Get Parts Quote
Name
Company *
Phone *
Email *
Address
City
State / Province / Region
Zipcode
Country
Quantity *
Part Number *
Manufacturer
Preferred Condition
Additional Information
Cancel

EH-PT4

Four-Channel RTD Input Module
In Stock
Ships by Tuesday, September 22
Fast Shipping Available

Product Describe:

Hitachi EH-PT4 is a four-channel resistance-temperature-detector input module for EH-150 controllers. It converts Pt100 or Pt1000 sensor resistance into temperature values for PLC monitoring and control.

Ask our team:

Get a quick price for: EH-PT4
Quantity*
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy.

Technical specifications for EH-PT4

Technical specifications for EH-PT4

  • Manufacturer:
    Hitachi
  • Product Category:
    PLC Systems
  • Spare Part Number:
    EH-PT4
  • Estimated shipping dimensions:
    2.5x10.2x10.2cm
  • Weight:
    0.18 kg
  • Tariff Code:
    8537101190
  • Counliy of origin:
    Japan
  • Input type:
    Pt100 / Pt1000 RTD
  • Input channels:
    4
  • Conversion resolution:
    Signed 15 bit
  • Pt100 range 1:
    -20 to +40 degC
  • Pt100 range 2:
    -50 to +400 degC
  • Pt1000 range:
    -50 to +400 degC
  • Conversion time:
    Approximately 0.5 s per 4 inputs
  • Pt100 accuracy at 25 degC:
    +/-0.1 degC or +/-0.6 degC by range
  • Pt1000 accuracy at 25 degC:
    +/-0.8 degC
  • Isolation:
    Input-to-internal photocoupler isolation
  • Inter-channel isolation:
    None
  • Terminal block:
    Removable M3
  • Recommended wiring:
    3-core shielded cable
  • Maximum lead resistance:
    2 Ohm current terminal to ground
  • Internal current:
    160 mA approximately at 5 V DC
  • External supply:
    24 V DC +/-10%, 70 mA maximum

Information

Information

Overview Manuals Common Applications Product Precautions
Hitachi EH-PT4 is a four-channel resistance-temperature-detector input module for EH-150 controllers. It converts Pt100 or Pt1000 sensor resistance into temperature values for PLC monitoring and control.
  • Measures four platinum resistance-temperature detector channels
  • Linearizes Pt100 or Pt1000 resistance into signed temperature data
  • Transfers temperature values through the EH-150 I/O backplane
  • Supports open-circuit and wiring verification at the removable terminal block

EH-PT4 installs with EH-150 base and CPU, Pt100 or Pt1000 sensors, 24 V DC field supply, three-core shielded field cables in an engineered Hitachi EH-150 programmable controller configuration.

The commissioning workflow covers installed-hardware matching, controlled start-up and functional verification for this four-channel rtd input module.

Important Notice: Confirm the complete EH-PT4 marking, installed-system configuration, field connections and controlled functional test before commissioning or replacement.

Apter Power EH-PT4 Manuals and Guides
Apter Power EH-PT4 Product Technical Reference PDFHitachi EH-PT4 Official Manual PDF
The first document is an Apter Power model-specific technical reference. The second supports model-specific installation, configuration and engineering verification.
Process-vessel temperature measurementMeasures four platinum resistance-temperature detector channels
Machine bearing temperature monitoringLinearizes Pt100 or Pt1000 resistance into signed temperature data
Oven and dryer thermal controlTransfers temperature values through the EH-150 I/O backplane
Utility skid multi-point RTD acquisitionSupports open-circuit and wiring verification at the removable terminal block
Read the applicable Hitachi installation instructions before work. Verify EH-PT4 and the installed Hitachi EH-150 programmable controller configuration.
1Confirm EH-PT4 and the assigned EH-150 base position before work.
2Isolate the external 24 V DC supply and associated process interlocks.
3Keep all three RTD conductors together in a shielded cable.
4Do not introduce inter-channel potential because the four inputs are not mutually isolated.
5Short unused terminals in the arrangement specified by the Hitachi guide.
6Check lead resistance and terminal tightness before module insertion.
7Simulate at least two resistance points on every commissioned channel.
8Verify engineering units, alarm thresholds, and open-circuit diagnostics before service.

Technical notes

Technical notes

Select the Pt100 or Pt1000 range before commissioning, use three-wire shielded connections, short unused inputs as instructed, and verify channel scaling against a traceable resistance source.

FAQS

  • How should the field connections for EH-PT4 be recorded before replacement?
    Record terminal or connector identity, polarity, shield, cable tag, channel assignment, and the as-found diagnostic state before disconnecting EH-PT4.
  • What isolation is required before installing EH-PT4?
    Place process-vessel temperature measurement in the approved maintenance state, isolate every applicable power, signal, and stored-energy source, and prove the work area safe.
  • Which configuration check is essential when commissioning EH-PT4?
    Restore only the approved model-specific channel, range, address, scale, or interface settings and compare them with the physical installation before enabling the process function.
  • How can an engineer function-test EH-PT4 after installation?
    Apply a controlled input, reference, or limited output appropriate to four-channel rtd input module, observe the system indication and diagnostics, and confirm the intended process response.
  • What should be checked if EH-PT4 reports an unstable or incorrect value?
    Check seating, supply, grounding, shielding, matched components, mechanical installation, and the signal path before changing configuration or replacing additional hardware.
  • Can EH-PT4 be replaced by a visually similar model without review?
    No. Verify the complete part number, electrical execution, connector arrangement, companion hardware, and approved software or rack configuration.
  • What commissioning evidence should be retained for EH-PT4?
    Retain the full EH-PT4 identity, as-left wiring and settings, measured functional-test results, final diagnostics, and authorization to return the affected equipment to service.
  • Which installed hardware must be matched before fitting EH-PT4?
    Match the complete EH-PT4 marking to EH-150 base and CPU and Pt100 or Pt1000 sensors, then confirm the assigned Hitachi EH-150 programmable controller position and approved system configuration.
Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, modules and cards, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer`s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Product Browsing History

We’re Here When You Need Us

From product insights to customer service needs, our experienced service team will focus on getting you what you need quickly

Enquire

Complete our online form.

Call Us

Speak to one of our team.

Live Chat

Send us a message.