Speak to a sourcing specialist
sales13@apterpower.com

BCU-12 3AUA0000110430

Drive Control Unit
Ships by Friday, November 6
ABB BCU-12 3AUA0000110430 (1)
ABB BCU-12 3AUA0000110430 (2)
ABB BCU-12 3AUA0000110430 (3)
ABB BCU-12 3AUA0000110430 (1)
ABB BCU-12 3AUA0000110430 (2)
ABB BCU-12 3AUA0000110430 (3)
Product image is representative; revision or series may vary. Contact us to request a specific version.

Product Describe:

ABB BCU-12 3AUA0000110430 is a converter control unit with seven fiber-optic connections and integrated converter-data logging.
  • Manufacturer part number
    BCU-12 3AUA0000110430
  • Shipping
    Swift global dispatch
  • Condition
    New, original product
  • Shipping size (est.)
    31cm x 14cm x 8.3cm
  • Country of Origin
    Sweden
Get a quick price for BCU-12 3AUA0000110430
E-mail *
Mobile *
Company
Content *
Quantity *
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy

What happens after you enquire

  • 0

    Review your reference

    Send the full BCU-12 3AUA0000110430 marking and installed ABB BCU control units configuration.
  • 1

    Confirm the offer

    Review the exact assembly, condition, included items and quoted dispatch date.
  • 2

    Arrange dispatch

    Confirm delivery details for BCU-12 3AUA0000110430; tracking follows when shipment is arranged.
  • Match the complete marking

    Include BCU-12 3AUA0000110430 and any revision or assembly number visible on the item. Keep the exact reference on your enquiry and quotation.

  • Check the offered item before ordering

    Request available label and connector photos. Have your maintenance team compare the offered BCU-12 3AUA0000110430 with the installed equipment and applicable ABB documentation.

Technical specifications for BCU-12 3AUA0000110430

  • Manufacturer:
    ABB
  • Product Category:
    General Automation
  • Spare Part Number:
    BCU-12 3AUA0000110430
  • Weight:
    1.55 kg
  • Tariff Code:
    8537101190
  • Function:
    Converter control via fiber-optic links
  • Optical channels:
    7, V1–V7
  • External supply:
    24 V DC ±10%, 2 A
  • Redundant supply inputs:
    Two connections at XPOW
  • Digital inputs:
    6, DI1–DI6
  • Configurable digital I/O:
    2, DIO1 and DIO2
  • Analog inputs:
    2 differential; −10…+10 V or −20…+20 mA
  • Analog outputs:
    2; 0–20 mA, load <500 ohms
  • Relay outputs:
    3; 250 V AC / 30 V DC, 2 A
  • Drive-to-drive interface:
    RS-485 at XD2D
  • Diagnostic memory:
    SDHC; maximum 8 GB
  • Control-panel interface:
    RJ-45 at X13, cable <3 m

Information

Overview Downloads Applications / Compatibility Product Precautions
  • ABB BCU-12 3AUA0000110430 links converter modules to the drive control program. Its optical branches and removable memory support coordinated converter control and fault analysis.
Product type: Converter control unit
Optical connections: Seven, V1–V7
Power input: 24 V DC ±10%, 2 A at XPOW
BCU-12 provides seven fiber-optic converter connections. Its BPEB-05 expansion board adds five branches to the two basic connections, while integrated branching functionality collects converter data on an SDHC card for service analysis. Optical pairs connected to the same control unit must have equal lengths; the supported cable limit depends on fiber construction.

The control interfaces include six digital inputs, two configurable digital inputs/outputs, two differential analog inputs, two analog outputs and three relay outputs. Analog inputs support −10 to +10 V or −20 to +20 mA selection; analog outputs provide 0–20 mA into a load below 500 ohms. XPOW accepts two external 24 V DC supplies for redundancy.

