Technical specifications for T3481
-
Manufacturer:ICS Triplex
-
Product Category:DCS Systems
-
Spare Part Number:T3481
-
Estimated shipping dimensions:3.3x26.5x35.5cm
-
Weight:1.72 kg
-
Tariff Code:8537101101
-
Counliy of origin:USA
-
Product Type:Regent Monitored Guarded 24 Vdc Output Module
-
System Family:Regent
-
Channel / Interface Summary:16 monitored outputs in two groups of eight; 18–36 Vdc
-
Signal Role:24 Vdc discrete load current with monitored output and fault status
-
Country of origin:Verify the physical nameplate and current Rockwell Automation order record
-
Official Source:Rockwell Automation ICSTT-RM021-EN-P (PD-6033)
Information
- AADvance Processor Module
- Executes the safety application and coordinates I/O
- Application, diagnostic and configured communications data
- AADvance controller base and approved system architecture
It executes the safety application, coordinates I/O, diagnostics and controller communications. It handles application variables, I/O data, diagnostic records and configured Ethernet/serial traffic and operates with T9100 processor base unit, AADvance Workbench or AADvance-Trusted SIS Workstation, T9300 I/O base units. Verify the exact hardware revision, matched termination and controlled application records before commissioning.
Apter Power T3481 Manuals and Guides
- Apter Power T3481 Product Reference Manual
- Apter Power T3481 Installation and Verification Reference
Important Notice: These are two separate Apter Power documents prepared from the official ICS Triplex source named in each document. Confirm the physical nameplate, current Rockwell Automation documentation, and applicable installation instructions before installation or replacement.
Alternative Names
Technical notes
FAQ View All FAQ
-
What is the ICS Triplex T3481?It is a Regent Monitored Guarded 24 Vdc Output Module for the Regent system.
-
What does T3481 do?switches and monitors sixteen 24 Vdc loads while reporting load and fuse faults to the Regent controller.
-
What signals or data does it handle?24 Vdc discrete load current with monitored output and fault status.
-
Which components are compatible?Regent I/O chassis, matching terminal blocks, field supply and WINTERPRET configuration.
-
Where is it commonly applied?Shutdown solenoids, Trip relays, Alarm annunciators, Burner management outputs, Fault-tolerant final elements.
-
What must be checked before replacement?Confirm the exact model, revision, slot keying, termination assembly, field wiring, configuration, firmware and current official manual before commissioning.
Supporting new and legacy automation
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-
We can't find any results for “”.
Related cases and sourcing guidance
View all case studiesYou May Also Like
Product Browsing History
-
Whatsapp: +86 18030235313
Send us a message. -
sales13@apterpower.com
Complete our online form. -
+86 18030235313
Speak to our team in your native language.