6SE7090-0XX87-4AH0

T300 Technology Board Retrofit Kit
In Stock
Ships by Tuesday, September 22
Fast Shipping Available

Product Describe:

Siemens 6SE7090-0XX87-4AH0 is a T300 technology-board retrofit kit supplied with SC58 and SC60 connection cables, the SE300 terminal block and hardware operating instructions. It adds the documented T300 technology function to the matched drive system.

Ask our team:

Get a quick price for: 6SE7090-0XX87-4AH0
Quantity*
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy.

Technical specifications for 6SE7090-0XX87-4AH0

Technical specifications for 6SE7090-0XX87-4AH0

  • Manufacturer:
    Siemens
  • Product Category:
    General Automation
  • Spare Part Number:
    6SE7090-0XX87-4AH0
  • Estimated shipping dimensions:
    16x9.8x4.5cm
  • Weight:
    0.25 kg
  • Tariff Code:
    8537101190
  • Counliy of origin:
    Germany
  • Technology board:
    T300
  • Included connection cables:
    SC58 and SC60
  • Included terminal block:
    SE300
  • Documentation:
    Hardware operating instructions

Information

Information

Overview Manuals Common Applications Product Precautions
Siemens 6SE7090-0XX87-4AH0 is a T300 technology-board retrofit kit supplied with SC58 and SC60 connection cables, the SE300 terminal block and hardware operating instructions.
  • Provides the T300 technology-board function
  • Includes the SC58 and SC60 connection cables
  • Includes the SE300 terminal block
  • Supports the documented SIMOREG DC-MASTER option arrangement

6SE7090-0XX87-4AH0 is serviced only in the documented SIMOREG DC-MASTER 6RA70 and compatible Siemens drive option system arrangement with its matching host, connector set and cabinet interfaces. Commissioning preserves the as-found configuration and verifies identity, connections, diagnostics and the affected system function.

Important Notice: Confirm 6SE7090-0XX87-4AH0, T300 board, matched SIMOREG/DC drive host, hardware revision, SC58 and SC60 cables, SE300 terminals, wiring, grounding, firmware, software configuration and controlled technology-function test results before commissioning.

Apter Power 6SE7090-0XX87-4AH0 Manuals and Guides

The first document is the model-specific technical and system reference. The second is a distinct field workbook for installation, wiring, commissioning and acceptance records.

SIMOREG technology-function retrofit
Adds the documented T300 board and companion hardware to the matched drive.
Drive control modernization
Restores an existing T300 execution with the exact retrofit-kit identity.
Terminal and cable renewal
Replaces the associated SC58, SC60 and SE300 connection set under controlled conditions.
Technology-board recommissioning
Provides the exact kit record used during drive diagnostics and functional acceptance.
Read the applicable Siemens installation instructions before work. Verify 6SE7090-0XX87-4AH0, the installed host system and all configured field interfaces before isolation, wiring or commissioning.
1
Confirm 6SE7090-0XX87-4AH0 and the T300 marking before work.
2
Place the drive and associated machine in the approved maintenance state.
3
Isolate incoming power and prove all stored energy discharged.
4
Record the installed board position, SC58/SC60 routing and SE300 terminal assignments.
5
Use ESD controls and inspect all board, cable and terminal interfaces.
6
Restore the T300 board, both connection cables and terminal block exactly as documented.
7
Restore the approved drive and technology configuration and review diagnostics.
8
Complete controlled technology-function and machine-interlock tests before service release.

Technical notes

Technical notes

Before removing 6SE7090-0XX87-4AH0, record the complete marking, installed position, mating hardware, connectors, wiring and configured function. Restore the documented Siemens arrangement, review diagnostics and complete a controlled functional test before release.

FAQS

  • What identity details must be checked before 6SE7090-0XX87-4AH0 is removed?
    Confirm 6SE7090-0XX87-4AH0, T300 board, matched SIMOREG/DC drive host, hardware revision, SC58 and SC60 cables, SE300 terminals, wiring, grounding, firmware, software configuration and controlled technology-function test results before commissioning.
  • How does 6SE7090-0XX87-4AH0 perform its documented t300 technology board retrofit kit role?
    Provides the T300 technology-board function. It adds the documented T300 technology function to the matched drive system.
  • Which SIMOREG DC-MASTER 6RA70 and compatible Siemens drive option system interfaces must be recorded for 6SE7090-0XX87-4AH0?
    6SE7090-0XX87-4AH0 is serviced only in the documented SIMOREG DC-MASTER 6RA70 and compatible Siemens drive option system arrangement with its matching host, connector set and cabinet interfaces. Commissioning preserves the as-found configuration and verifies identity, connections, diagnostics and the affected system function.
  • What isolation and ESD controls apply while handling 6SE7090-0XX87-4AH0?
    Place the drive and associated machine in the approved maintenance state. Isolate incoming power and prove all stored energy discharged.
  • How should the installed configuration be restored after fitting 6SE7090-0XX87-4AH0?
    Restore the T300 board, both connection cables and terminal block exactly as documented.
  • Which diagnostic evidence confirms that 6SE7090-0XX87-4AH0 is recognized correctly?
    Restore the approved drive and technology configuration and review diagnostics.
  • What replacement records should be retained for 6SE7090-0XX87-4AH0?
    Confirm 6SE7090-0XX87-4AH0 and the T300 marking before work. Use ESD controls and inspect all board, cable and terminal interfaces.
  • What final acceptance test is required before 6SE7090-0XX87-4AH0 returns to service?
    Complete controlled technology-function and machine-interlock tests before service release.
Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, modules and cards, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer`s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

We’re Here When You Need Us

From product insights to customer service needs, our experienced service team will focus on getting you what you need quickly

Enquire

Complete our online form.

Call Us

Speak to one of our team.

Live Chat

Send us a message.