Technical specifications for IC697MDL340

  • Manufacturer:
    General Electric
  • Product Category:
    PLC Systems
  • Estimated shipping dimensions:
    4x21.8x29.3cm
  • Weight:
    0.62 kg
  • Tariff Code:
    8537101190
  • Counliy of origin:
    USA
  • Product family:
    Series 90-70
  • Output type:
    120 VAC discrete output
  • Output count:
    16 points
  • Grouping:
    4 isolated groups of 4
  • Point capacity:
    2 A steady-state
  • Group capacity:
    4 A maximum
  • Group fuse:
    10 A slow-acting
  • Status indication:
    Point LEDs and FUSE LED

Information

Overview Manuals Common Applications Product Precautions
GE IC697MDL340 organizes sixteen source-controlled AC outputs so separate groups can operate from different phases of a 120 VAC system. Point LEDs, an open-fuse indication and the removable terminal board support commissioning and maintenance without changing the configured I/O references.
  • 16 output points arranged as four groups of four
  • 120 VAC, 2 A point rating
  • 10 A slow-acting fuse for each group
  • High-inrush capability for inductive and incandescent loads

The engineered signal path is Series 90-70 backplane command → IC697MDL340 logic and isolation → Four fused AC output groups → Contactors, solenoids or indicator loads. Commission each boundary against the controlled project record.

Important Notice: De-energize the rack and every field supply before removing the module or terminal board.

GE IC697MDL340 Manuals & Downloads
GE IC697MDL340 Technical Reference (PDF)GE IC697MDL340 Installation & Commissioning Guide (PDF)

The Technical Reference is a model-specific official GE manual excerpt. The separate Installation & Commissioning Guide organizes field preparation, verification and acceptance for GE IC697MDL340.

Contactor control
Handles the inrush profile of many industrial contactor coils.
Solenoid actuation
Switches grouped 120 VAC solenoid circuits within point and group limits.
Indicator lighting
Drives incandescent or other AC indication loads with duty-cycle review.
Multi-phase grouped outputs
Lets isolated groups use different phases when wiring follows the module diagram.
Apply these controls specifically to GE IC697MDL340 before isolation, replacement, reconnection, energization and final release.
1
De-energize the rack and every field supply before removing the module or terminal board.
2
Keep each four-point group at or below the documented 4 A combined load.
3
Use only the specified 10 A slow-acting replacement fuse for a group circuit.
4
Account for load inrush and repetition rate rather than sizing only from steady-state current.
5
Maintain separation between group hot and neutral conductors when different phases are used.
6
Verify the mechanical key before inserting a replacement IC697MDL340.
7
Support the terminal-board wire bundle so it does not pull on the hinged door or connector.
8
After commissioning, prove every point LED, the FUSE indication and the commanded safe state for a controller fault.

Technical notes

GE IC697MDL340 provides sixteen 120 VAC output points in four isolated and individually fused groups for Series 90-70 field loads.

FAQ View All FAQ

  • How are the outputs grouped on GE IC697MDL340?
    The sixteen points are divided into four isolated groups of four outputs.
  • What is the steady-state point rating of GE IC697MDL340?
    Each output point is rated for 2 A at 120 VAC, subject to the group and thermal limits.
  • What is the combined current limit for one GE IC697MDL340 group?
    The four outputs in a group are limited to 4 A total.
  • Which fuse protects each GE IC697MDL340 group?
    Each group uses a 10 A slow-acting fuse; the manual identifies Bussmann MDA-10 or Littelfuse 326010.
  • Can GE IC697MDL340 switch inductive loads?
    Yes. Its high-inrush design supports solenoids, relays and many contactors when the duty cycle remains within the published limits.
  • What does the GE IC697MDL340 FUSE LED indicate?
    It illuminates when the open-fuse detector senses a failed internal group fuse.
  • How is GE IC697MDL340 configured?
    The I/O references and fault response are assigned in the Series 90-70 programming software; the module has no configuration DIP switches.
  • What should be tested after replacing GE IC697MDL340?
    Exercise all sixteen commands, verify load voltage, confirm group current, check the point LEDs and simulate the selected fault-state behavior.
Manufacturers

Product Browsing History

Revisit the products you recently viewed on Apter Power.
SPEAK TO OUR TEAM
Let’s find the right solution for you.
Send us the part number, quantity and delivery destination. Our team will help confirm availability and lead time.
  • Whatsapp: +86 18030235313

    Send us a message.
  • sales13@apterpower.com

    Complete our online form.
  • +86 18030235313

    Speak to our team in your native language.