Speak to a sourcing specialist
sales13@apterpower.com
Get a quick price for 7EX290.50-1
E-mail *
Mobile *
Company
Content *
Quantity *
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy

What happens after you enquire

  • 1

    Requirement review

    We review the part number, quantity and delivery requirements and ask for any missing details.
  • 2

    Quotation and availability

    We confirm the proposed item, condition, availability, price and estimated lead time in the quotation.
  • 3

    Order confirmation and dispatch

    Once the quotation and purchasing details are agreed, your contact will coordinate the order and available dispatch information.

Technical specifications for 7EX290.50-1

  • Manufacturer:
    B&R
  • Product Category:
    PLC Systems
  • Spare Part Number:
    7EX290.50-1
  • Tariff Code:
    8537101190
  • Counliy of origin:
    Austria
  • Function:
    X2X Link bus controller
  • Supply:
    24 V DC
  • Power consumption:
    3.2 W
  • X2X interfaces:
    1
  • Isolation:
    X2X Link electrically isolated
  • Terminal block:
    Ordered separately

Information

Overview Manuals Common Applications Product Precautions
B&R 7EX290.50-1 is system 2003 x2x link bus controller. It connects System 2003 I/O to an electrically isolated X2X Link network.
  • Provides one X2X Link interface
  • Uses a 24 V DC supply
  • Electrically isolates the expansion link
  • Connects a System 2003 station to X2X

7EX290.50-1 operates with System 2003 rack, separate terminal block, X2X Link cable, upstream B&R controller.

Engineered applications include System 2003 remote I/O, X2X migration interface, Electrically isolated expansion link, Bus-controller replacement.

Important Notice: Record X2X node and rack identities, match the separately ordered terminal block and verify all remote I/O after controlled startup.

Apter Power 7EX290.50-1 Manuals and Guides

Apter Power 7EX290.50-1 Product and System Technical Reference PDFApter Power 7EX290.50-1 Installation and Commissioning Workbook PDF

The first document presents model-specific engineering data. The second provides a separate installation, connection, commissioning and acceptance workflow.

System 2003 remote I/O

Extends legacy System 2003 I/O over X2X.

X2X migration interface

Interfaces old and current B&R architectures.

Electrically isolated expansion link

Separates remote-station communication electrically.

Bus-controller replacement

Restores the expansion node without changing rack addressing.

Read the applicable B&R instructions before work. Verify 7EX290.50-1 and the installed B&R System 2003 expansion configuration.
1

Verify the full 7EX290.50-1 marking and its assigned B&R System 2003 expansion position before work.

2

Place the connected machine or process in the approved maintenance state.

3

Isolate the applicable supply and electrically isolated x2x link process data field energy before disconnecting conductors.

4

Record connector, conductor, address and software identities before removal.

5

Use ESD controls and protect keyed interfaces, exposed contacts and electronic assemblies.

6

Confirm the installed System 2003 rack and separate terminal block against the approved project.

7

Restore power in a controlled sequence and review device, network and host diagnostics.

8

Prove the intended system 2003 remote i/o function and retain the final test result.

Technical notes

Record X2X node and rack identities, match the separately ordered terminal block and verify all remote I/O after controlled startup.

FAQ View All FAQ

  • Which installed system position is intended for 7EX290.50-1?
    Install 7EX290.50-1 only in the documented B&R System 2003 expansion position and verify the complete catalog marking against the approved hardware list.
  • What signal or controlled function does 7EX290.50-1 handle?
    Its documented duty is electrically isolated x2x link process data; the official record lists supply as 24 V DC.
  • Which companion hardware must be matched to 7EX290.50-1?
    Match 7EX290.50-1 with System 2003 rack and separate terminal block, including the documented carrier, cable and project identity.
  • Which electrical value must be verified before wiring 7EX290.50-1?
    Verify x2x interfaces: 1. Do not transfer limits from another catalog number.
  • How should the configuration be preserved when replacing 7EX290.50-1?
    Record the as-found position, conductors, addressing and software revision, then restore only the approved B&R System 2003 expansion configuration.
  • Which isolation and handling checks apply to 7EX290.50-1?
    Isolate the documented supply and field energy, use ESD controls and protect the keyed connectors before handling 7EX290.50-1.
  • How should an engineer commission 7EX290.50-1?
    Power up in a controlled sequence, review device and host diagnostics, then prove the intended system 2003 remote i/o function.
  • Can 7EX290.50-1 replace a visually similar module without further checks?
    No automatic substitution is assumed; compare the full catalog number, interfaces, function and approved system revision.
Manufacturers

Product Browsing History

Revisit the products you recently viewed on Apter Power.
SPEAK TO OUR TEAM
Let’s find the right solution for you.
Send us the part number, quantity and delivery destination. Our team will help confirm availability and lead time.
  • Whatsapp: +86 18030235313

    Send us a message.
  • sales13@apterpower.com

    Complete our online form.
  • +86 18030235313

    Speak to our team in your native language.