Match the complete marking
Include MU-TDID12 51304441-125 and every revision or approval marking visible on the item. Keep the exact reference on your enquiry and quotation.
-
Check the offered item before ordering
Request available label and interface photos. Have your maintenance team compare the offered MU-TDID12 51304441-125 with the installed equipment and applicable Honeywell documentation.
Technical specifications for MU-TDID12 51304441-125
-
Manufacturer:Honeywell
-
Product Category:DCS Systems
-
Spare Part Number:MU-TDID12 51304441-125
-
Weight:1.18 kg
-
Tariff Code:8537101190
-
Field input class:24 V DC
-
Digital input channels:32
-
Planning supply basis:24 V DC
-
Assembly current for power planning:408 mA
-
Terminal construction:Compression
-
Mounting class:C
Information
- MU-TDID12 uses compression terminals. MU-TDID52 uses fixed screw terminals and MU-TDID72 uses removable screw terminals with a single-IOP configuration. The 51304441-125 assembly is the CE execution, distinct from 51304441-100.
Compression-terminal servicing: Field conductor connections can be reviewed against recorded terminal assignments.
Defined execution selection: Cabinet compliance and terminal construction are checked together during replacement.
The documented compression-terminal version differs mechanically from the MU-TDID52 fixed-screw and MU-TDID72 removable-screw versions. Terminal construction affects conductor handling and replacement work even where the nominal field-signal class appears similar.
Honeywell assigns a 408 mA assembly-current value in its 24 V DC planning table for MU-TDID12/52. Use that value for the documented cabinet power budget, with the processor and other assemblies accounted for separately. The planning figure does not establish the allowable load on an individual field input.
Honeywell 24 V DC Digital Input FTA Excerpt
Original power-planning, terminal-selection and exact CE assembly identification pages.MU-TDID12 51304441-125 Digital Input Field Guide
Field voltage checks, terminal mapping, current-budget interpretation and input-state acceptance.
Application scope: Terminal construction and cabinet compliance form part of the installation choice. Match them with the complete assembly code and the existing wiring record.
Discrete state acquisition
Terminate the documented 24 V DC field input groups before input processing.Cabinet power planning
Include the assembly-current allowance in the complete cabinet calculation.Compression-terminal maintenance
Capture conductor positions and terminal condition for a controlled FTA exchange.Legacy input restoration
Prove actual switch-state indications against the original channel assignment after replacement.
Verify the installed inputs belong to the 24 V DC family before touching field wiring.
Record terminal positions, conductor identifiers and their associated input points.
Check conductor retention and terminal damage using the approved service method.
Account for the FTA and processor loads independently.
Confirm -125 against the installed CE configuration and retain its revision record.
Verify representative active and inactive field states at the receiving system after restoration.
Alternative Names
Technical notes
Current interpretation: 408 mA is the assembly-current entry in the 24 V DC power-planning table, rather than a per-input field current.
Terminal alternatives: MU-TDID52 uses fixed screw terminals. MU-TDID72 uses removable screw terminals and is listed for a single IOP.
Compliance execution: The -125 part is the CE-compliant nonconformally coated assembly. The -100 part is the non-CE version.
FAQ View All FAQ
-
Can MU-TDID12 51304441-125 be selected for a 120 V field input?Its documented input class is 24 V DC. Verify the field supply and wiring drawing because the higher-voltage DI families have different complete model identities.
-
Does the planning current of MU-TDID12 51304441-125 define its per-channel input limit?The 408 mA entry is an assembly power-planning value at the stated supply basis. Use it for cabinet budgeting and obtain the applicable input electrical specification before assessing individual channel loading.
-
What changes when replacing MU-TDID12 51304441-125 with a screw-terminal version?The terminal mechanism and potentially the IOP arrangement change. Compare conductor handling, terminal assignment and full model selection before approving a different version.
-
How is the CE execution of MU-TDID12 51304441-125 distinguished?The exact -125 assembly is listed as the CE-compliant version. Check the complete part marking and the installed cabinet conditions rather than relying on the shared MU-TDID12 model text.
-
Which evidence should be captured before disconnecting MU-TDID12 51304441-125?Photograph terminal labels, conductor identifiers, connector locations and the full assembly revision. Associate each wire with its control-system input point so reconnection can be checked independently.
-
How should MU-TDID12 51304441-125 be tested after conductor restoration?Under the approved plant procedure, compare representative active and inactive field states with the receiving-system indications. Resolve inverted or misplaced points before the affected inputs resume normal service.
-
What should be reviewed if several MU-TDID12 51304441-125 inputs fail together?Review common field supply, connector seating and shared wiring paths before attributing the symptom to separate switches. Compare the affected group with the documented terminal map.
-
Why should the single-IOP alternative be reviewed separately from MU-TDID12 51304441-125?MU-TDID72 is explicitly identified as a single-IOP FTA and uses removable screw terminals. Confirm the processor configuration and termination method together before considering substitution.
Supporting new and legacy automation
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-