturer:Bently Nevada
-
Product Category:Machinery Monitoring Systems
-
Spare Part Number:144181-51
-
Weight:0.26 kg
-
Tariff Code:8537101190
-
Nameplate system length:5 m
-
Nameplate scale factor:7.87 V/mm (200 mV/mil)
-
Nominal nameplate supply:-24 VDC
-
Family nonincendive supply:-17.5 to -26 VDC, per drawing 140979
-
Family barrier supply:-23 to -26 VDC
-
Family maximum current:12 mA
-
Family output resistance:50 Ω
-
Family field-wire size:0.2-1.5 mm² (16-24 AWG)
-
Family recommended field cable:3-conductor shielded triad
-
Family maximum monitor run:305 m (1,000 ft), subject to frequency rolloff
-
Family linear range:2 mm (80 mil), complete standard XL system
-
Family nominal radial gap:-9 VDC / about 1.27 mm
-
Family 5 m ISF tolerance:±5% at 0-45°C under datasheet conditions
-
Output terminal marking:OUT
-
Common terminal marking:COM
-
Supply terminal marking:V+
Information
- The sensor is one element of a matched eddy-current measurement chain; probe, extension cable, target material and monitor configuration determine the installed result.
Connection method: SpringLoc field terminals and ClickLoc probe connector
Mounting choice: DIN rail or compatible four-hole panel arrangement
Commissioning focus: Gap voltage and complete-system response
Bently Nevada describes the 3300 XL 8 mm transducer chain as a probe, an extension cable and a Proximitor Sensor. Its output follows the clearance to a conductive target, enabling static position and dynamic vibration measurement. The manufacturer also documents backward interchangeability with 3300 5 mm and 8 mm components, but a mixed XL/non-XL chain is limited to the non-XL system performance specification.
Family performance figures are conditional on the complete standard XL system, AISI 4140 target, -24 VDC supply, 10 kΩ load and specified gap. When fitting a replacement, retain the installed five-metre electrical length, check target calibration and set the probe gap by the machine drawing and monitor procedure.
-
Original Bently Nevada datasheet excerpt
Bently Nevada 141194 Rev. AN excerpt - PDF, 3 pages. Documented product identity, system role and applicable technical details. -
Bently Nevada 144181-51 installation guide
Prepared by Apter Power - PDF, 3 pages. Identification, installation checks, commissioning and fault isolation.
Application scope: The completed transducer chain supports shaft relative vibration, axial position and other documented proximity measurements on rotating machinery.
-
Shaft vibration
Convert dynamic probe-gap changes at a fluid-film bearing into a voltage for a compatible vibration channel. -
Axial position
Observe slower changes in shaft-to-probe clearance where the machine drawing defines the target and operating gap. -
Keyphasor reference
Use a suitable probe and target feature for rotational reference or speed measurement under the manufacturer application guidance. -
Legacy 3300 exchange
A compatible 3300 5 mm or 8 mm component may physically interface, but assess the resulting mixed-system performance before acceptance.
Before removal, record OUT, COM, V+ wiring and disconnect power according to the site procedure.
Check that probe plus extension cable matches the five-metre system marking; a visual connector match is insufficient.
The family datasheet assumes AISI 4140 steel by default; another shaft material needs its own calibration basis.
Inspect ClickLoc mating surfaces, cable routing and connector protection; avoid oil ingress and mechanical strain.
Use the machine drawing and monitor procedure to establish the correct gap voltage, then record the as-left value.
After replacement, compare bias, vibration trend, alarm states and the channel configuration with the recorded baseline.
Alternative Names
Technical notes
Installation relationship: The five-metre Proximitor is installed with a compatible probe, extension cable, target and monitor input.
Performance boundary: Published 3300 XL 8 mm system performance assumes the stated complete-system test conditions; mixed XL/non-XL components use the applicable non-XL limits.
Technical reference: Bently Nevada 3300 XL 8 mm Proximity Transducer System Datasheet, 141194 Rev. AN, pp. 1-5; supplied 144181-51 nameplate.
FAQ View All FAQ
-
Why can 144181-51 show a plausible bias but inaccurate vibration amplitude?A mixed XL/non-XL chain, wrong electrical length, target material or load can change the scale factor even when a DC gap voltage appears reasonable. Check the complete chain and compare a controlled response with the installed calibration basis.
-
How should the five-metre chain for 144181-51 be identified?Record the probe order code, integral lead length and extension-cable length, then confirm their combined system length agrees with the five-metre sensor marking. Inspect the connector style and any calibrated target-material option.
-
Which supply checks matter before energizing 144181-51?Verify polarity at V+ and COM, the actual supply at the sensor under load, and whether barriers are installed. The family datasheet gives different permitted voltage ranges for the nonincendive and barrier arrangements.
-
Can 144181-51 be exchanged into a non-XL 3300 probe loop?The manufacturer documents physical and electrical interchangeability with certain non-XL 3300 5 mm and 8 mm components. The mixed loop does not inherit the full XL system performance; use the applicable non-XL specification and confirm monitor calibration.
-
What should be measured after setting the gap on 144181-51?Record the DC bias at the monitor and at the sensor if accessible, then compare the measured gap against the approved machine drawing. The family nominal -9 VDC point is a reference, not a substitute for the actual installation procedure.
-
Why does field-cable length matter for 144181-51?The family datasheet allows up to 305 m between the Proximitor and monitor with specified shielded field wiring, but longer runs attenuate high-frequency response. Check the frequency-response graph and the machine channel bandwidth.
-
How is a suspected open probe path on 144181-51 investigated?Inspect ClickLoc seating and cable damage, check the probe/extension continuity against the manufacturer procedure with power isolated, then separate sensor, cable and probe faults before changing the monitor configuration.
-
What acceptance record is useful for 144181-51 after replacement?Keep the full component markings, target material, supply and gap voltage, monitor scaling, alarm response and an as-left trend snapshot. This distinguishes a hardware change from a configuration or mechanical-clearance change.
Supporting new and legacy automation
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-
We can't find any results for “”.
Related cases and sourcing guidance
View all case studiesYou May Also Like
Product Browsing History
-
Whatsapp: +86 18030235313
Send us a message. -
sales13@apterpower.com
Complete our online form. -
+86 18030235313
Speak to our team in your native language.