Speak to a sourcing specialist
sales13@apterpower.com

DC1010CR-101000-E

DC1000 1/16 DIN Digital PID Controller with RTD Input
In Stock
Ships by Wednesday, November 11
Fast Shipping Available
Honeywell DC1010CR-101000-E PID controller, angled front view with dual displays and four keys
Honeywell DC1010CR-101000-E PID controller, rear view with terminal block and wiring label
Honeywell DC1010CR-101000-E PID controller, close-up of terminal wiring label with part number
Honeywell DC1010CR-101000-E PID controller, angled front view with dual displays and four keys
Honeywell DC1010CR-101000-E PID controller, rear view with terminal block and wiring label
Honeywell DC1010CR-101000-E PID controller, close-up of terminal wiring label with part number
Product image is representative; revision or series may vary. Contact us to request a specific version.

Product Describe:

Honeywell DC1010CR-101000-E is a 48 x 48 mm DC1000 digital PID controller with RTD input, relay control output, one alarm relay, universal AC power and English documentation.
Get a quick price for DC1010CR-101000-E
E-mail *
Mobile *
Company
Content *
Quantity *
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy

What happens after you enquire

  • 1

    Requirement review

    We review the part number, quantity and delivery requirements and ask for any missing details.
  • 2

    Quotation and availability

    We confirm the proposed item, condition, availability, price and estimated lead time in the quotation.
  • 3

    Order confirmation and dispatch

    Once the quotation and purchasing details are agreed, your contact will coordinate the order and available dispatch information.

Technical specifications for DC1010CR-101000-E

  • Product Category:
    HMI Panels
  • Spare Part Number:
    DC1010CR-101000-E
  • Estimated shipping dimensions:
    4.8×4.8×7.45cm
  • Weight:
    0.3 kg
  • Tariff Code:
    8537101190
  • Counliy of origin:
    USA
  • Controller family:
    DC1000
  • Key number:
    DC1010CR
  • Panel format:
    1/16 DIN, 48 x 48 mm
  • Input type:
    RTD
  • Power selection:
    90 to 240 Vac; CE marked
  • Program function:
    None
  • Output 1:
    SPDT relay contact, 3 A at 240 Vac
  • Output 2:
    None
  • Alarm output:
    One alarm relay
  • Transmitter output:
    None
  • Remote setpoint input:
    None
  • Communication:
    None
  • Manual language:
    English
  • Control algorithms:
    PID, ON/OFF and configurable family functions
  • Input resolution:
    14 bit
  • PV sampling time:
    250 ms
  • Digital indication accuracy:
    +/-0.2% of full scale
  • Memory:
    Non-volatile EEPROM
  • Display:
    Dual 4-digit LED with status indication
  • Operating temperature:
    0 to +50 deg C
  • Relative humidity:
    50 to 85% RH, non-condensing
  • Approvals:
    CE mark; family approvals depend on power selection

Information

Overview Manuals Common Applications Product Precautions
DC1010CR-101000-E provides compact RTD-based temperature control, relay actuation and one alarm relay for a documented process loop.
  • 48 x 48 mm DC1000 controller
  • RTD process input
  • SPDT relay control output
  • One alarm relay and English manual

The controller must remain matched to the installed RTD, relay load, alarm circuit and configured PID strategy. Commissioning restores the as-found parameters and proves indication, control and alarm response with a controlled input.

Important Notice: Confirm DC1010CR-101000-E, RTD sensor type, 90 to 240 Vac supply, relay load, alarm wiring, controller parameters and controlled input/output test evidence before commissioning.

DC1010CR-101000-E Manuals & Downloads

These documents are different: the first consolidates model-specific technical and system data; the second is the official Honeywell selection guide for the DC1000 family.

Temperature control
Regulates a documented RTD-monitored thermal process.
Heater switching
Commands the approved relay-driven heating circuit.
Machine temperature indication
Displays and alarms the configured process value.
Legacy panel maintenance
Restores an exact DC1010CR execution and settings record.
Read the applicable Honeywell installation instructions before work. Verify DC1010CR-101000-E, the installed host system and all configured field interfaces before isolation, wiring or commissioning.
1
Confirm DC1010CR-101000-E on the complete controller label.
2
Place the thermal process and final control element in the approved maintenance state.
3
Record the RTD wiring, relay load, alarm circuit and all controller parameters.
4
Isolate controller power and prove the output circuit safe before handling.
5
Match the 48 x 48 mm panel position, terminals and protective earth arrangement.
6
Restore the RTD type, scale, PID constants, setpoint, output and alarm configuration.
7
Review display, input and alarm indications after controlled energization.
8
Apply a controlled RTD simulation and record indication, output and alarm response before release.

Alternative Names

DC1010CR 101000 E DC1010CR-101000E

Technical notes

Decode the complete order as DC1010CR plus Table I 101, Table II 000 and English manual code E. Preserve the RTD wiring, relay load, alarm logic, PID configuration and setpoint values before replacement; do not transfer settings from a thermocouple or linear-input DC1000.

FAQ View All FAQ

  • How is the exact DC1010CR-101000-E execution identified?
    Decode DC1010CR with suffix 101000-E: 1/16 DIN RTD controller, relay output, one alarm relay and English manual.
  • What documented function does DC1010CR-101000-E perform?
    It performs RTD-based PID or ON/OFF temperature control with relay actuation and alarm indication.
  • Which installed system must be matched before fitting DC1010CR-101000-E?
    Match the installed RTD, relay-driven final element, alarm circuit and recorded control strategy.
  • Which interfaces must be recorded for DC1010CR-101000-E?
    Record supply, RTD terminals, relay output, alarm wiring and every configured parameter.
  • What handling controls apply to DC1010CR-101000-E?
    Isolate supply and load power, retain the as-found setup and protect the panel terminals.
  • What must be restored after installing DC1010CR-101000-E?
    Restore sensor type, scale, setpoint, PID values, output action and alarm thresholds.
  • What evidence confirms DC1010CR-101000-E is ready for service?
    Retain simulated-input indication, relay action, alarm and stable process-response results.
  • Which manufacturer record supports the DC1010CR-101000-E page?
    Honeywell's DC1000 product record and model selection guide 51-51-16-76 Issue 19a document the family and complete ordering code.
Manufacturers

You May Also Like

Explore related automation components available through Apter Power.
SPEAK TO OUR TEAM
Let’s find the right solution for you.
Send us the part number, quantity and delivery destination. Our team will help confirm availability and lead time.
  • Whatsapp: +86 18030235313

    Send us a message.
  • sales13@apterpower.com

    Complete our online form.
  • +86 18030235313

    Speak to our team in your native language.