Technical specifications for X67SM2436

  • Manufacturer:
    B&R
  • Product Category:
    General Automation
  • Spare Part Number:
    X67SM2436
  • Tariff Code:
    8537101190
  • Counliy of origin:
    Austria
  • Motor outputs:
    2 bipolar two-phase stepper motors
  • I/O supply:
    24 to 38.5 V DC +/-25%
  • Maximum module current:
    8 A
  • Continuous motor current:
    3 A per axis
  • Peak motor current:
    5 A per axis
  • Digital inputs:
    2 x 3; 24 V DC sink
  • Encoder use:
    Inputs configurable for incremental encoders

Information

Overview Manuals Common Applications Product Precautions
B&R X67SM2436 is two-axis x67 stepper motor module. It controls two bipolar stepper motors and acquires local digital or incremental-encoder feedback in an X67 station.
  • Drives two bipolar stepper motors
  • Supplies 3 A continuous current per axis
  • Accepts 24 V DC digital inputs
  • Supports incremental-encoder input configuration

X67SM2436 operates with X67 bus connection, two compatible stepper motors, 24-to-38.5 V DC power supply, motor cables and encoder wiring.

Engineered applications include Indexing conveyor axes, Dual stepper positioning, Distributed actuator station, Stepper-module replacement.

Important Notice: Record motor phase order, current limits, encoder assignment and axis parameters; isolate motor energy before disconnecting either axis.

Apter Power X67SM2436 Manuals and Guides

Apter Power X67SM2436 Product and System Technical Reference PDFApter Power X67SM2436 Installation and Commissioning Workbook PDF

The first document presents model-specific engineering data. The second provides a separate installation, connection, commissioning and acceptance workflow.

Indexing conveyor axes

Positions two conveyor or feeder axes.

Dual stepper positioning

Coordinates paired stepper mechanisms.

Distributed actuator station

Places motion electronics near the machine.

Stepper-module replacement

Restores motor current and encoder configuration.

Read the applicable B&R instructions before work. Verify X67SM2436 and the installed B&R X67 distributed motion I/O configuration.
1

Verify the full X67SM2436 marking and its assigned B&R X67 distributed motion I/O position before work.

2

Place the connected machine or process in the approved maintenance state.

3

Isolate the applicable supply and two stepper-motor phase outputs plus digital/encoder feedback field energy before disconnecting conductors.

4

Record connector, conductor, address and software identities before removal.

5

Use ESD controls and protect keyed interfaces, exposed contacts and electronic assemblies.

6

Confirm the installed X67 bus connection and two compatible stepper motors against the approved project.

7

Restore power in a controlled sequence and review device, network and host diagnostics.

8

Prove the intended indexing conveyor axes function and retain the final test result.

Technical notes

Record motor phase order, current limits, encoder assignment and axis parameters; isolate motor energy before disconnecting either axis.

FAQ View All FAQ

  • Which installed system position is intended for X67SM2436?
    Install X67SM2436 only in the documented B&R X67 distributed motion I/O position and verify the complete catalog marking against the approved hardware list.
  • What signal or controlled function does X67SM2436 handle?
    Its documented duty is two stepper-motor phase outputs plus digital/encoder feedback; the official record lists i/o supply as 24 to 38.5 V DC +/-25%.
  • Which companion hardware must be matched to X67SM2436?
    Match X67SM2436 with X67 bus connection and two compatible stepper motors, including the documented carrier, cable and project identity.
  • Which electrical value must be verified before wiring X67SM2436?
    Verify continuous motor current: 3 A per axis. Do not transfer limits from another catalog number.
  • How should the configuration be preserved when replacing X67SM2436?
    Record the as-found position, conductors, addressing and software revision, then restore only the approved B&R X67 distributed motion I/O configuration.
  • Which isolation and handling checks apply to X67SM2436?
    Isolate the documented supply and field energy, use ESD controls and protect the keyed connectors before handling X67SM2436.
  • How should an engineer commission X67SM2436?
    Power up in a controlled sequence, review device and host diagnostics, then prove the intended indexing conveyor axes function.
  • Can X67SM2436 replace a visually similar module without further checks?
    No automatic substitution is assumed; compare the full catalog number, interfaces, motor outputs and approved system revision.
Related reading

Related cases and sourcing guidance

View all case studies
Manufacturers

Product Browsing History

Revisit the products you recently viewed on Apter Power.
SPEAK TO OUR TEAM
Let’s find the right solution for you.
Send us the part number, quantity and delivery destination. Our team will help confirm availability and lead time.
  • Whatsapp: +86 18030235313

    Send us a message.
  • sales13@apterpower.com

    Complete our online form.
  • +86 18030235313

    Speak to our team in your native language.