Match the complete marking
Include ANB10D-S1 and any series, revision or assembly markings. Keep the complete reference on your enquiry and quotation. -
Check the offered item before ordering
Request available label, connector and mounting photos. Have your maintenance team compare the offered ANB10D-S1 with the installed equipment and applicable Yokogawa documentation.
Technical specifications for ANB10D-S1
-
Manufacturer:Yokogawa
-
Product Category:DCS Systems
-
Spare Part Number:ANB10D-S1
-
Weight:2.24 kg
-
Tariff Code:8537101190
-
Product series:CENTUM FIO
-
Reference design:ANB10D
-
Node communication:ESB bus
-
Base bus configuration:Dual-redundant
-
Base I/O module positions:8 maximum
-
Node interface family:SB401
-
Dual node interface arrangement:Two SB401 modules
-
Power-supply families:PW481 / PW482 / PW484, configuration-dependent
-
Base mounting:19-inch rack
-
Node functions:I/O data exchange and I/O-module power supply
Information
- Yokogawa ANB10D-S1 forms a node position between field I/O modules and the field control unit, combining the ESB communication path with the node power-distribution function.
Base bus arrangement: Dual-redundant ESB
Base I/O capacity: Up to eight modules
Mounting family: 19-inch rack
A dual-redundant node configuration uses two SB401 ESB bus interface slave modules and two suitable power-supply modules. The available power-supply families are PW481, PW482 and PW484; the fitted power modules and complete node configuration determine the required supply. The supplied ANB10D-S1 designation alone must not be used to select an AC or DC input rating.
The base unit supports up to eight I/O-module positions and uses 19-inch rack mounting. Allowable module types and allocation depend on the connected FCU, system release, node loading and environmental installation conditions. In the referenced A2FV50/A2FV70 configurations, the ANB10 node accepts communication modules only. Match the node, FCU, interface pair and installed module list as one configuration before expanding or replacing the assembly.
-
Yokogawa ANB10D-S1 technical reference
Original manufacturer excerpt. Base-design specifications and configuration requirements; match the complete offered marking. PDF, 3 pages, 209.5 KB. -
Yokogawa ANB10D-S1 installation guide
Prepared by Apter Power. Product-specific preparation, interface checks, commissioning and functional acceptance. PDF, 5 pages, 26.5 KB.
Application scope: The following uses describe the supported base-design role. Confirm ANB10D-S1 against the installed host and configuration before replacement.
-
Field I/O concentration
Group supported analog and contact I/O modules in a node and exchange their signals with the FCU through the ESB link. -
Redundant node communications
Use matched SB401 interface paths for the configured dual ESB connection, preserving both node-side paths and the FCU-side arrangement. -
Cabinet I/O expansion
Add a node only within the host release, module-allocation, power-loading and installation limits of the complete system. -
Installed node replacement
Match the actual node identity, fitted power modules and I/O inventory before restoring an existing assembly. Related node names do not establish interchangeability.
Select supply requirements from the actual PW module and node configuration, never from the shortened node marking alone.
Identify both SB401 channels and corresponding ESB connections. Do not interchange or omit a required redundant path.
Confirm the FCU and release-specific module list, including communication-only restrictions where they apply.
Use the approved rack mounting and insulation arrangement, with adequate support and access for module maintenance.
Verify module allocation, power loading and environmental limits before adding I/O or communication modules.
Test node status, communication and field-module behavior after replacement. Confirm all supplied modules and separate accessories in the quotation.
Alternative Names
Technical notes
System relationship: Verify the FCU, ESB coupler arrangement, redundant paths and permitted node configuration.
Configuration boundary: The technical data describes the ANB10D base design. Match the complete ANB10D-S1 marking, style and installed configuration; do not transfer later suffix approvals or ratings automatically.
Technical reference: Yokogawa ANB10S/ANB10D ESB Bus Node Units, GS 33J60F20-01EN, 8th edition.
FAQ View All FAQ
-
What role does ANB10D-S1 perform in a CENTUM system?The ANB10D node design transfers field I/O data to the FCU over ESB and supplies power to the installed I/O modules.
-
Is the base design of ANB10D-S1 single or dual-redundant?ANB10D is the dual-redundant ESB node design. Verify that the supplied assembly contains the matching interfaces and power modules required by the installed configuration.
-
How many I/O modules can the base design of ANB10D-S1 accommodate?The base unit has capacity for up to eight I/O modules. Actual allocation is limited by host type, power loading and installation conditions.
-
Which bus interface is used with ANB10D-S1?The ANB10D design uses SB401 ESB bus interface slave modules, with two modules in a dual-redundant configuration.
-
Can an input supply voltage be selected from the ANB10D-S1 name alone?No. Check the complete node configuration and fitted PW481, PW482 or PW484 power module before selecting the supply voltage.
-
How is the base unit of ANB10D-S1 mounted?The ANB10D design uses 19-inch rack mounting. Apply the rack support, insulation and fixing arrangement for the installed assembly.
-
Can every supported I/O type be fitted to ANB10D-S1 with any FCU?No. Module eligibility depends on the FCU and system release. In the referenced A2FV50/A2FV70 configuration, ANB10 nodes accept communication modules only.
-
What configuration must be preserved when replacing ANB10D-S1?Retain the host FCU relationship, node identity, redundant interface arrangement, fitted power-module selection and allowed I/O-module allocation.
Supporting new and legacy automation
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-
We can't find any results for “”.
You May Also Like
Product Browsing History
-
Whatsapp: +86 18030235313
Send us a message. -
sales13@apterpower.com
Complete our online form. -
+86 18030235313
Speak to our team in your native language.