8C-PAON01

Series 8 Non-HART Analog Output Module
In Stock
Ships by Tuesday, September 22
Fast Shipping Available

Product Describe:

Honeywell 8C-PAON01 is a Series 8 Non-HART Analog Output Module. It converts controller commands into current-loop outputs for matched field termination hardware.

Ask our team:

Get a quick price for: 8C-PAON01
Quantity*
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy.

Technical specifications for 8C-PAON01

Technical specifications for 8C-PAON01

  • Manufacturer:
    Honeywell
  • Product Category:
    DCS System
  • Spare Part Number:
    51454357-175
  • Estimated shipping dimensions:
    4.4x15.2x14.3cm
  • Weight:
    0.32 kg
  • Tariff Code:
    8537101190
  • Counliy of origin:
    USA
  • Output channels:
    16
  • Output function:
    Analog output
  • Communication:
    Non-HART
  • Connector:
    DB37

Information

Information

Overview Manuals Common Applications Product Precautions
Honeywell 8C-PAON01 is a 16-channel Series 8 non-HART analog output module. It converts controller commands into current-loop outputs for matched field termination hardware.
  • Generates analog control commands
  • Interfaces non-HART final elements
  • Pairs with a Series 8 output IOTA
  • Supports redundant I/O arrangements

8C-PAON01 installs with Series 8 analog-output IOTA, C300 controller, DB37 field interface, Analog final elements in an engineered Experion Series 8 I/O configuration.

The commissioning workflow covers installed-hardware matching, controlled start-up and functional verification for this series 8 non-hart analog output module.

Important Notice: Confirm the complete 8C-PAON01 marking, installed-system configuration, field connections and controlled functional test before commissioning or replacement.

Apter Power 8C-PAON01 Manuals and Guides
Apter Power 8C-PAON01 Product Technical Reference PDFApter Power 8C-PAON01 Installation and Verification PDF
The first document is an Apter Power model-specific technical reference. The second supports model-specific installation, configuration and engineering verification.
Control-valve positioningGenerates analog control commands
Variable-speed drive referencesInterfaces non-HART final elements
Damper command loopsPairs with a Series 8 output IOTA
Process dosing outputsSupports redundant I/O arrangements
Read the applicable Honeywell installation instructions before work. Verify 8C-PAON01 and the installed Experion Series 8 I/O configuration.
1Verify the complete 8C-PAON01 marking and the assigned Experion Series 8 I/O position before field work.
2Isolate the applicable power, network and field energy before disconnecting 8C-PAON01.
3Use ESD controls and protect the keyed connectors of 8C-PAON01 during handling.
4Record the installed wiring, jumpers, node or channel assignment before replacement.
5Confirm Series 8 analog-output IOTA and C300 controller against the approved system configuration.
6Restore 8C-PAON01 under controlled conditions and review the product-specific diagnostics.
7Complete a functional test for control-valve positioning before production release.

Technical notes

Technical notes

Place final elements in a controlled state, confirm the matched IOTA and output-loop polarity, then stroke each loop at a limited command value.

FAQS

  • What evidence should be retained after the 8C-PAON01 Series 8 Non-HART Analog Output Module returns to Process dosing outputs service?
    Retain the physical identification, as-left wiring or configuration, final diagnostics and controlled functional-test result for 8C-PAON01.
  • Which Series 8 analog-output IOTA identity must be verified before fitting the 8C-PAON01 Series 8 Non-HART Analog Output Module?
    Match the complete 8C-PAON01 marking, assigned Experion Series 8 I/O position and installed Series 8 analog-output IOTA before work.
  • How should C300 controller be isolated before disconnecting the 8C-PAON01 Series 8 Non-HART Analog Output Module?
    Place the affected process in its approved maintenance state, isolate applicable energy and prove C300 controller safe before disconnection.
  • What as-found wiring record is required for the 8C-PAON01 Series 8 Non-HART Analog Output Module in Control-valve positioning?
    Record terminal identity, polarity, shields, jumpers, cable tags and the as-found diagnostic state for 8C-PAON01.
  • Which Experion Series 8 I/O configuration must be checked when commissioning the 8C-PAON01 Series 8 Non-HART Analog Output Module?
    Verify the assigned channel, slot, node or interface and compare it with the approved Experion Series 8 I/O configuration before enabling 8C-PAON01.
  • How can the 8C-PAON01 Series 8 Non-HART Analog Output Module be function-tested for Variable-speed drive references without disturbing the process?
    Use a controlled stimulus or limited command, observe the expected system indication and confirm the intended response while normal interlocks remain effective.
  • Which diagnostics should be reviewed if the 8C-PAON01 Series 8 Non-HART Analog Output Module stops performing its assigned system function?
    Check seating, the matched Series 8 analog-output IOTA, the condition of C300 controller and the model-specific diagnostics before replacing more hardware.
  • Can the 8C-PAON01 Series 8 Non-HART Analog Output Module used for Damper command loops be transferred to another Experion Series 8 I/O position without engineering review?
    No. Confirm the hardware execution, connector scheme and approved Experion Series 8 I/O configuration before transferring 8C-PAON01 to a different duty.
Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, modules and cards, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer`s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

We’re Here When You Need Us

From product insights to customer service needs, our experienced service team will focus on getting you what you need quickly

Enquire

Complete our online form.

Call Us

Speak to one of our team.

Live Chat

Send us a message.