The Siemens 6ES7288-7DP01-0AA0 is a SIMATIC S7-200 SMART EM DP01 PROFIBUS DP Slave Module that adds one PROFIBUS DP slave interface to a supported S7-200 SMART configuration.
- EM DP01 PROFIBUS DP Slave Module
- 1 PROFIBUS DP/MPI RS-485 interface
- 24 V DC; 20.4 to 28.8 V DC
- 45 x 100 x 81 mm
In a correctly engineered SIMATIC S7-200 SMART installation, it exchanges configured cyclic process data with a PROFIBUS DP master through one RS-485 PROFIBUS DP/MPI port. It works with the exact host hardware, power, wiring, field devices, firmware, and project configuration published for this complete article number. It is applied in machine cells that integrate an S7-200 SMART station as a PROFIBUS DP slave.
Important Notice: Use the complete 6ES7288-7DP01-0AA0 code and verify the physical nameplate, current Siemens documentation, supply, wiring, project, firmware, and accessories before installation or replacement.
Apter Power 6ES7288-7DP01-0AA0 Manuals and Guides
Important Notice: These are two separate Apter Power documents prepared from the manufacturer-published Siemens information named in each document. Confirm the physical nameplate, current Siemens documents, and host-system requirements before installation or replacement.
PROFIBUS DP slave station
Connects a supported S7-200 SMART station to a DP master as one engineered slave
Cyclic process-data exchange
Transfers configured input and output bytes across the PROFIBUS network
Legacy line integration
Adds a documented PROFIBUS path where Ethernet-only communication is not the required interface
Machine-cell coordination
Supports machine cells that integrate an S7-200 SMART station as a PROFIBUS DP slave after address, GSD, baud-rate, and bus engineering are verified
Read and follow the current Siemens source and applicable installation instructions before use. Verify 6ES7288-7DP01-0AA0, EM DP01 PROFIBUS DP Slave Module, host system, supply, wiring, firmware, and project from the physical installation.
1
Confirm the complete 6ES7288-7DP01-0AA0 article number and EM DP01 marking before wiring or configuration.
2
De-energize the station, then verify 24 V DC polarity and the published 20.4 to 28.8 V DC range.
3
Use PROFIBUS cable, shielding, connector pinout, network address, baud rate, GSD file, and termination exactly as engineered.
4
Terminate only the physical ends of the PROFIBUS segment and keep the station connector accessible for diagnostics.
5
Commission one data area at a time, verify byte mapping and fail-state behavior, and record the tested DP-master configuration.