PSTX300-600-70-1SFA898114R7000

Motor Softstarter
Ships by Saturday, November 7
ABB PSTX300-600-70-1SFA898114R7000 (1)
ABB PSTX300-600-70-1SFA898114R7000 (2)
ABB PSTX300-600-70-1SFA898114R7000 (3)
ABB PSTX300-600-70-1SFA898114R7000 (1)
ABB PSTX300-600-70-1SFA898114R7000 (2)
ABB PSTX300-600-70-1SFA898114R7000 (3)
Product image is representative; revision or series may vary. Contact us to request a specific version.

Product Describe:

ABB PSTX300-600-70-1SFA898114R7000 is a 300 A three-phase softstarter for 208-600 V AC motors, with built-in bypass and 100-250 V AC control supply.
  • Manufacturer part number
    PSTX300-600-70-1SFA898114R7000
  • Shipping
    Swift global dispatch
  • Condition
    New, original product
  • Shipping size (est.)
    25.6cm x 28cm x 47cm
  • Country of Origin
    Sweden
Get a quick price for PSTX300-600-70-1SFA898114R7000
E-mail *
Mobile *
Company
Content *
Quantity *
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy

What happens after you enquire

  • 0

    Review your reference

    Send the complete PSTX300-600-70-1SFA898114R7000 marking, quantity and installed configuration for review.

  • 1

    Confirm the offer

    Check the quoted condition, included items and dispatch date for the specified PSTX300-600-70-1SFA898114R7000.

  • 2

    Arrange dispatch

    Confirm delivery details and receive the tracking reference when the agreed shipment is arranged.

  • Match the complete marking

    Compare PSTX300-600-70-1SFA898114R7000 with the complete installed nameplate and product ID.

  • Check the offered item before ordering

    Confirm PSTX300-600-70 and 1SFA898114R7000, the control-supply marking, display and terminal/accessory scope. Protective and communication accessories are separate unless quoted.

Technical specifications for PSTX300-600-70-1SFA898114R7000

  • Manufacturer:
    ABB
  • Product Category:
    General Automation
  • Spare Part Number:
    PSTX300-600-70-1SFA898114R7000
  • Weight:
    15.35 kg
  • Tariff Code:
    8537101190
  • Type designation:
    PSTX300-600-70
  • Product ID:
    1SFA898114R7000
  • Product family:
    PSTX softstarters
  • Rated operational current, IEC in-line:
    300 A
  • Operational voltage:
    208-600 V AC
  • Control supply voltage:
    100-250 V AC
  • Control supply frequency:
    50/60 Hz
  • Control arrangement:
    Three-phase controlled soft start and stop
  • Starting/stopping modes:
    Voltage ramp or torque ramp
  • Bypass:
    Built-in
  • IEC motor power at 380-400 V, in-line:
    160 kW
  • IEC motor power at 500 V, in-line:
    200 kW
  • IEC rated-current setting range:
    90-300 A
  • IEC inside-delta rated motor current:
    515 A under the specified arrangement
  • Integrated motor protection:
    Electronic overload protection
  • Overload trip classes:
    10A, 10, 20 and 30
  • Relay status outputs:
    RUN, TOR and Event
  • Operator interface:
    Detachable graphical display
  • Application functions:
    Current limit, kickstart, motor heating and pump cleaning

Information

Overview Downloads Applications / Compatibility Product Precautions
  • ABB PSTX300-600-70-1SFA898114R7000 controls the motor starting and stopping ramp before its internal bypass carries running current. Select the circuit from motor current, starting duty and installation conditions.
Product type: Three-phase motor softstarter
IEC in-line current: 300 A
Supply selection: 208-600 V AC main / 100-250 V AC control
ABB PSTX300-600-70-1SFA898114R7000 is selected for a 208-600 V AC main circuit and a separate 100-250 V AC, 50/60 Hz control supply. Its IEC normal-start rating is 300 A for an in-line connection; the corresponding inside-delta selection is 515 A. These connection-specific figures must be applied with the appropriate motor wiring and starting duty, rather than treated as interchangeable current settings.

PSTX supports voltage-ramp and torque-controlled starting and stopping. Torque control shapes the motor response during acceleration or deceleration, while current and overload settings must match the motor and load. Starting time, starting frequency and normal- or heavy-duty selection affect the suitable softstarter size and protection configuration.

