S047059 MICROLOGIC 6.0 P

Electronic Trip Unit
In Stock
Ships by Monday, November 9
Fast Shipping Available
Schneider S047059-MICROLOGIC-6.0-P (1)
Schneider S047059-MICROLOGIC-6.0-P (2)
Schneider S047059-MICROLOGIC-6.0-P (3)
Schneider S047059-MICROLOGIC-6.0-P (1)
Schneider S047059-MICROLOGIC-6.0-P (2)
Schneider S047059-MICROLOGIC-6.0-P (3)
Product image is representative; revision or series may vary. Contact us to request a specific version.

Product Describe:

Schneider Electric S047059 MICROLOGIC 6.0 P is a Micrologic 6.0P ERMS electronic trip unit for compatible low-voltage circuit breakers. It provides LSIG protection functions and local protection setup.
Get a quick price for S047059 MICROLOGIC 6.0 P
E-mail *
Mobile *
Company
Content *
Quantity *
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy

What happens after you enquire

  • 1

    Requirement review

    We review the part number, quantity and delivery requirements and ask for any missing details.
  • 2

    Quotation and availability

    We confirm the proposed item, condition, availability, price and estimated lead time in the quotation.
  • 3

    Order confirmation and dispatch

    Once the quotation and purchasing details are agreed, your contact will coordinate the order and available dispatch information.

Technical specifications for S047059 MICROLOGIC 6.0 P

  • Manufacturer:
    Schneider Electric
  • Product Category:
    General Automation
  • Spare Part Number:
    S047059 MICROLOGIC 6.0 P
  • Estimated shipping dimensions:
    21.5×7.9×6.7cm
  • Weight:
    0.31 kg
  • Tariff Code:
    8537101190
  • Counliy of origin:
    France
  • Product reference:
    S047059
  • Control-unit family:
    MICROLOGIC 6.0 P
  • Device class:
    Electronic circuit-breaker trip unit
  • Protection profile:
    LSIG
  • Long-time protection:
    Included
  • Short-time protection:
    Included
  • Instantaneous protection:
    Included
  • Ground-fault protection:
    Included
  • Maintenance function:
    ERMS supported on labeled 6.0P units
  • Service items:
    Rating plug and internal battery procedures documented

Information

Overview Manuals Common Applications Product Precautions
At the circuit-breaker interface, S047059 MICROLOGIC 6.0 P supervises protection settings, trip information and the controlled use of the ERMS maintenance mode.
  • Long-time, short-time and instantaneous overcurrent protection
  • Ground-fault protection for equipment
  • Energy Reduction Maintenance Setting capability
  • Local display, settings navigation and serviceable components

The Micrologic 6.0P platform combines LSIG protection with metering, alarm and event functions described in Schneider Electric's product literature. ERMS applies a separate maintenance protection setting so that an equipped breaker can trip faster during authorized energized work; the blue ERMS indication must be checked before work begins. Preserve the breaker frame, sensor rating, rating plug, protection settings, communication arrangement and existing trip history before exchanging the control unit.

Important Notice: Confirm S047059, the complete MICROLOGIC 6.0 P marking, breaker frame, sensor rating and ERMS arrangement before installation or setup.

Schneider Electric S047059 MICROLOGIC 6.0 P Manuals & Downloads
Schneider Electric S047059 MICROLOGIC 6.0 P Technical Reference (PDF)Schneider Electric S047059 MICROLOGIC 6.0 P Installation & Commissioning Guide (PDF)

The first document organizes exact-model technical evidence; the second provides a separate evidence-led installation and commissioning workflow.

Circuit-breaker protection
Applies the approved LSIG protection settings for a compatible breaker and installation.
ERMS maintenance operation
Provides a separate reduced protection setting during an authorized maintenance procedure.
Protection-event review
Supports local inspection of trip, alarm and operating information through the Micrologic display.
Installed trip-unit replacement
Restores the documented breaker protection arrangement after settings and hardware compatibility are verified.
Read the applicable Schneider Electric instructions before work. Verify S047059 MICROLOGIC 6.0 P and the installed system configuration before isolation or replacement.
1
Record S047059, the complete MICROLOGIC 6.0 P marking and breaker identification.
2
Use the approved electrical safe-work and isolation procedure before handling the trip unit.
3
Export or transcribe every LSIG, alarm, metering and communication setting before removal.
4
Verify the breaker frame, sensor rating, rating plug and control-power arrangement.
5
Confirm the ERMS switch or I/O arrangement and check the blue ERMS indication.
6
Inspect the trip-unit connector, rating plug, battery and retention points before installation.
7
Restore the approved settings and perform the specified primary or secondary injection tests.
8
Document the final settings, indications, trip results and return-to-service authorization.

Technical notes

Back up all protection, metering, alarm and communication settings before removal. After installation, restore the approved LSIG and ERMS configuration, verify the Ready and ERMS indications, test the trip chain under the approved procedure and retain the final settings report.

FAQ View All FAQ

  • What role does S047059 MICROLOGIC 6.0 P perform?
    S047059 MICROLOGIC 6.0 P serves as an electronic trip unit that applies the approved protection settings in a compatible low-voltage circuit breaker.
  • Which protection functions belong to the Micrologic 6.0P profile?
    The Micrologic 6.0P profile provides long-time, short-time, instantaneous and ground-fault protection, commonly abbreviated as LSIG.
  • How does ERMS change operation on a MICROLOGIC 6.0 P unit?
    ERMS substitutes a separate set of maintenance protection settings so that an equipped breaker can clear a short circuit more quickly during authorized work.
  • What indicates that ERMS is engaged?
    A blue ERMS indication identifies that the maintenance setting is engaged on a correctly equipped Micrologic 6.0P arrangement.
  • Which records should be saved before replacing S047059?
    Technicians should preserve the breaker identity, sensor and rating-plug data, LSIG settings, alarm configuration, communications setup and trip history.
  • Can settings from another breaker be copied without comparison?
    Settings must not be copied until the breaker frame, sensor rating, rating plug, protection study and installed application have been verified as matching.
  • Which checks complete commissioning of MICROLOGIC 6.0 P?
    Commissioning is complete after the approved settings are restored, Ready and ERMS indications are verified, trip testing passes and the final protection report is recorded.
Manufacturers

Product Browsing History

Revisit the products you recently viewed on Apter Power.
SPEAK TO OUR TEAM
Let’s find the right solution for you.
Send us the part number, quantity and delivery destination. Our team will help confirm availability and lead time.
  • Whatsapp: +86 18030235313

    Send us a message.
  • sales13@apterpower.com

    Complete our online form.
  • +86 18030235313

    Speak to our team in your native language.