Speak to a sourcing specialist
sales13@apterpower.com
Get a quick price for EH-PT4
E-mail *
Mobile *
Company
Content *
Quantity *
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy

What happens after you enquire

  • 1

    Requirement review

    We review the part number, quantity and delivery requirements and ask for any missing details.
  • 2

    Quotation and availability

    We confirm the proposed item, condition, availability, price and estimated lead time in the quotation.
  • 3

    Order confirmation and dispatch

    Once the quotation and purchasing details are agreed, your contact will coordinate the order and available dispatch information.

Technical specifications for EH-PT4

  • Manufacturer:
    Hitachi
  • Product Category:
    PLC Systems
  • Spare Part Number:
    EH-PT4
  • Estimated shipping dimensions:
    2.5x10.2x10.2cm
  • Weight:
    0.18 kg
  • Tariff Code:
    8537101190
  • Counliy of origin:
    Japan
  • Input type:
    Pt100 / Pt1000 RTD
  • Input channels:
    4
  • Conversion resolution:
    Signed 15 bit
  • Pt100 range 1:
    -20 to +40 degC
  • Pt100 range 2:
    -50 to +400 degC
  • Pt1000 range:
    -50 to +400 degC
  • Conversion time:
    Approximately 0.5 s per 4 inputs
  • Pt100 accuracy at 25 degC:
    +/-0.1 degC or +/-0.6 degC by range
  • Pt1000 accuracy at 25 degC:
    +/-0.8 degC
  • Isolation:
    Input-to-internal photocoupler isolation
  • Inter-channel isolation:
    None
  • Terminal block:
    Removable M3
  • Recommended wiring:
    3-core shielded cable
  • Maximum lead resistance:
    2 Ohm current terminal to ground
  • Internal current:
    160 mA approximately at 5 V DC
  • External supply:
    24 V DC +/-10%, 70 mA maximum

Information

Overview Manuals Common Applications Product Precautions
Hitachi EH-PT4 is a four-channel resistance-temperature-detector input module for EH-150 controllers. It converts Pt100 or Pt1000 sensor resistance into temperature values for PLC monitoring and control.
  • Measures four platinum resistance-temperature detector channels
  • Linearizes Pt100 or Pt1000 resistance into signed temperature data
  • Transfers temperature values through the EH-150 I/O backplane
  • Supports open-circuit and wiring verification at the removable terminal block

EH-PT4 installs with EH-150 base and CPU, Pt100 or Pt1000 sensors, 24 V DC field supply, three-core shielded field cables in an engineered Hitachi EH-150 programmable controller configuration.

The commissioning workflow covers installed-hardware matching, controlled start-up and functional verification for this four-channel rtd input module.

Important Notice: Confirm the complete EH-PT4 marking, installed-system configuration, field connections and controlled functional test before commissioning or replacement.

Apter Power EH-PT4 Manuals and Guides
Apter Power EH-PT4 Product Technical Reference PDFHitachi EH-PT4 Official Manual PDF
The first document is an Apter Power model-specific technical reference. The second supports model-specific installation, configuration and engineering verification.
Process-vessel temperature measurementMeasures four platinum resistance-temperature detector channels
Machine bearing temperature monitoringLinearizes Pt100 or Pt1000 resistance into signed temperature data
Oven and dryer thermal controlTransfers temperature values through the EH-150 I/O backplane
Utility skid multi-point RTD acquisitionSupports open-circuit and wiring verification at the removable terminal block
Read the applicable Hitachi installation instructions before work. Verify EH-PT4 and the installed Hitachi EH-150 programmable controller configuration.
1Confirm EH-PT4 and the assigned EH-150 base position before work.
2Isolate the external 24 V DC supply and associated process interlocks.
3Keep all three RTD conductors together in a shielded cable.
4Do not introduce inter-channel potential because the four inputs are not mutually isolated.
5Short unused terminals in the arrangement specified by the Hitachi guide.
6Check lead resistance and terminal tightness before module insertion.
7Simulate at least two resistance points on every commissioned channel.
8Verify engineering units, alarm thresholds, and open-circuit diagnostics before service.

Technical notes

Select the Pt100 or Pt1000 range before commissioning, use three-wire shielded connections, short unused inputs as instructed, and verify channel scaling against a traceable resistance source.

FAQ View All FAQ

  • How should the field connections for EH-PT4 be recorded before replacement?
    Record terminal or connector identity, polarity, shield, cable tag, channel assignment, and the as-found diagnostic state before disconnecting EH-PT4.
  • What isolation is required before installing EH-PT4?
    Place process-vessel temperature measurement in the approved maintenance state, isolate every applicable power, signal, and stored-energy source, and prove the work area safe.
  • Which configuration check is essential when commissioning EH-PT4?
    Restore only the approved model-specific channel, range, address, scale, or interface settings and compare them with the physical installation before enabling the process function.
  • How can an engineer function-test EH-PT4 after installation?
    Apply a controlled input, reference, or limited output appropriate to four-channel rtd input module, observe the system indication and diagnostics, and confirm the intended process response.
  • What should be checked if EH-PT4 reports an unstable or incorrect value?
    Check seating, supply, grounding, shielding, matched components, mechanical installation, and the signal path before changing configuration or replacing additional hardware.
  • Can EH-PT4 be replaced by a visually similar model without review?
    No. Verify the complete part number, electrical execution, connector arrangement, companion hardware, and approved software or rack configuration.
  • What commissioning evidence should be retained for EH-PT4?
    Retain the full EH-PT4 identity, as-left wiring and settings, measured functional-test results, final diagnostics, and authorization to return the affected equipment to service.
  • Which installed hardware must be matched before fitting EH-PT4?
    Match the complete EH-PT4 marking to EH-150 base and CPU and Pt100 or Pt1000 sensors, then confirm the assigned Hitachi EH-150 programmable controller position and approved system configuration.
Manufacturers

Product Browsing History

Revisit the products you recently viewed on Apter Power.
SPEAK TO OUR TEAM
Let’s find the right solution for you.
Send us the part number, quantity and delivery destination. Our team will help confirm availability and lead time.
  • Whatsapp: +86 18030235313

    Send us a message.
  • sales13@apterpower.com

    Complete our online form.
  • +86 18030235313

    Speak to our team in your native language.