The Siemens 6ES7215-1AG40-0XB0 is a SIMATIC S7-1200 CPU 1215C DC/DC/DC Compact CPU that integrates digital I/O, two analog inputs, two analog outputs, and a two-port PROFINET switch.
- CPU 1215C DC/DC/DC
- 14 DI 24 V DC; 10 DO 24 V DC; 2 AI 0 to 10 V DC; 2 AO 0 to 20 mA
- 24 V DC; 20.4 to 28.8 V DC
- 130 x 100 x 75 mm
In a correctly engineered SIMATIC S7-1200 installation, it executes machine or process logic, acquires digital and analog feedback, generates transistor and analog commands, and exchanges PROFINET data. It works with the exact host hardware, power, wiring, field devices, firmware, and project configuration published for this complete article number. It is applied in networked machines, coordinated drives, compact process skids, and control cells requiring analog commands.
Important Notice: Use the complete 6ES7215-1AG40-0XB0 code and verify the physical nameplate, current Siemens documentation, supply, wiring, project, firmware, and accessories before installation or replacement.
Apter Power 6ES7215-1AG40-0XB0 Manuals and Guides
Important Notice: These are two separate Apter Power documents prepared from the manufacturer-published Siemens information named in each document. Confirm the physical nameplate, current Siemens documents, and host-system requirements before installation or replacement.
Machine sequence control
Executes PLC logic while processing 14 di 24 v dc; 10 do 24 v dc; 2 ai 0 to 10 v dc; 2 ao 0 to 20 ma
Fast transistor output control
Commands compatible 24 V DC loads and pulse functions within the published transistor limits
Analog process acquisition
Converts the integrated 0 to 10 V inputs for limits, scaling, trends, and closed-loop logic
PROFINET automation
Coordinates HMI, distributed I/O, drives, and controllers for networked machines, coordinated drives, compact process skids, and control cells requiring analog commands
Read and follow the current Siemens source and applicable installation instructions before use. Verify 6ES7215-1AG40-0XB0, CPU 1215C DC/DC/DC, host system, supply, wiring, firmware, and project from the physical installation.
1
Confirm every character of 6ES7215-1AG40-0XB0, the CPU 1215C DC/DC/DC marking, hardware revision, and firmware against the TIA Portal project.
2
Isolate power and verify 24 V DC; 20.4 to 28.8 V DC; follow Siemens conductor, terminal, grounding, and circuit-protection requirements.
3
Check 24 V DC output polarity, 0.5 A channel limit, group current, pulse-output frequency, and load suppression before connecting field loads.
4
Separate analog and communication wiring from power conductors; terminate shields and references according to the S7-1200 system manual.
5
Restore the verified project, commission inputs and outputs by circuit group, test network and fault behavior, and record the results.