The F60CPU03 is the central module of the HIMatrix F60 safety-related controller. This module can only be inserted in the slot next to the power supply module of the F60 subrack, and is used to store the operating system and user program, execute all central functions, and communicate with the PADT and other systems.
High-Speed Response
Large Capacity Memory
SOE Supported
F60CPU03 features fast response time, large memory capacity, comprehensive safety monitoring and rich communication interfaces. It meets SIL 3 and PL e safety certifications, supports SOE function, multitasking and reload, and is suitable for high-performance safety-critical applications.
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description.
HIMA F60CPU03 Safety-Related Controller Module Manuals, Datasheets, Drivers, Link
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description.
Oil & Gas
Used for emergency shutdown, fire and gas detection, and pipeline interlock systems in offshore platforms, refineries and pumping stations. It complies with SIL 3 safety standards and operates reliably in explosive hazardous areas.
Petrochemical
Applied in reactor control, furnace safety and high-pressure process interlocks for chemical synthesis and polymer production plants. It ensures safe operation under high temperature, high pressure and corrosive environments.
Power Generation
Deployed in boiler protection, turbine trip and burner management systems of thermal power plants. It meets strict EMC requirements and maintains stable performance in complex electromagnetic environments.
Railway
Suitable for signal control, level crossing protection and rolling stock safety systems in rail transit. It meets EN 50126/50128/50129 standards and supports SIL 4 safety applications.
Pharmaceutical
Used in sterile production, bioreactor and pressure-temperature safety interlock systems. It meets GMP site requirements while maintaining SIL 3 safety integrity.
Metal & Mining
Installed in smelting, blast furnace and ore processing for emergency stop and gas monitoring. It withstands dust, vibration and wide temperature variations in industrial sites.
This module must only be installed in the designated slot of the HIMatrix F60 subrack and must be used with the SILworX programming tool for configuration and commissioning. All installation and maintenance work must be carried out by qualified personnel with ESD protective measures, and the module must only be operated within the specified environmental and voltage ranges to maintain safety integrity and communication stability. When performing a reset operation, all fieldbus connectors must be disconnected before power‑on to avoid communication interference, and any module replacement must be performed with the power completely removed using only identical or HIMA‑approved spare parts to ensure system safety and compliance.
What is the function of F60CPU03 in the HIMatrix system?
F60CPU03 is the central module of the HIMatrix F60 safety-related controller, used to store the operating system and user program, execute all central functions, and communicate with the PADT and other systems. It also monitors the operating voltage and operating temperature of the system.
What safety certifications does F60CPU03 have?
F60CPU03 is certified by TÜV up to SIL 3 (IEC 61508, IEC 61511, IEC 62061) and PL e (EN ISO 13849-1), complying with multiple international safety standards for safety-critical applications.
What communication interfaces does F60CPU03 provide?
F60CPU03 provides 4× Ethernet RJ45 ports (10/100Base-T) and 2× 9-pole D-Sub fieldbus interfaces, supporting safeethernet, Modbus TCP, PROFINET, TCP SR, SNTP and other communication protocols.
What programming tool is used for F60CPU03?
F60CPU03 is exclusively configured and programmed using the SILworX software tool, which is used to create user programs, set parameters, and perform diagnostic monitoring of the module.
How is F60CPU03 installed in the F60 subrack?
F60CPU03 can only be installed in slot 2 of the F60 subrack, adjacent to the PS 01 power supply module. It must be inserted into the backplane and secured with screws at the upper and lower ends of the front plate.
Manufacturers
Supporting new and legacy automation
Whether you're maintaining existing equipment or sourcing parts for current systems, we provide fast, dependable supply you can rely on.
Please try to be as accurate as possible with your search.
We can quote you on 1000s of specialist parts, even if they are not listed on our website.