Match the complete marking
Match the complete Siemens 6AV6545-0CA10-0AX0 marking, hardware execution and connection arrangement to the installed position before approving the order.
-
Check the offered item before ordering
Request clear photographs of the offered 6AV6545-0CA10-0AX0 and ask your maintenance team to compare its markings and interfaces with the installed equipment and applicable Siemens instructions.
Technical specifications for 6AV6545-0CA10-0AX0
-
Manufacturer:Siemens
-
Product Category:HMI Panels
-
Spare Part Number:6AV6545-0CA10-0AX0
-
Weight:0.74 kg
-
Tariff Code:8537101190
-
Display:5.7-inch STN; 256 colors
-
Pixel resolution:320 x 240
-
User-data memory:2048 kbyte
-
Serial interfaces:2 RS232; 1 RS422; 1 RS485
-
USB interfaces:1
-
Removable memory:CompactFlash slot
-
Typical input power:15 W
-
Rated consumption:0.6 A
-
Touch technology:Analog resistive
-
Enclosure protection:IP65 front; IP20 rear
-
Clock backup:Optional 3.6 V battery
Information
- Siemens 6AV6545-0CA10-0AX0 retains a local operator view of a serially connected controller while the project governs commands and alarm handling.
Communication role: Serial controller connection
Maintenance focus: Project recovery and alarm chronology
The project organizes process values, alarms and operator permissions within the available configuration memory. Preserve source files and the compatible engineering environment so that recovery does not depend on an unverified binary backup alone.
A battery-backed hardware clock can support consistent event timing when the optional backup arrangement is installed and healthy. Time synchronization, recipe contents and communication settings should be assessed separately from touchscreen operation.
6AV6545-0CA10-0AX0 Original Technical Excerpt
The original technical excerpt supports 6AV6545-0CA10-0AX0 configuration review. The separate Apter Power field guide organizes practical diagnostic checks. PDF · 3 pages.6AV6545-0CA10-0AX0 Installation & Verification Guide
Apter Power engineering guide for the installed signal, power or communication path and controlled acceptance. PDF · 5 pages.
Application scope: The following uses describe supported engineering roles; they do not establish interchangeability with another model or remove application-specific validation.
Preserve the TP270 engineering project, runtime compatibility information, alarm and recipe data, and the configured serial controller connection settings. Identify the controller tags behind operator commands and record the access levels required to use them. Check that the recovery method can restore the project, rather than relying on an image of the visible screens.
Place machine commands in the approved inhibited state before testing the touch interface or replacing the panel. Inspect the front seal separately from the rear cabinet connections. Check the power feed and supported CompactFlash arrangement without assuming that arbitrary removable media or a similar connector is suitable.
Restore the project and the configured serial controller connection with the correct controller endpoint. Check changing values at both the controller and panel, then compare units and tag destinations. Retain the original baseline until the new runtime and connection have been demonstrated under controlled conditions.
Generate an authorized test alarm and trace its acknowledgement back to the controller. Check a permitted setpoint or recipe transfer against controller limits and destination tags. Include optional clock-battery condition in the acceptance sequence so that a hardware-specific behavior is not concealed by a general screen test.
Restore normal operator access only after commands, indications and optional clock-battery condition have passed the agreed tests. Remove temporary test data and confirm that the production recipe and communication settings remain intact. Retain the accepted project and recovery files together with the installed TP270 hardware identity.
Use the exact hardware execution with the supported system configuration and installation conditions.
Alternative Names
Technical notes
Configuration baseline: Keep the installed SIMATIC HMI arrangement aligned with the complete 6AV6545-0CA10-0AX0 reference and its assigned system role.
Acceptance boundary: Compare the electrical or communication response with the intended application outcome before releasing maintenance controls.
Technical reference: Siemens product data sheet, 6AV6545-0CA10-0AX0. Use the exact hardware execution with the supported system configuration and installation conditions.
FAQ View All FAQ
-
Can 6AV6545-0CA10-0AX0 use the Ethernet cable from a newer HMI?This execution provides serial communication interfaces rather than an integrated Ethernet port. Confirm the actual controller link and supported driver. A newer panel with Ethernet needs a separately engineered migration; cable appearance does not establish compatibility.
-
Why can restored screens on 6AV6545-0CA10-0AX0 still operate the wrong PLC data?A valid project may contain the wrong connection address or tag mapping for the machine. Compare the configured station and test selected values against the controller online view before enabling operator commands.
-
What should be retained before changing the engineering software for 6AV6545-0CA10-0AX0?Keep an unchanged project archive, the original runtime baseline and a tested recovery method. Project conversion can affect device support and functions. Validate alarms, recipes and communication after conversion rather than relying on a successful compile alone.
-
How should clock behavior on 6AV6545-0CA10-0AX0 be checked after an outage?Confirm whether the optional backup battery is fitted and serviceable, then compare the restored clock with the intended time source. Alarm chronology must be checked independently of successful panel startup.
-
Why is the 6AV6545-0CA10-0AX0 front protection rating insufficient for cabinet assessment?The front rating applies to the correctly installed panel and seal, while the rear has a different protection level. Inspect the mounting seal and cabinet environment together. The screen rating does not protect exposed rear connectors.
-
What separates a 6AV6545-0CA10-0AX0 touch fault from a disabled command?Check touch alignment using a safe test object, then inspect permissions, interlocks and the command tag. An unavailable process action may be intentional application logic rather than a damaged touch surface.
-
How should CF-card recovery for 6AV6545-0CA10-0AX0 be validated?Confirm that the media and backup method suit the installed panel and runtime. Restore in a controlled environment and verify project identity, communication and retained data. File presence alone is not proof of a bootable or compatible recovery set.
-
What makes an alarm test on 6AV6545-0CA10-0AX0 technically complete?Verify trigger, displayed text, acknowledgement and return-to-normal behavior against the PLC. Include timestamp consistency and the relevant operator permissions. Testing only that a message appears leaves its control-side acknowledgement path unproven.
Supporting new and legacy automation
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-
We can't find any results for “”.
Related cases and sourcing guidance
View all case studiesYou May Also Like
Product Browsing History
-
Whatsapp: +86 18030235313
Send us a message. -
sales13@apterpower.com
Complete our online form. -
+86 18030235313
Speak to our team in your native language.