Three option slots accept applicable F-type adapters or I/O extensions, with an additional RDCO communication option position. The converter memory unit is separate from the SDHC diagnostic card and must not be exchanged while powered. Units using BCON-12 revision R or later require a firmware and bootloader compatibility review; the physical BCU-12 identity alone does not establish compatibility with an older drive.
Controller platform reference: ABB BCU control units. Match the installed configuration.
Technical downloads for BCU-12 3AUA0000110430: an original ABB reference excerpt and an Apter Power installation planning guide.
Hardware values describe BCU-12. From internal BCON-12 revision R, compatibility with older firmware and bootloaders is restricted; confirm the actual hardware and software combination before replacement. The planning guide is prepared by Apter Power; apply the complete manufacturer instructions and the stated applicability boundaries.
System and supply context: Hardware values describe BCU-12. From internal BCON-12 revision R, compatibility with older firmware and bootloaders is restricted; confirm the actual hardware and software combination before replacement. Accessories are included only when itemized in the quotation.

Platform applications: The following applications describe ABB BCU control units functions. Match the complete BCU-12 3AUA0000110430 identity to the installed system before selecting a replacement.
Prepare BCU-12 3AUA0000110430 against the installed configuration and applicable ABB instructions. Plan isolation and the resulting interruption of system operation before replacement.
Isolate the drive

Follow the drive safety instructions and verify discharge before accessing the control unit.

Check hardware revision

Review the BCON-12 revision and firmware compatibility, especially revision R and later.

Match optical pairs

Retain optical channel assignments and equal cable-pair lengths.

Select analog mode

Match current or voltage input selection to the connected signal source.

Protect stored data

Do not remove the SDHC card while WRITE is lit; do not exchange converter memory while powered.

Validate configuration

Confirm the correct control program, converter hardware and safety interfaces before releasing the drive.

Alternative Names

BCU-12 3AUA0000110430 ABB BCU-12 3AUA0000110430

Technical notes

Installation relationship: The control interfaces include six digital inputs, two configurable digital inputs/outputs, two differential analog inputs, two analog outputs and three relay outputs. Analog inputs support −10 to +10 V or −20 to +20 mA selection; analog outputs provide 0–20 mA into a load below 500 ohms. XPOW accepts two external 24 V DC supplies for redundancy.

Configuration: Hardware values describe BCU-12. From internal BCON-12 revision R, compatibility with older firmware and bootloaders is restricted; confirm the actual hardware and software combination before replacement.

Technical reference: ABB BCU-02/12/22 Control Units Hardware Manual, 3AUA0000113605 Rev. D; ABB 3AUA0000110430 product information.

FAQ View All FAQ

  • How many converter links does BCU-12 3AUA0000110430 provide?
    BCU-12 provides seven fiber-optic connections, V1–V7, using one BPEB-05 expansion board.
  • What external supply does BCU-12 3AUA0000110430 require?
    XPOW is rated for 24 V DC ±10%, 2 A. Two supplies can be connected for redundancy.
  • Which analog signals can BCU-12 3AUA0000110430 accept?
    The two differential analog inputs support −10 to +10 V or −20 to +20 mA. Select the input mode with the corresponding switches.
  • What load applies to the analog outputs on BCU-12 3AUA0000110430?
    The two analog outputs provide 0–20 mA and require a load resistance below 500 ohms.
  • What is stored on the diagnostic card of BCU-12 3AUA0000110430?
    The SDHC card records converter-module data collected through the optical branches for fault tracing and analysis. It is distinct from the converter memory unit.
  • Can the memory unit of BCU-12 3AUA0000110430 be exchanged while powered?
    No. Remove power from the control unit before removing or installing the converter memory unit.
  • What optical cable rule applies to BCU-12 3AUA0000110430?
    Fiber-optic pairs connected to one control unit must have equal lengths. Maximum lengths are 35 m for 1 mm plastic fiber and 100 m for 200 micrometre hard-clad silica fiber.
  • Why must firmware compatibility be checked for BCU-12 3AUA0000110430?
    From internal BCON-12 revision R, compatibility with older drive firmware and bootloaders is restricted. Match the hardware revision and software before replacement.
Related reading

Related cases and sourcing guidance

View all case studies
SPEAK TO OUR TEAM
Let’s find the right solution for you.
Send us the part number, quantity and delivery destination. Our team will help confirm availability and lead time.
  • Whatsapp: +86 18030235313

    Send us a message.
  • sales13@apterpower.com

    Complete our online form.
  • +86 18030235313

    Speak to our team in your native language.