FBM214 P0914XQ

HART Input Module
In Stock
Ships by Saturday, November 7
Fast Shipping Available
Product image is representative; revision or series may vary. Contact us to request a specific version.

Product Describe:

Foxboro FBM214 P0914XQ is a hart communication input module for 4 to 20 mA measurement with bidirectional HART messaging. It operates with the HART termination assembly, loop power and I/A Series database and provides eight HART-capable input loops.
Get a quick price for FBM214 P0914XQ
E-mail *
Mobile *
Company
Content *
Quantity *
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy

What happens after you enquire

  • 1

    Requirement review

    We review the part number, quantity and delivery requirements and ask for any missing details.
  • 2

    Quotation and availability

    We confirm the proposed item, condition, availability, price and estimated lead time in the quotation.
  • 3

    Order confirmation and dispatch

    Once the quotation and purchasing details are agreed, your contact will coordinate the order and available dispatch information.

Technical specifications for FBM214 P0914XQ

  • Manufacturer:
    Invensys
  • Product Category:
    DCS Systems
  • Spare Part Number:
    FBM214 P0914XQ
  • Estimated shipping dimensions:
    4.5x10.8x11.5cm
  • Weight:
    0.32 kg
  • Tariff Code:
    8537101190
  • Counliy of origin:
    USA
  • Input channels:
    8 group-isolated analog inputs
  • Analog signal:
    4 to 20 mA
  • Digital communication:
    HART FSK superimposed on the analog signal
  • Conversion:
    Analog-to-digital conversion for each loop
  • Channel power:
    Common isolated supply or controlled external supply

Information

Overview Manuals Common Applications Product Precautions
Foxboro FBM214 P0914XQ provides eight group-isolated 4 to 20 mA inputs with superimposed HART FSK communication for intelligent field transmitters.
  • Provides eight HART-capable input loops for its hart communication input module function.
  • Handles 4 to 20 mA measurement with bidirectional HART messaging through the documented Foxboro system path.
  • Works with the HART termination assembly, loop power and I/A Series database.
  • A dedicated FSK modem supports digital communication with each connected HART device.

The hart communication input module belongs in the controlled Foxboro architecture and works with the HART termination assembly, loop power and I/A Series database. Its mating hardware, wiring, database configuration and final response must be checked together before release.

Important Notice: Use FBM214 P0914XQ only with the HART termination assembly, loop power and I/A Series database; verify every interface and the controlled project configuration before energizing or pressurizing the subsystem.

Foxboro FBM214 P0914XQ Manuals & Downloads
Foxboro FBM214 P0914XQ Official Technical Reference Excerpt (PDF)Foxboro FBM214 P0914XQ Installation & Commissioning Guide (PDF)

The first document covers the product function, system role and technical selection. The installation guide covers identification, connection checks, commissioning and the acceptance record.

System maintenance
Restores the documented hart communication input module function in an existing Foxboro control system.
Signal-path service
Supports controlled testing of 4 to 20 mA measurement with bidirectional HART messaging at the assigned system position.
Planned replacement
Provides an exact-identity replacement path after the HART termination assembly, loop power and I/A Series database has been verified.
Commissioning
Allows the responsible engineer to prove configuration, diagnostics and response for eight HART-capable input loops.
Before installing Foxboro FBM214 P0914XQ, confirm the documented system, interfaces and controlled configuration.
1
Match the complete FBM214 P0914XQ marking to the work order and installed position before removal.
2
Confirm the HART termination assembly, loop power and I/A Series database before disconnecting any interface.
3
Keep 4 to 20 mA measurement with bidirectional HART messaging within the documented electrical or pneumatic range.
4
Record terminal designations, polarity, common, shield and cable routing before disconnection.
5
Inspect mounting, connector keying, terminal condition and retention hardware before installation.
6
Restore the controlled database, range, alarm, filter and fail-state settings before energization.
7
Review local indicators and controller diagnostics during the controlled startup sequence.
8
Prove the intended response across eight HART-capable input loops and record the acceptance result before release.

Technical notes

Use FBM214 P0914XQ only with the HART termination assembly, loop power and I/A Series database; verify every interface and the controlled project configuration before energizing or pressurizing the subsystem.

FAQ View All FAQ

  • Which signals can Foxboro FBM214 P0914XQ receive?
    Each channel accepts a 4 to 20 mA analog input with optional HART FSK communication superimposed.
  • How many HART devices can connect to Foxboro FBM214 P0914XQ?
    Eight input channels are provided, each with its own HART communication path.
  • What isolation arrangement does Foxboro FBM214 P0914XQ use?
    The eight input channels are group isolated from ground and module logic.
  • How may field devices connected to Foxboro FBM214 P0914XQ be powered?
    The common isolated module supply may power the loops, or an approved external supply may be used with the required crosstalk controls.
  • Why can Foxboro FBM214 P0914XQ require a Cable Balun with external supplies?
    It reduces channel crosstalk when a common external source powers multiple HART loops.
  • Which HART values should be checked while commissioning Foxboro FBM214 P0914XQ?
    Verify the analog primary value, digital device identity, diagnostics and bidirectional command response.
  • Is Foxboro FBM214 P0914XQ the current FBM214 part number?
    It is the legacy FBM214 ordering code; newer documentation also lists later FBM214 part-number executions.
  • What prevents an incorrect substitution for Foxboro FBM214 P0914XQ?
    Match the complete P0914XQ identity, isolation architecture, termination assembly, loop power and database configuration.
Related reading

Related cases and sourcing guidance

View all case studies
Manufacturers

Product Browsing History

Revisit the products you recently viewed on Apter Power.
SPEAK TO OUR TEAM
Let’s find the right solution for you.
Send us the part number, quantity and delivery destination. Our team will help confirm availability and lead time.
  • Whatsapp: +86 18030235313

    Send us a message.
  • sales13@apterpower.com

    Complete our online form.
  • +86 18030235313

    Speak to our team in your native language.