Technical specifications for FC-UGAO01
-
Manufacturer:Honeywell
-
Product Category:Machinery Monitoring Systems
-
Spare Part Number:FC-UGAO01
-
Estimated shipping dimensions:3.5x22.8x17.5cm
-
Weight:0.7 kg
-
Tariff Code:8537101190
-
Counliy of origin:USA
-
Function:Analog output isolator
-
Safety integrity:SIL 2
-
Intrinsic safety:IS
-
Approval status:TUV approved
-
UMS assembly capacity:16 channels
-
Assembly size:137 x 140 x 198 mm
Information
- Performs the UMS analog-output isolator role
- Supports SIL 2 safety applications
- Provides an intrinsically safe field interface
- Occupies one channel position in a 16-channel UMS assembly
FC-UGAO01 operates with UMS Safety assembly, configured analog-output field loop, approved termination hardware, Safety Manager project and test record.
Engineered applications include SIL 2 final-element command, Hazardous-area analog actuation, Universal marshalling cabinet build, Safety-loop output renewal.
Important Notice: Confirm the UMS channel assignment, barrier/isolator type, loop polarity, field grounding and safety application proof-test procedure before energization.
Apter Power FC-UGAO01 Manuals and Guides
Apter Power FC-UGAO01 Product and System Technical Reference PDFApter Power FC-UGAO01 Field Installation and Functional Acceptance Workbook PDFThe first document organizes model-specific identity, technical data and system context. The second provides a separate installation, connection, commissioning and acceptance workflow.
SIL 2 final-element command
Isolates the commanded analog path to a safety final element.
Hazardous-area analog actuation
Interfaces an intrinsically safe actuator loop in a classified area.
Universal marshalling cabinet build
Standardizes analog-output termination inside a UMS enclosure.
Safety-loop output renewal
Restores a documented isolator without changing the validated safety function.
Verify the complete FC-UGAO01 marking and its assigned UMS analog-output isolator position before work.
Place the connected process and control strategy in the approved maintenance state.
Isolate the applicable cabinet supply and analog-output field energy before disconnecting conductors.
Record terminal numbers, channel assignments, polarity, shields and configured ranges before removal.
Use ESD controls and protect the backplane connector, terminal hardware and coated electronics.
Confirm the installed UMS Safety assembly and carrier arrangement against the approved project.
Restore power in a controlled sequence and clear only diagnostics created by the maintenance activity.
Complete the approved SIL 2 loop proof test and retain the measured result before returning the channel to automatic service.
Technical notes
FAQ View All FAQ
-
What exact Honeywell system position is intended for FC-UGAO01?FC-UGAO01 is assigned to the documented Honeywell UMS Safety role as universal marshalling analog output isolator; confirm that role against the installed cabinet record.
-
Which field signal or controlled function is handled by FC-UGAO01?Its documented signal duty is isolated intrinsically safe analog-output signal. The controlling source lists safety integrity as SIL 2.
-
Which companion hardware must be checked before installing FC-UGAO01?Match FC-UGAO01 with UMS Safety assembly and configured analog-output field loop; also retain the approved carrier, cable and project identity.
-
What electrical limit should an engineer verify before wiring FC-UGAO01?Verify the model-specific value for Approval status: TUV approved. Do not transfer a limit from another module revision.
-
How should the installed configuration be preserved when replacing FC-UGAO01?Record the as-found slot, connector, channel assignment and project revision, then restore only the approved Honeywell UMS Safety configuration.
-
Which isolation or handling check applies to FC-UGAO01?Apply the isolation and ESD sequence stated for FC-UGAO01; the source also identifies assembly size as 137 x 140 x 198 mm.
-
What diagnostic or commissioning evidence is required for FC-UGAO01?Complete the model-specific functional check for sil 2 final-element command, review host diagnostics and retain the final test result.
-
Can FC-UGAO01 be substituted for a visually similar Honeywell assembly?No automatic substitution is assumed. Compare the complete FC-UGAO01 marking, function, companion hardware, signal duty and approved system revision.
Supporting new and legacy automation
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-
We can't find any results for “”.
You May Also Like
Product Browsing History
-
Whatsapp: +86 18030235313
Send us a message. -
sales13@apterpower.com
Complete our online form. -
+86 18030235313
Speak to our team in your native language.