Match the complete marking
Include the complete ABB 1SDA083360R1 marking and any hardware revision on the item. Check the Protect version, sensor types, rating plug and trip circuit.
-
Check the offered item before ordering
Request available label and connector photos. Have your maintenance team compare the offered 1SDA083360R1 with the installed equipment and applicable ABB documents.
Technical specifications for 1SDA083360R1
-
Manufacturer:ABB
-
Product Category:General Automation
-
Spare Part Number:1SDA083360R1
-
Weight:1.15 kg
-
Tariff Code:8537101190
-
Protection version:Ekip UP Protect
-
System voltage:Up to 1150 V
-
Current application range:100–6300 A with the selected sensors and rating plug
-
System frequency:50–60 Hz
-
Operating temperature:-25 to +70°C; maximum +60°C for UL
-
Protection degree:IP40; IP54 with suitable external cover
-
System current precision:1% under Type C sensor reference conditions
-
System voltage precision:0.7% under stated reference conditions
-
System power precision:2% under stated reference conditions
-
Harmonic analysis:Up to 50th harmonic
-
Data-logger sampling:1200, 2400, 4800 or 9600 Hz
-
Maximum recording duration:16 seconds
Information
- ABB 1SDA083360R1 adds electronic protection and measurement to an existing switching arrangement while retaining the separately engineered trip and sensing circuits.
Measured quantities: Current, voltage, frequency and power
Integration: Separate sensing and switching circuits
The installation uses the selected current sensors, rating plug and voltage inputs to establish its measurement range. Metering precision with sensors differs from unit-only precision, so the complete sensing chain and transformer accuracy must be considered.
A trip path connects the protection decision to the switching device. Commissioning must verify actual opening behavior and diagnostics, including sensor, rating-plug and trip-coil continuity, rather than ending with a correct display reading.
1SDA083360R1 Official Technical Excerpt
The original technical excerpt applicable to ABB 1SDA083360R1 covers Protect-version scope, system ratings, metering and ordering identity. PDF · 5 pages.1SDA083360R1 Installation & Verification Guide
Apter Power installation and verification guide covering sensor selection, protection settings, trip interface and functional injection tests. PDF · 5 pages.
Application scope: Use only functions enabled for the Protect version and the actual fitted accessories and software.
Feeder protection
Apply current, voltage, frequency and power protection to the designed feeder.Switchgear modernization
Add electronic functions to an existing switching arrangement.Power-quality review
Inspect harmonic and voltage-event measurements under the configured limits.Fault investigation
Use event and waveform records to evaluate protection operation.
Do not assign Protect+ or Control+ functions to this article.
Match current sensors and the rating plug to the circuit.
Apply the correct voltage-transformer ratio and accuracy.
Prove the actual switching-device opening path.
Retain approved protection thresholds and delays.
Test metering, diagnostics and trip behavior together.
Alternative Names
Technical notes
Signal and interface: The 100–6300 A range is a system application range requiring the selected sensors and rating plug; it is not a direct-current rating for the unit terminals.
Installation boundary: Type C reference conditions govern the stated system precision. Voltage transformers, when used for those values, require class 0.2 or better.
Technical basis: ABB Ekip UP Technical Catalogue, 1SDC001051D0201, May 2020. Article 1SDA083360R1 is Ekip UP Protect, not Protect+ or Control+. Sensor-dependent metering values require the stated Type C installation conditions.
FAQ View All FAQ
-
Is 1SDA083360R1 the Ekip UP Protect+ version?No. Article 1SDA083360R1 identifies Ekip UP Protect.
-
Which electrical quantities support protection on 1SDA083360R1?The Protect version uses current, voltage, frequency and power protection functions.
-
Can the 6300 A application limit of 1SDA083360R1 be connected directly to its terminals?No. The application range depends on the selected current sensors and rating plug; it is not a direct terminal current rating.
-
Why are sensor-system precision values different for 1SDA083360R1?Sensor and installation errors add to unit measurement error. Under Type C reference conditions, system current precision is 1% rather than the unit-only 0.5%.
-
What voltage-transformer condition accompanies the precision figures for 1SDA083360R1?Where a VT is used for the stated reference values, its accuracy class must be 0.2 or better and the installation conditions must be satisfied.
-
How far does harmonic analysis extend on 1SDA083360R1?The network-analysis function covers harmonics up to the 50th order.
-
Which sampling choices are available for the data logger in 1SDA083360R1?The sampling choices are 1200, 2400, 4800 and 9600 Hz, with a maximum recording duration of 16 seconds.
-
Why must the trip path be tested separately on 1SDA083360R1?Correct measurements do not prove that the switching device opens. Test the trip interface, continuity diagnostics and actual protection action.
Supporting new and legacy automation
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-
We can't find any results for “”.
Related cases and sourcing guidance
View all case studiesYou May Also Like
Product Browsing History
-
Whatsapp: +86 18030235313
Send us a message. -
sales13@apterpower.com
Complete our online form. -
+86 18030235313
Speak to our team in your native language.