Get Parts Quote
Name
Company *
Phone *
Email *
Address
City
State / Province / Region
Zipcode
Country
Quantity *
Part Number *
Manufacturer
Preferred Condition
Additional Information
Cancel

FC-UGAO01

Universal Marshalling Analog Output Isolator
In Stock
Ships by Monday, September 21
Fast Shipping Available

Product Describe:

Honeywell FC-UGAO01 is universal marshalling analog output isolator. It provides an isolated intrinsically safe analog-output path within a Universal Marshalling System safety assembly.

Ask our team:

Get a quick price for: FC-UGAO01
Quantity*
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy.

Technical specifications for FC-UGAO01

Technical specifications for FC-UGAO01

  • Manufacturer:
    Honeywell
  • Product Category:
    Machinery Monitoring System
  • Spare Part Number:
    FC-UGAO01
  • Estimated shipping dimensions:
    3.5x22.8x17.5cm
  • Weight:
    0.7 kg
  • Tariff Code:
    8537101190
  • Counliy of origin:
    USA
  • Function:
    Analog output isolator
  • Safety integrity:
    SIL 2
  • Intrinsic safety:
    IS
  • Approval status:
    TUV approved
  • UMS assembly capacity:
    16 channels
  • Assembly size:
    137 x 140 x 198 mm

Information

Information

Overview Manuals Common Applications Product Precautions
Honeywell FC-UGAO01 is universal marshalling analog output isolator. It provides an isolated intrinsically safe analog-output path within a Universal Marshalling System safety assembly.
  • Performs the UMS analog-output isolator role
  • Supports SIL 2 safety applications
  • Provides an intrinsically safe field interface
  • Occupies one channel position in a 16-channel UMS assembly

FC-UGAO01 operates with UMS Safety assembly, configured analog-output field loop, approved termination hardware, Safety Manager project and test record.

Engineered applications include SIL 2 final-element command, Hazardous-area analog actuation, Universal marshalling cabinet build, Safety-loop output renewal.

Important Notice: Confirm the UMS channel assignment, barrier/isolator type, loop polarity, field grounding and safety application proof-test procedure before energization.

Apter Power FC-UGAO01 Manuals and Guides

Apter Power FC-UGAO01 Product and System Technical Reference PDFApter Power FC-UGAO01 Field Installation and Functional Acceptance Workbook PDF

The first document organizes model-specific identity, technical data and system context. The second provides a separate installation, connection, commissioning and acceptance workflow.

SIL 2 final-element command

Isolates the commanded analog path to a safety final element.

Hazardous-area analog actuation

Interfaces an intrinsically safe actuator loop in a classified area.

Universal marshalling cabinet build

Standardizes analog-output termination inside a UMS enclosure.

Safety-loop output renewal

Restores a documented isolator without changing the validated safety function.

Read the applicable Honeywell instructions before work. Verify FC-UGAO01 and the installed Honeywell UMS Safety configuration.
1

Verify the complete FC-UGAO01 marking and its assigned UMS analog-output isolator position before work.

2

Place the connected process and control strategy in the approved maintenance state.

3

Isolate the applicable cabinet supply and analog-output field energy before disconnecting conductors.

4

Record terminal numbers, channel assignments, polarity, shields and configured ranges before removal.

5

Use ESD controls and protect the backplane connector, terminal hardware and coated electronics.

6

Confirm the installed UMS Safety assembly and carrier arrangement against the approved project.

7

Restore power in a controlled sequence and clear only diagnostics created by the maintenance activity.

8

Complete the approved SIL 2 loop proof test and retain the measured result before returning the channel to automatic service.

Technical notes

Technical notes

Confirm the UMS channel assignment, barrier/isolator type, loop polarity, field grounding and safety application proof-test procedure before energization.

FAQS

  • What exact Honeywell system position is intended for FC-UGAO01?
    FC-UGAO01 is assigned to the documented Honeywell UMS Safety role as universal marshalling analog output isolator; confirm that role against the installed cabinet record.
  • Which field signal or controlled function is handled by FC-UGAO01?
    Its documented signal duty is isolated intrinsically safe analog-output signal. The controlling source lists safety integrity as SIL 2.
  • Which companion hardware must be checked before installing FC-UGAO01?
    Match FC-UGAO01 with UMS Safety assembly and configured analog-output field loop; also retain the approved carrier, cable and project identity.
  • What electrical limit should an engineer verify before wiring FC-UGAO01?
    Verify the model-specific value for Approval status: TUV approved. Do not transfer a limit from another module revision.
  • How should the installed configuration be preserved when replacing FC-UGAO01?
    Record the as-found slot, connector, channel assignment and project revision, then restore only the approved Honeywell UMS Safety configuration.
  • Which isolation or handling check applies to FC-UGAO01?
    Apply the isolation and ESD sequence stated for FC-UGAO01; the source also identifies assembly size as 137 x 140 x 198 mm.
  • What diagnostic or commissioning evidence is required for FC-UGAO01?
    Complete the model-specific functional check for sil 2 final-element command, review host diagnostics and retain the final test result.
  • Can FC-UGAO01 be substituted for a visually similar Honeywell assembly?
    No automatic substitution is assumed. Compare the complete FC-UGAO01 marking, function, companion hardware, signal duty and approved system revision.
Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, modules and cards, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer`s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.