Technical specifications for S047059 MICROLOGIC 6.0 P
-
Manufacturer:Schneider Electric
-
Product Category:General Automation
-
Spare Part Number:S047059 MICROLOGIC 6.0 P
-
Estimated shipping dimensions:21.5×7.9×6.7cm
-
Weight:0.31 kg
-
Tariff Code:8537101190
-
Counliy of origin:France
-
Product reference:S047059
-
Control-unit family:MICROLOGIC 6.0 P
-
Device class:Electronic circuit-breaker trip unit
-
Protection profile:LSIG
-
Long-time protection:Included
-
Short-time protection:Included
-
Instantaneous protection:Included
-
Ground-fault protection:Included
-
Maintenance function:ERMS supported on labeled 6.0P units
-
Service items:Rating plug and internal battery procedures documented
Information
- Long-time, short-time and instantaneous overcurrent protection
- Ground-fault protection for equipment
- Energy Reduction Maintenance Setting capability
- Local display, settings navigation and serviceable components
The Micrologic 6.0P platform combines LSIG protection with metering, alarm and event functions described in Schneider Electric's product literature. ERMS applies a separate maintenance protection setting so that an equipped breaker can trip faster during authorized energized work; the blue ERMS indication must be checked before work begins. Preserve the breaker frame, sensor rating, rating plug, protection settings, communication arrangement and existing trip history before exchanging the control unit.
Important Notice: Confirm S047059, the complete MICROLOGIC 6.0 P marking, breaker frame, sensor rating and ERMS arrangement before installation or setup.
The first document organizes exact-model technical evidence; the second provides a separate evidence-led installation and commissioning workflow.
Technical notes
FAQ View All FAQ
-
What role does S047059 MICROLOGIC 6.0 P perform?S047059 MICROLOGIC 6.0 P serves as an electronic trip unit that applies the approved protection settings in a compatible low-voltage circuit breaker.
-
Which protection functions belong to the Micrologic 6.0P profile?The Micrologic 6.0P profile provides long-time, short-time, instantaneous and ground-fault protection, commonly abbreviated as LSIG.
-
How does ERMS change operation on a MICROLOGIC 6.0 P unit?ERMS substitutes a separate set of maintenance protection settings so that an equipped breaker can clear a short circuit more quickly during authorized work.
-
What indicates that ERMS is engaged?A blue ERMS indication identifies that the maintenance setting is engaged on a correctly equipped Micrologic 6.0P arrangement.
-
Which records should be saved before replacing S047059?Technicians should preserve the breaker identity, sensor and rating-plug data, LSIG settings, alarm configuration, communications setup and trip history.
-
Can settings from another breaker be copied without comparison?Settings must not be copied until the breaker frame, sensor rating, rating plug, protection study and installed application have been verified as matching.
-
Which checks complete commissioning of MICROLOGIC 6.0 P?Commissioning is complete after the approved settings are restored, Ready and ERMS indications are verified, trip testing passes and the final protection report is recorded.
Supporting new and legacy automation
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-
We can't find any results for “”.
Related cases and sourcing guidance
View all case studiesYou May Also Like
Product Browsing History
-
Whatsapp: +86 18030235313
Send us a message. -
sales13@apterpower.com
Complete our online form. -
+86 18030235313
Speak to our team in your native language.