The internal bypass engages at full speed to reduce operating losses and heat generation. The platform also provides electronic motor-overload protection, a graphical operator interface and built-in Modbus RTU for monitoring and control. The bypass function does not provide electrical isolation; short-circuit protection and coordination remain part of the complete motor-starter circuit.
Controller platform reference: PSTX motor starting platform. Select by motor current and starting duty.
Technical downloads for ABB PSTX300-600-70-1SFA898114R7000: original manufacturer reference pages and an Apter Power installation and commissioning guide.
The technical reference preserves selected manufacturer pages. The installation guide is compiled by Apter Power for preparation and review; apply the original operating procedures and site controls during work.
Prepare ABB PSTX300-600-70-1SFA898114R7000 using the installed-system design, controlled isolation and the applicable manufacturer procedure.
Match both supply circuits

Use the 208-600 V AC main-voltage version with its 100-250 V AC control supply. Keep line and control terminals clearly identified.

Select the connection arrangement

Use the correct in-line or inside-delta wiring diagram. Set motor current according to that arrangement and the motor nameplate.

Assess the starting duty

Check acceleration, starts per hour, ambient conditions and load inertia. A 300 A rating alone does not establish a suitable heavy-duty selection.

Coordinate protective devices

Select the required short-circuit protection and isolation devices. The internal bypass and electronic overload protection serve different functions.

Control unexpected motion

Isolate main and control power before wiring or service. Account for remote commands and automatic sequences before releasing the motor.

Verify ramps and trips

Set and test the chosen ramp, current limit and overload class with controlled motor operation before returning the process to service.

Alternative Names

1SFA898114R7000

Technical notes

Connection relationship: The 300 A IEC in-line and 515 A inside-delta figures describe different circuit arrangements. Match the wiring diagram and motor-current setting before energizing.

Protection boundary: Built-in bypass and electronic overload protection do not replace maintenance isolation or coordinated short-circuit protection.

Technical reference: ABB PSTX Softstarters catalog, 1SFC132011C0201; PSTX Installation and commissioning manual, 1SFC132081M0201 Rev. O.

FAQ View All FAQ

  • What are the separate main and control voltage ranges of PSTX300-600-70-1SFA898114R7000?
    The 600-version main circuit is rated for 208-600 V AC. The -70 control supply is 100-250 V AC at 50/60 Hz; it is a separate circuit and must be connected to the designated terminals.
  • Is PSTX300-600-70-1SFA898114R7000 rated for a 690 V main supply?
    No. This exact -600 model is the 208-600 V AC version. A rating table for a -690 variant must not be transferred to product 1SFA898114R7000.
  • How does the built-in bypass operate in PSTX300-600-70-1SFA898114R7000?
    PSTX uses controlled semiconductor starting and stopping, with an internal bypass for running operation. The bypass reduces running losses but is not a maintenance isolator.
  • Which motor-current figures apply to in-line and inside-delta use of PSTX300-600-70-1SFA898114R7000?
    The IEC ratings table gives 300 A for the in-line arrangement and 515 A for the specified inside-delta arrangement. Select wiring and current settings for the actual circuit rather than using the higher figure on an in-line installation.
  • What IEC motor power is associated with PSTX300-600-70-1SFA898114R7000 at 400 V?
    The specified normal-start IEC in-line selection is 160 kW at 380-400 V. Verify motor current, starting duty and application conditions before relying on the nominal power selection.
  • Which overload tripping classes can be selected on PSTX300-600-70-1SFA898114R7000?
    The integrated electronic overload protection supports classes 10A, 10, 20 and 30. Choose the class from the motor and starting duty, then verify the protection settings during commissioning.
  • Can PSTX300-600-70-1SFA898114R7000 control stopping through a torque ramp?
    The PSTX platform provides voltage-ramp or torque-ramp soft start and stop. Select the appropriate function and confirm the real load response, especially for a pump application.
  • Which relay states can be integrated from PSTX300-600-70-1SFA898114R7000?
    The available relay signals include RUN, TOR and Event. Wire and configure these outputs to the plant control design and check their observed states during the start, running and fault sequences.
Related reading

Related cases and sourcing guidance

View all case studies
Manufacturers

Product Browsing History

Revisit the products you recently viewed on Apter Power.
SPEAK TO OUR TEAM
Let’s find the right solution for you.
Send us the part number, quantity and delivery destination. Our team will help confirm availability and lead time.
  • Whatsapp: +86 18030235313

    Send us a message.
  • sales13@apterpower.com

    Complete our online form.
  • +86 18030235313

    Speak to our team in your native language.