Match the complete marking
Send the complete CI547 3BNP004429R1 marking, all revision labels, current-unit photographs and installed position.
-
Check the offered item before ordering
Compare the offered CI547 3BNP004429R1 interfaces, revision and included items with the approved system record before ordering.
Technical specifications for CI547 3BNP004429R1
-
Manufacturer:ABB
-
Product Category:DCS Systems
-
Spare Part Number:CI547 3BNP004429R1
-
Weight:0.16 kg
-
Tariff Code:8537101190
-
Product type:MasterBus 300 Communication Board with Slave Processor
-
System platform:Advant Master AC 450 / AC 460 and MasterBus 300
-
Type designation:CI547
-
ABB product ID:3BNP004429R1
-
Protocol family:MasterBus 300 / MasterBus 300E
-
Board role:Communication interface
-
Processor arrangement:Includes slave processor
-
Host benefit:Reduces load on central processor module PM150
-
Installed controller use:AC 450 / AC 460 installed base
-
Module class:Communication module
-
Replacement basis:Product ID, board revision and MB300 execution
-
Network boundary:Bus media, node configuration and controller database
-
Lifecycle context:While-supplies-last installed-base part
-
Replacement basis:Complete marking and installed-system evidence
Information
- ABB CI547 3BNP004429R1 is a masterbus 300 communication board with slave processor documented for Advant Master AC 450 / AC 460 and MasterBus 300.
MB300 and MB300E interface role: Bus execution and installed network hardware must agree with the offered board.
Controller-load coordination: Communication recovery is verified together with PM150 load, node status and controller diagnostics.
The slave processor reduces the communication load on the central PM150 processor. Network media, controller software, addressing and bus execution remain installation-dependent.
Before exchange, capture node and database records, bus connections and board revision. After installation, verify controller recognition, stable bus status and expected peer communication.
CI547 3BNP004429R1 Technical Reference
ABB Advant Master AC 450 installed-base parts documentation. Verified identifiers, ratings and evidence boundaries applicable to CI547 3BNP004429R1.CI547 3BNP004429R1 Installation & Verification Guide
Product-specific field guide for identity capture, controlled exchange, commissioning evidence and handover.
Application scope: Use CI547 3BNP004429R1 only where the product identity, revision, configuration and approved system documentation agree.
MasterBus 300 communication
Connect installed Advant Master controllers and stations on the approved bus.AC450/AC460 maintenance
Restore the documented communication-board and central-processor relationship.Network fault isolation
Separate cable, node, board and controller-database causes.Installed-base spare planning
Match CI547, 3BNP004429R1, revision and bus execution.
Confirm MB300 or MB300E media and network design.
Capture PM150 relationship, rack slot and board revision.
Retain addresses, peers and controller database.
Check media, shields, connectors and termination.
Verify board recognition before enabling peer traffic.
Confirm stable bus status and required controller peers.
Alternative Names
Technical notes
Exact identity: CI547 3BNP004429R1
Documented function: MasterBus 300 Communication Board with Slave Processor
Technical evidence: ABB Advant Master AC 450 installed-base parts documentation
Verification boundary: Confirm the complete marking and installed Advant Master AC 450 / AC 460 and MasterBus 300 arrangement before selection
FAQ View All FAQ
-
How should the MasterBus execution be confirmed for CI547 3BNP004429R1?Identify whether the installed network uses MasterBus 300 or MB300E and match the board revision, media and controller configuration.
-
What role does the slave processor in CI547 3BNP004429R1 play during replacement planning?Preserve the board execution that handles communication work separately from PM150, and verify the host controller recognizes that arrangement.
-
Which PM150 relationship should be recorded before removing CI547 3BNP004429R1?Capture the host processor revision, rack position, communication load and database relationship before disturbing the board.
-
How should node identity be restored for CI547 3BNP004429R1?Retain the approved network address and controller database, then compare the active peer list after startup.
-
What bus-media checks apply when installing CI547 3BNP004429R1?Inspect the installed MB300 media, connectors, shielding and termination against the approved network drawing.
-
How should revision compatibility be assessed for CI547 3BNP004429R1?Compare the complete 3BNP004429R1 identity, hardware revision, firmware and AC450/AC460 execution before approval.
-
How can a network problem involving CI547 3BNP004429R1 be isolated?Separate carrier power, board diagnostics, bus media, node configuration and controller-database causes before replacing peer devices.
-
What is the acceptance test for CI547 3BNP004429R1?Require controller recognition, stable bus status, expected peer communication and no new PM150 or communication diagnostics.
Supporting new and legacy automation
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-
We can't find any results for “”.
Related cases and sourcing guidance
View all case studiesYou May Also Like
Product Browsing History
-
Whatsapp: +86 18030235313
Send us a message. -
sales13@apterpower.com
Complete our online form. -
+86 18030235313
Speak to our team in your native language.