10209/2/1

Sixteen-Channel 24 Vdc Digital Output Module
In Stock
Ships by Monday, September 21
Fast Shipping Available

Product Describe:

Honeywell 10209/2/1 is a Sixteen-Channel 24 Vdc Digital Output Module. It sources low-power field loads under FSC control and removes output energy on watchdog shutdown.

Ask our team:

Get a quick price for: 10209/2/1
Quantity*
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy.

Technical specifications for 10209/2/1

Technical specifications for 10209/2/1

  • Manufacturer:
    Honeywell
  • Product Category:
    DCS System
  • Spare Part Number:
    10209/2/1
  • Estimated shipping dimensions:
    2x19x12.8cm
  • Weight:
    0.12 kg
  • Tariff Code:
    8537101190
  • Counliy of origin:
    USA
  • Output channels:
    16
  • Output supply:
    24 Vdc
  • Rated output current:
    100 mA maximum
  • Load power:
    2.5 W maximum
  • Output type:
    Solid-state source
  • Short-circuit protection:
    Yes
  • Lamp load:
    50 mA; 1.2 W maximum
  • Load capacitance:
    1 uF maximum
  • Voltage drop:
    <1.2 Vdc at 100 mA
  • Off-state current:
    <0.1 mA
  • Watchdog input:
    4 mA
  • Module size:
    4 TE; 3 HE
  • 5 Vdc current:
    35 mA
  • 24 Vdc current:
    85 mA without load
  • Key coding:
    A9; C21

Information

Information

Overview Manuals Common Applications Product Precautions
Honeywell 10209/2/1 is a 16-channel 24 Vdc digital-output module for the Fail Safe Controller. It sources low-power field loads under FSC control and removes output energy on watchdog shutdown.
  • Switches sixteen low-power 24 Vdc loads
  • Sources field current from solid-state outputs
  • De-energizes outputs through the watchdog on shutdown
  • Protects output channels against short circuits

10209/2/1 installs with FSC I/O rack, 24 Vdc field supply, A9/C21 keyed position, Protected resistive or inductive load in an engineered Fail Safe Controller configuration.

The commissioning workflow covers installed-hardware matching, controlled start-up and functional verification for this sixteen-channel 24 vdc digital output module.

Important Notice: Confirm the complete 10209/2/1 marking, installed-system configuration, field connections and controlled functional test before commissioning or replacement.

Apter Power 10209/2/1 Manuals and Guides
Apter Power 10209/2/1 Product Technical Reference PDFApter Power 10209/2/1 Installation and Verification PDF
The first document is an Apter Power model-specific technical reference. The second supports model-specific installation, configuration and engineering verification.
Low-power trip indicationSwitches sixteen low-power 24 Vdc loads
Safety relay pilot commandsSources field current from solid-state outputs
FSC annunciator outputsDe-energizes outputs through the watchdog on shutdown
Shutdown-sequence signalingProtects output channels against short circuits
Read the applicable Honeywell installation instructions before work. Verify 10209/2/1 and the installed Fail Safe Controller configuration.
1Verify the complete 10209/2/1 marking and its assigned Fail Safe Controller position before work.
2Isolate the energy associated with FSC I/O rack before disconnecting 10209/2/1.
3Protect the 10209/2/1 connectors and electronic assembly using approved ESD controls.
4Record the as-found 24 Vdc field supply connections and configured assignment before replacement.
5Confirm A9/C21 keyed position matches the approved installation record for 10209/2/1.
6Restore 10209/2/1 under controlled conditions and review its model-specific diagnostics.
7Complete a documented functional test for low-power trip indication before release.

Technical notes

Technical notes

Check A9/C21 keying and the external load against the channel limit, confirm suppression for inductive circuits and prove watchdog de-energization during the safety test.

FAQS

  • Which technical value is especially important during 10209/2/1 commissioning?
    Verify 24 Vdc current is 85 mA without load and use the named manufacturer procedure for the controlled functional test.
  • What should be checked if 10209/2/1 does not support safety relay pilot commands after installation?
    Check seating, 24 Vdc field supply, A9/C21 keyed position, field energy and the model-specific diagnostics before replacing additional hardware.
  • What evidence should be retained after 10209/2/1 returns to service?
    Retain the full model identity, as-left connections, configuration, diagnostic result and the final controlled test record for low-power trip indication.
  • How is 10209/2/1 identified before installation in a Fail Safe Controller cabinet?
    Match the full 10209/2/1 marking and part number 10209/2/1 to the assigned position and installed FSC I/O rack.
  • Which companion hardware must be checked when replacing 10209/2/1?
    Verify FSC I/O rack, 24 Vdc field supply and A9/C21 keyed position against the approved cabinet and project record before fitting the Sixteen-Channel 24 Vdc Digital Output Module.
  • What wiring information should be recorded before removing 10209/2/1?
    Record terminal identifiers, polarity or phase, shields, cable tags and the as-found channel or port assignment for 10209/2/1.
  • How should engineers validate 10209/2/1 after configuration?
    Restore the documented Fail Safe Controller assignment, review diagnostics and run a controlled test of its role: switches sixteen low-power 24 vdc loads.
  • Can 10209/2/1 be moved to a different slot or duty without review?
    No. Confirm keying, companion hardware and the approved configuration before assigning 10209/2/1 to another position or function.
Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, modules and cards, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer`s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

We’re Here When You Need Us

From product insights to customer service needs, our experienced service team will focus on getting you what you need quickly

Enquire

Complete our online form.

Call Us

Speak to one of our team.

Live Chat

Send us a message.