Match the complete marking
Include VT-VSPA1-1-F10 and the visible revision or assembly identity in your enquiry. Keep the complete reference on the quotation.
-
Check the offered item before ordering
Request available label and connector photos. Have your maintenance team compare the offered VT-VSPA1-1-F10 with the installed equipment and applicable Rexroth documentation.
Technical specifications for VT-VSPA1-1-F10
-
Manufacturer:Rexroth
-
Product Category:General Automation
-
Spare Part Number:VT-VSPA1-1-F10
-
Weight:0.1 kg
-
Tariff Code:8537101190
-
Nameplate material number:00033823
-
Nameplate revision:R09
-
Amplifier family:VT-VSPA1-1, component series 1X
-
Control application:Proportional pressure valve with one solenoid
-
Supply, series data:24 V DC (+40% / -5%)
-
Connector, series data:32-pole DIN 41612 card connector with front plate
-
Command inputs, series data:Voltage/current-selectable differential input and +9 V input
-
Ramp, series data:Separate upward and downward ramp adjustments
-
Indication:H2 ready-for-operation LED on front plate
Information
- Rexroth VT-VSPA1-1-F10. For VT-VSPA1-1-F10, retain the existing valve pairing, command source and front-panel settings when exchanging the amplifier card.
Nameplate material number: 00033823
Nameplate revision: R09
Amplifier family: VT-VSPA1-1, component series 1X
The F10 card belongs to an installed hydraulic control loop. Match the valve, input-signal mode, DIL-switch positions and ramp settings to that loop before commissioning.
The F10 marking and revision remain part of the purchase identity. An adjacent VT-VSPA1-1 code should only be considered after a documented equipment-level comparison.
-
Rexroth VT-VSPA1-1-F10 technical reference
Original manufacturer excerpt - PDF, 3 pages. VT-VSPA1-1 series 1X specifications and front-panel controls. -
Rexroth VT-VSPA1-1-F10 installation guide
Prepared by Apter Power - PDF, 5 pages. Installed-system review, configuration checks, commissioning and handover.
Application scope: Apply its command, ramp and ready functions after matching the F10/R09 marking and saved settings to the hydraulic loop.
-
Pressure-valve control
The VT-VSPA1-1 series serves a one-solenoid proportional pressure valve without electrical position feedback. -
Card and supply fit
The documented series uses a 32-pole DIN 41612 card connector and 24 V DC supply. -
Command interface
Series data describes a selectable voltage/current differential command input and a +9 V input. -
Ramp control
Separate upward and downward ramp adjustments shape the valve command in the installed loop.
De-energize the card supply and hydraulic actuator control before removal.
Verify voltage/current input selection before energizing the replacement.
Check the valve type and installed switch positions before transferring settings.
Verify the 24 V DC card supply and rack polarity before insertion.
Record the Gw maximum-command control and both ramp positions before removing the old card.
Check H2 ready status, command tracking and valve response under the site procedure.
Alternative Names
Technical notes
Installation relationship: Match the complete F10 card marking and R09 revision with the installed hydraulic valve and rack before replacement.
Configuration: Set command-input mode, DIL switches, maximum command and ramp controls to the documented installation.
Technical reference: Mannesmann Rexroth Electrical Amplifiers VT-VSPA1-1 and VT-VSPA1K-1, RD 30 111/03.98.
FAQ View All FAQ
-
What is the function of VT-VSPA1-1-F10?It is a VT-VSPA1-1-family amplifier card for controlling a one-solenoid proportional pressure valve. Match the valve and settings to the installed system.
-
Which marking identifies the offered VT-VSPA1-1-F10?The supplied nameplate reads VT-VSPA1-1-F10, material number 00033823 and revision R09.
-
What supply does the VT-VSPA1-1 series specify for VT-VSPA1-1-F10?The Rexroth 1X series document specifies 24 V DC with a +40% / -5% operating tolerance; verify the installed supply and card marking before connection.
-
What connector arrangement is documented for the VT-VSPA1-1 family of VT-VSPA1-1-F10?The VT-VSPA1-1 form uses a 32-pole card connector and front plate. Check the rack slot, wiring and complete card marking.
-
How are pressure-valve command signals handled by VT-VSPA1-1-F10?The family document describes a differential command input selectable between voltage and current modes, plus an additional +9 V command input. Set the switches for the installed signal source.
-
What do the two front ramp controls on VT-VSPA1-1-F10 do?The VT-VSPA1-1 front panel has separate upward and downward ramp adjustments. Transfer the installed settings only after confirming the valve application.
-
What does the H2 indicator on VT-VSPA1-1-F10 represent?The H2 front LED indicates ready-for-operation status in the documented VT-VSPA1-1 arrangement; verify the input and solenoid circuit if it is not ready.
-
Can another VT-VSPA1-1 variant automatically replace VT-VSPA1-1-F10?No. Preserve the complete F10 marking, material number, card revision, valve pairing and switch configuration when choosing a replacement.
Supporting new and legacy automation
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-
We can't find any results for “”.
You May Also Like
Product Browsing History
-
Whatsapp: +86 18030235313
Send us a message. -
sales13@apterpower.com
Complete our online form. -
+86 18030235313
Speak to our team in your native language.