Get Parts Quote
Name
Company *
Phone *
Email *
Address
City
State / Province / Region
Zipcode
Country
Quantity *
Part Number *
Manufacturer
Preferred Condition
Additional Information
Cancel

FC-TSHART-1620M

Sixteen-Channel Safe HART Input FTA
In Stock
Ships by Thursday, September 17
Fast Shipping Available

Product Describe:

Honeywell FC-TSHART-1620M is a Sixteen-Channel Safe HART Input FTA. It conditions transmitter loops for an SAI-1620m module and presents the HART signal to a multiplex unit.

Ask our team:

Get a quick price for: FC-TSHART-1620M
Quantity*
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy.

Technical specifications for FC-TSHART-1620M

Technical specifications for FC-TSHART-1620M

  • Manufacturer:
    Honeywell
  • Product Category:
    DCS System
  • Spare Part Number:
    FC-TSHART-1620M
  • Estimated shipping dimensions:
    25x7x5.8cm
  • Weight:
    0.36 kg
  • Tariff Code:
    8537101190
  • Counliy of origin:
    USA
  • Input channels:
    16; 2 groups of 8
  • External supply:
    30 Vdc; 3 mA without loop loads
  • Input current:
    0 to 25 mA
  • Input resistance:
    250 ohm +/-1%
  • Output to SAI-1620m:
    0 to 4 Vdc
  • Accuracy:
    0.10%
  • HART multiplex output:
    5 V peak-to-peak maximum
  • Fuse:
    315 mA

Information

Information

Overview Manuals Common Applications Product Precautions
Honeywell FC-TSHART-1620M is a 16-channel safe HART input FTA. It conditions transmitter loops for an SAI-1620m module and presents the HART signal to a multiplex unit.
  • Terminates safety-related analog input loops
  • Provides HART multiplex access
  • Interfaces passive transmitters to SAI-1620m
  • Organizes field loops around documented common references

FC-TSHART-1620M installs with SAI-1620m safe analog input module, 30 Vdc external loop supply, HART multiplex unit, Passive 4-20 mA transmitters in an engineered Safety Manager configuration.

The commissioning workflow covers installed-hardware matching, controlled start-up and functional verification for this sixteen-channel safe hart input fta.

Important Notice: Confirm the complete FC-TSHART-1620M marking, installed-system configuration, field connections and controlled functional test before commissioning or replacement.

Apter Power FC-TSHART-1620M Manuals and Guides
Apter Power FC-TSHART-1620M Product Technical Reference PDFHoneywell FC-TSHART-1620M Official Manual PDF
The first document is an Apter Power model-specific technical reference. The second supports model-specific installation, configuration and engineering verification.
Safety pressure transmittersTerminates safety-related analog input loops
HART fire-and-gas loopsProvides HART multiplex access
SIL analog measurementInterfaces passive transmitters to SAI-1620m
Safe transmitter diagnosticsOrganizes field loops around documented common references
Read the applicable Honeywell installation instructions before work. Verify FC-TSHART-1620M and the installed Safety Manager configuration.
1Verify the complete FC-TSHART-1620M marking and the assigned Safety Manager position before field work.
2Isolate the applicable power, network and field energy before disconnecting FC-TSHART-1620M.
3Use ESD controls and protect the keyed connectors of FC-TSHART-1620M during handling.
4Record the installed wiring, jumpers, node or channel assignment before replacement.
5Confirm SAI-1620m safe analog input module and 30 Vdc external loop supply against the approved system configuration.
6Restore FC-TSHART-1620M under controlled conditions and review the product-specific diagnostics.
7Complete a functional test for safety pressure transmitters before production release.

Technical notes

Technical notes

Keep the documented channel commons separated, verify the loop supply and confirm both analog accuracy and HART communication.

FAQS

  • How can the FC-TSHART-1620M Sixteen-Channel Safe HART Input FTA be function-tested for HART fire-and-gas loops without disturbing the process?
    Use a controlled stimulus or limited command, observe the expected system indication and confirm the intended response while normal interlocks remain effective.
  • Which diagnostics should be reviewed if the FC-TSHART-1620M Sixteen-Channel Safe HART Input FTA stops performing its assigned system function?
    Check seating, the matched SAI-1620m safe analog input module, the condition of 30 Vdc external loop supply and the model-specific diagnostics before replacing more hardware.
  • Can the FC-TSHART-1620M Sixteen-Channel Safe HART Input FTA used for SIL analog measurement be transferred to another Safety Manager position without engineering review?
    No. Confirm the hardware execution, connector scheme and approved Safety Manager configuration before transferring FC-TSHART-1620M to a different duty.
  • What evidence should be retained after the FC-TSHART-1620M Sixteen-Channel Safe HART Input FTA returns to Safe transmitter diagnostics service?
    Retain the physical identification, as-left wiring or configuration, final diagnostics and controlled functional-test result for FC-TSHART-1620M.
  • Which SAI-1620m safe analog input module identity must be verified before fitting the FC-TSHART-1620M Sixteen-Channel Safe HART Input FTA?
    Match the complete FC-TSHART-1620M marking, assigned Safety Manager position and installed SAI-1620m safe analog input module before work.
  • How should 30 Vdc external loop supply be isolated before disconnecting the FC-TSHART-1620M Sixteen-Channel Safe HART Input FTA?
    Place the affected process in its approved maintenance state, isolate applicable energy and prove 30 Vdc external loop supply safe before disconnection.
  • What as-found wiring record is required for the FC-TSHART-1620M Sixteen-Channel Safe HART Input FTA in Safety pressure transmitters?
    Record terminal identity, polarity, shields, jumpers, cable tags and the as-found diagnostic state for FC-TSHART-1620M.
  • Which Safety Manager configuration must be checked when commissioning the FC-TSHART-1620M Sixteen-Channel Safe HART Input FTA?
    Verify the assigned channel, slot, node or interface and compare it with the approved Safety Manager configuration before enabling FC-TSHART-1620M.
Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, modules and cards, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer`s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Product Browsing History

We’re Here When You Need Us

From product insights to customer service needs, our experienced service team will focus on getting you what you need quickly

Enquire

Complete our online form.

Call Us

Speak to one of our team.