Technical specifications for 6SE7041-8EK85-0HA0
-
Manufacturer:Siemens
-
Product Category:Servo Drives
-
Spare Part Number:6SE7041-8EK85-0HA0
-
Estimated shipping dimensions:36.4x28.4x3.5cm
-
Weight:0.7 kg
-
Tariff Code:85049090
-
Counliy of origin:Germany
-
Component type:Rectifier interface module
-
Interface designation:PER3
-
Host function:Infeed / regenerative-feedback supply unit
-
Assigned designs:H and K
-
Host supply voltage:380-480 V, 3 AC
-
Host supply frequency:50/60 Hz
-
Lifecycle:Product cancellation
Information
Overview
Manuals
Common Applications
Product Precautions
6SE7041-8EK85-0HA0 provides the PER3 interface position within the specified SIMOVERT MASTERDRIVES infeed/regenerative-feedback supply-unit arrangement.
- Identifies the exact PER3 rectifier-interface execution
- Supports the documented infeed and regenerative-feedback host function
- Matches the defined design H or K supply-unit architecture
- Maintains the engineered interface path during controlled service
The module is installed only in the documented design H or K supply unit for 380-480 V, 3 AC at 50/60 Hz. Replacement work preserves the host-unit identity, connector pattern and existing project configuration before controlled energization.
Important Notice: Confirm 6SE7041-8EK85-0HA0, PER3, design H/K host, 380-480 V, 3 AC voltage class, 50/60 Hz supply, installed hardware revision, connector assignments, grounding, drive configuration, related accessories and controlled diagnostic results before commissioning.
Apter Power 6SE7041-8EK85-0HA0 Manuals and Guides
- Apter Power 6SE7041-8EK85-0HA0 Product Technical Reference PDF
- Apter Power 6SE7041-8EK85-0HA0 Installation, Interface and Validation Workbook PDF
The first document is the model-specific technical and system reference. The second is a distinct field workbook for installation, wiring, commissioning and acceptance records.
380-480 V design H/K interface service
Restores the PER3 position in the matching infeed/regenerative-feedback unit.
Line-side regenerative system maintenance
Supports controlled board replacement while retaining the documented host execution.
MASTERDRIVES cabinet modernization records
Preserves the exact 380-480 V board identity during lifecycle service planning.
Supply-unit diagnostic recommissioning
Provides the interface identity used for reconnection and staged diagnostic proof.
Read the applicable Siemens installation instructions before work. Verify 6SE7041-8EK85-0HA0, the installed host system and all configured field interfaces before isolation, wiring or commissioning.
1
Confirm the complete 6SE7041-8EK85-0HA0 marking and PER3 designation.
2
Verify a design H or K infeed/regenerative-feedback host before dismantling.
3
Isolate the 380-480 V supply and prove the DC link discharged.
4
Photograph every PER3 connector, cable and shield location.
5
Keep the 50/60 Hz host supply assignment with the service record.
6
Protect board contacts and connectors with ESD controls.
7
Reproduce the documented connector and grounding arrangement.
8
Perform controlled startup and verify line-side and drive diagnostics.
Alternative Names
6SE70418EK850HA0
Technical notes
Match 6SE7041-8EK85-0HA0 to the documented PER3 execution, the installed design H or K supply unit and the exact 380-480 V, 3 AC voltage class. Isolate the drive and DC link, preserve every connector assignment, then complete controlled supply-unit diagnostics before return to service.
FAQ View All FAQ
-
Which supply-unit voltage is assigned to 6SE7041-8EK85-0HA0?The Siemens article record specifies 380-480 V, 3 AC, at 50/60 Hz.
-
What interface designation belongs to 6SE7041-8EK85-0HA0?It is the PER3 rectifier-interface execution.
-
Which host construction should be confirmed for 6SE7041-8EK85-0HA0?Confirm a design H or K infeed/regenerative-feedback supply unit.
-
What should be documented before disconnecting 6SE7041-8EK85-0HA0?Capture connector positions, cable IDs, shields, grounding and installed hardware revision.
-
Can 6SE7041-8EK85-0HA0 be selected from appearance alone?No. The complete article number, PER3 designation and 380-480 V host assignment must agree.
-
How is 6SE7041-8EK85-0HA0 configured after replacement?Restore the existing approved drive and supply-unit configuration associated with the recorded host.
-
What startup checks apply to 6SE7041-8EK85-0HA0?Use controlled energization and confirm line-side, supply-unit and connected drive diagnostics.
-
What distinguishes 6SE7041-8EK85-0HA0 from the high-voltage PER3 article?Its official host assignment is 380-480 V rather than the 500-575 V / 660-690 V execution.
Manufacturers
Supporting new and legacy automation
Whether you're maintaining existing equipment or sourcing parts for current systems, we provide fast, dependable supply you can rely on.
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-
We can't find any results for “”.
PRODUCTS IN SEARCH PAGE ()
50+ account managers available now
Manufacturers
You May Also Like
Explore related automation components available through Apter Power.
Manufacturers
Product Browsing History
Revisit the products you recently viewed on Apter Power.
SPEAK TO OUR TEAM
Let’s find the right solution for you.
Send us the part number, quantity and delivery destination. Our team will help confirm availability and lead time.
-
Whatsapp: +86 18030235313
Send us a message. -
sales13@apterpower.com
Complete our online form. -
+86 18030235313
Speak to our team in your native language.