Speak to a sourcing specialist
sales13@apterpower.com
Get a quick price for F2 DO 16 02
E-mail *
Mobile *
Company
Content *
Quantity *
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy

What happens after you enquire

  • 1

    Requirement review

    We review the part number, quantity and delivery requirements and ask for any missing details.
  • 2

    Quotation and availability

    We confirm the proposed item, condition, availability, price and estimated lead time in the quotation.
  • 3

    Order confirmation and dispatch

    Once the quotation and purchasing details are agreed, your contact will coordinate the order and available dispatch information.

Technical specifications for F2 DO 16 02

  • Manufacturer:
    HIMA
  • Product Category:
    DCS Systems
  • Spare Part Number:
    F2 DO 16 02
  • Estimated shipping dimensions:
    20.5x11.2x6.5cm
  • Weight:
    0.8 kg
  • Tariff Code:
    8537101190
  • Counliy of origin:
    Germany
  • Product family:
    HIMatrix F
  • Device form:
    Remote output I/O
  • Digital inputs:
    None listed
  • Digital outputs:
    16
  • Output technology:
    Relay
  • Contact potential:
    Up to 60 V
  • Ethernet switch ports:
    2
  • Line monitoring:
    Not listed
  • System engineering:
    SILworX
  • Safety networking:
    SafeEthernet portfolio

Information

Overview Manuals Common Applications Product Precautions
The F2 DO 16 02 concentrates sixteen relay outputs in a networked HIMatrix remote-I/O format for controlled safety-system output duties.
  • Confirm all sixteen relay-output assignments before conductor transfer.
  • Keep the installed contact potential within the documented 60 V limit.
  • Retain both Ethernet switch-port connections and network records.
  • Do not borrow ratings from F2 DO 16 01 or another F2 output suffix.

This remote output module connects relay-actuated field circuits to a HIMatrix network. Output loads, protective devices and network topology remain defined by the approved installation.

Important Notice: Verify F2 DO 16 02 rather than F2 DO 16 01; the output technology and limits are suffix-specific.

HIMA F2 DO 16 02 Manuals & Downloads
HIMA F2 DO 16 02 Technical Reference (PDF)HIMA F2 DO 16 02 Installation & Commissioning Guide (PDF)

The technical reference consolidates exact product data and evidence boundaries. The installation guide organizes controlled replacement, wiring or network checks, commissioning and acceptance.

Remote trip outputs
Operate approved field circuits from a distributed safety station.
Relay-isolated duties
Apply relay outputs where the documented field interface requires contacts.
Distributed shutdown logic
Place sixteen controlled outputs near the protected equipment.
Networked cabinet expansion
Extend output capacity through the validated HIMatrix Ethernet layout.
HIMA F2 DO 16 02 installation checks: preserve the exact model identity, documented system arrangement and controlled acceptance evidence.
1
Verify the complete manufacturer and model marking against the approved bill of materials.
2
Record the installed position, terminal arrangement, network assignment and visible diagnostics before removal.
3
De-energize the affected circuit and apply the site isolation and electrostatic-control procedure.
4
Compare every conductor, connector and address with the controlled drawing before transfer.
5
Inspect mating parts, grounding, shielding and enclosure condition before installing the replacement.
6
Restore only the validated project and the documented channel or communication settings.
7
Review startup diagnostics before any live functional test is attempted.
8
Prove the intended response and retain the witnessed acceptance record before release.

Technical notes

Document the load, protective device and contact-potential requirement for each of the sixteen relay outputs before commissioning.

FAQ View All FAQ

  • What is HIMA F2 DO 16 02?
    HIMA F2 DO 16 02 is a HIMatrix remote output module with sixteen digital relay outputs.
  • How many outputs are provided by HIMA F2 DO 16 02?
    The exact model provides sixteen digital outputs and does not list digital input channels.
  • What output technology does HIMA F2 DO 16 02 use?
    Its sixteen outputs use relay contacts.
  • What contact potential is documented for HIMA F2 DO 16 02?
    HIMA lists relay contact potential up to 60 V for this model.
  • How many Ethernet switch ports does HIMA F2 DO 16 02 have?
    The manufacturer portfolio lists two Ethernet switch ports.
  • Is line monitoring listed for HIMA F2 DO 16 02?
    No line-monitoring feature is listed for this exact execution in the cited manufacturer table.
  • What load information must be checked before installing HIMA F2 DO 16 02?
    Check each connected load, contact voltage, protective device and controlled output assignment against the approved drawings.
  • What completes commissioning of HIMA F2 DO 16 02?
    Review network and module diagnostics, then witness every required relay-output response under the controlled test procedure.
Manufacturers

Product Browsing History

Revisit the products you recently viewed on Apter Power.
SPEAK TO OUR TEAM
Let’s find the right solution for you.
Send us the part number, quantity and delivery destination. Our team will help confirm availability and lead time.
  • Whatsapp: +86 18030235313

    Send us a message.
  • sales13@apterpower.com

    Complete our online form.
  • +86 18030235313

    Speak to our team in your native language.