Technical specifications for TA25DU-1.8M 1SAZ211201R2025
-
Manufacturer:ABB
-
Product Category:General Automation
-
Spare Part Number:1SAZ211201R2025
-
Weight:0.15 kg
-
Current setting range:1.30–1.80 A
-
Trip class:10A
-
Main poles:3
-
Operational voltage:690 V AC
-
Auxiliary contacts:1 NO + 1 NC
-
Reset selection:Manual or automatic
-
Short-circuit fuse reference:6 A gG or 4 A aM
-
Impulse withstand:6 kV
-
Compensated ambient:-25 to +55°C
-
Main-terminal torque:1.4–2.0 N·m
-
Auxiliary-terminal torque:0.8–1.3 N·m
-
Main conductor range:0.75–4 mm² for this current group
Information
- ABB TA25DU-1.8M 1SAZ211201R2025 protects a compatible motor starter against sustained overload and phase failure through thermally operated bimetal elements.
Overload behavior: Trip class 10A
Auxiliary circuits: Separate 1 NO and 1 NC contacts
The 95–96 NC contact and 97–98 NO contact are electrically separate. Their functions in the contactor control and trip indication circuit must be checked independently, including the selected manual or automatic reset behavior.
The relay is phase-loss sensitive and temperature compensated within its specified ambient range. It requires coordination with the starter and short-circuit protective device; the thermal trip function does not replace short-circuit protection.
TA25DU-1.8M 1SAZ211201R2025 Official Technical Excerpt
The original technical excerpt applicable to ABB TA25DU-1.8M 1SAZ211201R2025 covers exact current range, utilization ratings and terminal data. PDF · 3 pages.TA25DU-1.8M 1SAZ211201R2025 Installation & Verification Guide
Apter Power installation and verification guide covering motor setting, contactor fit, terminal torque, trip and reset tests. PDF · 5 pages.
Application scope: Apply the exact 1.30–1.80 A range to the motor duty and preserve the coordinated starter circuit.
Small motor overload
Set thermal protection within the selected current adjustment range.Phase-failure protection
Use the phase-loss-sensitive mechanism in the compatible starter.Trip indication
Wire the NO auxiliary contact to the intended indication circuit.Contactor interruption
Use the NC contact in the approved control path to stop the motor.
Match the setting to the motor and duty.
Retain the coordinated upstream protective device.
Assess automatic restart risk before choosing automatic reset.
Keep 95–96 and 97–98 functions distinct.
Apply the separate main and auxiliary torque values.
Verify the contactor and indication response to a trip.
Alternative Names
Technical notes
Signal and interface: The main circuit has a 690 V AC operational rating. Auxiliary contact utilization ratings are separate and depend on voltage and switching category.
Installation boundary: Use the correct terminal torque: 1.4–2.0 N·m for the main circuit and 0.8–1.3 N·m for auxiliary terminals.
Technical basis: ABB Motor Protection and Control Catalogue, 1SBC100179C0201; TA25DU-M technical data 2CDC106056C0201. The 1.30–1.80 A row is TA25DU-1.8M, order code 1SAZ211201R2025. General TA25DU-M ratings apply subject to the stated utilization and mounting conditions.
FAQ View All FAQ
-
What current range can TA25DU-1.8M 1SAZ211201R2025 be set to?The adjustment range is 1.30–1.80 A.
-
Does TA25DU-1.8M 1SAZ211201R2025 provide short-circuit protection by itself?No. Coordinate it with the appropriate short-circuit protective device; its main purpose is overload and phase-failure protection.
-
Which auxiliary contact on TA25DU-1.8M 1SAZ211201R2025 is normally closed?Terminals 95–96 are NC; terminals 97–98 provide the separate NO contact.
-
Can TA25DU-1.8M 1SAZ211201R2025 reset automatically?Manual or automatic reset can be selected. Assess the motor restart behavior before enabling automatic reset.
-
What trip class applies to TA25DU-1.8M 1SAZ211201R2025?The thermal overload mechanism is trip class 10A.
-
Which torque is used on the main terminals of TA25DU-1.8M 1SAZ211201R2025?For this current group, the main terminal torque is 1.4–2.0 N·m; auxiliary terminals use 0.8–1.3 N·m.
-
What fuse references accompany the current range of TA25DU-1.8M 1SAZ211201R2025?The selection table gives 6 A gG or 4 A aM; confirm the complete starter coordination for the installation.
-
How should the trip function of TA25DU-1.8M 1SAZ211201R2025 be accepted?Exercise the test function, verify the NC control path stops the contactor, check NO trip indication and confirm the intended reset behavior.
Supporting new and legacy automation
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-
We can't find any results for “”.
Related cases and sourcing guidance
View all case studiesYou May Also Like
Product Browsing History
-
Whatsapp: +86 18030235313
Send us a message. -
sales13@apterpower.com
Complete our online form. -
+86 18030235313
Speak to our team in your native language.