Match the complete marking
Include 6EP1336-2BA10 and any revision or approval marking visible on the item. Keep the exact reference on your enquiry and quotation. -
Check the offered item before ordering
Request available label and connector photos. Have your maintenance team compare the offered 6EP1336-2BA10 reference with the installed equipment and applicable Siemens documentation.
Technical specifications for 6EP1336-2BA10
-
Manufacturer:Siemens
-
Product Category:General Automation
-
Spare Part Number:6EP1336-2BA10
-
Weight:1.16 kg
-
Tariff Code:8537101190
-
Rated input voltage:120 / 230 V AC
-
Input ranges:85 to 132 V AC; 176 to 264 V AC
-
Line frequency:47 to 63 Hz
-
Input current:7.5 A at 120 V; 3.5 A at 230 V
-
Maximum inrush current:11 A at 25 °C
-
Rated output:24 V DC, 20 A
-
Adjustable output:24 to 28 V DC
-
Maximum output power:480 W
-
Mains buffering:20 ms
-
Residual ripple:150 mV
-
Relay contact rating:50 V DC / 0.3 A maximum
-
Short-term overload current:35 A typical
-
Overload duration:100 ms
-
Efficiency:89% at 120 V; 90% at 230 V
-
Power loss at rated load:59 W at 120 V; 53 W at 230 V
-
Parallel units:Up to 2 units
Information
- The complete 6EP1336-2BA10 order number establishes the product family and exact electrical function; verify the installed revision, wiring and companion equipment before release.
DC output: 24 V DC at 20 A; adjustable to 28 V, maximum 480 W.
Monitoring: Green 24 V OK indication and isolated normally-open signalling contact.
Input protection, conductor sizing, upstream isolation and ventilation must follow the manufacturer data and local electrical rules. Maintain the required clearances for natural convection and confirm that the installed AC source falls inside the selected operating range.
The 24 V OK LED and relay contact support local and remote status supervision, but they do not replace load-side voltage and fault checks. Commissioning should record no-load and loaded output voltage, load current, signalling state and recovery after the approved supply interruption test.
-
Siemens 6EP1336-2BA10 technical reference
Apter Power reference with verified manufacturer data and exact-model applicability. -
Siemens 6EP1336-2BA10 engineering guide
Apter Power installation, configuration, diagnostic and acceptance guidance.
Platform applications: The uses below depend on the installed controller configuration and approved system design.
-
PLC and distributed I/O power
Supply a documented 24 V DC control load within the calculated steady-state and transient demand. -
Control-panel DC distribution
Feed protected branch circuits where conductor drop, selectivity and fault energy have been reviewed. -
Sensor and actuator supply
Power compatible field devices while keeping load peaks and cable drop inside the approved design. -
Power-supply replacement
Match input range, output rating, protection, mounting and status-contact wiring before changeover.
Follow the site lockout and verification procedure before touching input or output terminals.
Confirm the actual AC source and frequency are inside the documented range.
Keep ventilation openings and required installation spaces unobstructed.
Calculate current, voltage drop and protective-device coordination for each branch.
Use only the manufacturer-approved method when supplies operate in parallel.
Measure output voltage, load current, LED and relay status under the expected operating load.
Alternative Names
Technical notes
Installation relationship: Use the exact order number and manufacturer wiring or installation data for the delivered revision.
System boundary: Verify companion equipment, field wiring and configuration before energizing.
Technical reference: Siemens Industry Mall technical data for 6EP1336-2BA10.
FAQ View All FAQ
-
How should output-current margin be calculated for 6EP1336-2BA10?Sum steady loads, startup and pulse demands, conductor losses and future allowance. Confirm the worst credible load remains within the 20 A rating and thermal installation conditions.
-
How should upstream protection be selected for 6EP1336-2BA10?Use the manufacturer input data, inrush current, conductor rating and local rules to select isolation and protection. Verify discrimination with adjacent panel devices.
-
What checks are needed before paralleling 6EP1336-2BA10?Confirm that parallel operation is permitted for the exact devices, equalize output settings and conductor impedance, and apply the manufacturer current-sharing and redundancy guidance.
-
How can the 24 V OK relay of 6EP1336-2BA10 be acceptance-tested?Monitor the contact while output is established, loaded and removed under an approved test. Compare contact state with measured output voltage rather than relying only on the green LED.
-
How should the complete marking of 6EP1336-2BA10 be recorded before removal?Photograph the full order identity, installed position, companion components and cable route. Save the stopped-machine baseline so the replacement can be returned to the same documented configuration.
-
Which compatibility check is most important before installing 6EP1336-2BA10?Confirm that every companion component belongs to the documented SITOP PSU100S 24 V DC power-supply system. Connector fit alone does not establish electrical calibration or mechanical compatibility.
-
How should cable and connector integrity be tested for 6EP1336-2BA10?Isolate the channel, inspect contacts for moisture, contamination and damage, verify continuity and insulation with an approved method, and support the cable so the connector carries no tensile load.
-
What commissioning evidence should be retained for 6EP1336-2BA10?Retain full markings, mechanical datum, companion identities, wiring or chain-length checks, as-left measurements and the operating response accepted by the maintenance authority.
Supporting new and legacy automation
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-
We can't find any results for “”.
Related cases and sourcing guidance
View all case studiesYou May Also Like
Product Browsing History
-
Whatsapp: +86 18030235313
Send us a message. -
sales13@apterpower.com
Complete our online form. -
+86 18030235313
Speak to our team in your native language.