Technical specifications for 51402755-100 K4LCN-4

  • Manufacturer:
    Honeywell
  • Product Category:
    DCS Systems
  • Spare Part Number:
    51402755-100
  • Estimated shipping dimensions:
    36.7×36.5×1.9cm
  • Weight:
    0.98 kg
  • Tariff Code:
    8537101190
  • Counliy of origin:
    USA
  • Board designation:
    K4LCN
  • Circuit-board part number:
    51402755-100
  • LCN address block:
    TS1
  • TS1 coordinate:
    7A
  • Jumper removed:
    Binary 1
  • Address parity:
    Odd
  • Binary weights:
    64, 32, 16, 8, 4, 2, 1
  • Module position:
    Slot 1
  • 4-Megaword memory board:
    51201795-400

Information

Overview Manuals Common Applications Product Precautions
Honeywell 51402755-100 K4LCN-4 provides the Local Control Network interface and node-address selection used by the WDA-type History Module.
  • TS1 address block at coordinate 7A
  • Odd-parity jumper rule
  • Seven binary address weights
  • Slot 1 chassis position

Node identity is set by the removed-jumper pattern at TS1, while the associated 51201795-400 memory board completes the listed 4-Megaword hardware arrangement.

Important Notice: Preserve the TS1 pattern and parity, confirm the 51201795-400 memory-board pairing and clear the alternate address path before startup.

Honeywell 51402755-100 K4LCN-4 Manuals & Downloads
Honeywell 51402755-100 K4LCN-4 Official Technical Reference (PDF)Honeywell 51402755-100 K4LCN-4 Installation & Commissioning Guide (PDF)

The official technical reference preserves selected Honeywell source pages for exact-model identification and verified data; the separate Installation & Commissioning Guide organizes identity control, interface checks, channel testing and acceptance records.

History Module board renewal
Replaces the exact K4LCN board in a WDA-type History Module.
LCN node restoration
Recreates the assigned network identity through TS1 binary weighting.
Memory-board pairing
Checks the 4-Megaword board identity before chassis restoration.
LCN interface maintenance
Keeps one active address-selection path and a cleared alternate path.
Apply these controls specifically to Honeywell 51402755-100 K4LCN-4 before isolation, replacement, reconnection and final release.
1
Use a grounded wrist strap, work surface and ESD-safe container.
2
Confirm both 51402755-100 and K4LCN-4 before work.
3
Record every TS1 jumper and the parity position before removal.
4
Keep the total removed-jumper count, including parity, odd.
5
Remove all jumpers or set zero on the alternate address-selection board.
6
Match the associated memory board to part number 51201795-400.
7
Seat the K4LCN board fully in slot 1 without forcing the connectors.
8
Verify the restored node address and LCN communication before service.

Alternative Names

51402755 100 K4LCN 4 51402755-100K4LCN-4

Technical notes

Record the complete board identity, TS1 jumper pattern, parity jumper and installed LCN node address before removal. Recreate the binary address at coordinate 7A, clear the unused address-selection path and verify History Module communication after seating the board in slot 1.

FAQ View All FAQ

  • Which circuit-board part number identifies Honeywell 51402755-100 K4LCN-4?
    The K4LCN circuit-board part number is 51402755-100.
  • Where is the LCN address block on Honeywell 51402755-100 K4LCN-4?
    The TS1 pinning block is located at coordinate 7A.
  • What does a removed jumper mean on Honeywell 51402755-100 K4LCN-4?
    A removed TS1 jumper represents binary 1.
  • Which parity rule applies to Honeywell 51402755-100 K4LCN-4?
    The total number of removed jumpers, including the parity jumper, must be odd.
  • Which binary weights are used by Honeywell 51402755-100 K4LCN-4?
    The node-address positions use weights 64, 32, 16, 8, 4, 2 and 1.
  • Where is Honeywell 51402755-100 K4LCN-4 installed in the module chassis?
    The K4LCN board is installed in slot 1 after its node address is selected.
  • Which memory board is paired with Honeywell 51402755-100 K4LCN-4?
    The associated 4-Megaword memory board is part number 51201795-400.
  • How should the unused LCN address path be handled for Honeywell 51402755-100 K4LCN-4?
    Remove all jumpers from the unused address board or set its configuration switches to zero before commissioning.
Related reading

Related cases and sourcing guidance

View all case studies
Manufacturers

Product Browsing History

Revisit the products you recently viewed on Apter Power.
SPEAK TO OUR TEAM
Let’s find the right solution for you.
Send us the part number, quantity and delivery destination. Our team will help confirm availability and lead time.
  • Whatsapp: +86 18030235313

    Send us a message.
  • sales13@apterpower.com

    Complete our online form.
  • +86 18030235313

    Speak to our team in your native language.