Speak to a sourcing specialist
sales13@apterpower.com

IC693CPU374

Ethernet Programmable Controller CPU Module
Product image is representative; revision or series may vary. Contact us to request a specific version.

Product Describe:

GE IC693CPU374 combines Series 90-30 program execution with an embedded Ethernet interface. The CPU374 PLUS implementation supports controller programming, Ethernet Global Data and client/server communication within a configured control network.
  • Manufacturer part number
    IC693CPU374
  • Shipping
    Swift global dispatch
  • Condition
    New, original product
  • Shipping size (est.)
    3.5cm x 13.2cm x 13.5cm
  • Country of Origin
    USA
Get a quick price for IC693CPU374
E-mail *
Mobile
Company
Content *
Quantity *
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy

What happens after you enquire

  • 0

    Review your reference

    Send the complete IC693CPU374 reference, hardware/firmware details and the retained application configuration.

  • 1

    Confirm the offer

    Review the offered revision against rack power, companion I/O versions and required Ethernet services.

  • 2

    Arrange dispatch

    Confirm quantity, delivery details and the agreed dispatch date before shipment arrangement.

  • Match the complete marking

    Provide the complete IC693CPU374 marking, hardware revision, CPU and Ethernet firmware, and installed rack configuration.

  • Check the offered item before ordering

    Request label and connector photographs. Have your maintenance team compare the offered IC693CPU374 with the installed CPU, project configuration and applicable GE Series 90-30 instructions.

Technical specifications for IC693CPU374

  • Manufacturer:
    General Electric
  • Product Category:
    PLC Systems
  • Spare Part Number:
    IC693CPU374
  • Weight:
    0.4 kg
  • Tariff Code:
    8537101190
  • Controller architecture:
    Single-slot CPU with embedded Ethernet
  • Processor:
    AMD SC520; 133 MHz
  • Boolean instruction time:
    0.15 µs per instruction
  • Memory technologies:
    RAM and Flash
  • Total user memory:
    240 KB (245,760 bytes)
  • Discrete inputs %I:
    2,048 points; fixed
  • Discrete outputs %Q:
    2,048 points; fixed
  • Global memory %G:
    1,280 bits; fixed
  • Internal coils %M:
    4,096 bits; fixed
  • Temporary coils %T:
    256 bits; fixed
  • System status %S:
    128 bits across %S, %SA, %SB and %SC
  • Register memory %R:
    128–32,640 words; configurable
  • Analog input memory %AI:
    128–32,640 words; configurable
  • Analog output memory %AQ:
    128–32,640 words; configurable
  • System registers %SR:
    28 words; fixed
  • Timers and counters:
    More than 2,000; available-memory dependent
  • Rack power demand:
    1.48 A at +5 V DC; 7.4 W
  • Required supply type:
    High Capacity: IC693PWR330 / 331 / 332
  • Maximum baseplates:
    8 total: CPU baseplate plus 7 expansion/remote
  • Ethernet connections:
    2 × RJ45, 10/100Base-T/TX; auto-sensing
  • Ethernet IP identities:
    1 shared IP address
  • Ethernet services:
    SRTP, EGD, Modbus/TCP client/server
  • SRTP client channels:
    Up to 16
  • SRTP/TCP connections:
    Up to 36 total: 20 server plus 16 client
  • Serial access:
    SNP/SNPX through power-supply RS-485 port
  • Clock backup:
    Battery backed
  • Floating-point operations:
    Hardware supported
  • Periodic subroutine:
    Supported

Information

Overview Downloads Applications / Compatibility Product Precautions
  • GE IC693CPU374 brings control execution and network services into the same rack position. Replacement planning must therefore preserve both the PLC application and the Ethernet configuration, including the revision-dependent behavior of the CPU374 PLUS implementation.
Execution and exchange: PLC logic and Ethernet services share a configured controller installation.
Revision matching: CPU firmware, Ethernet firmware and companion I/O versions require separate checks.
Retention planning: RAM backup and Flash/program-store operations serve different recovery needs.
The CPU374 PLUS uses an embedded Ethernet switch with one network identity. Its two connectors extend an Ethernet tree; they do not form independent redundant controller interfaces. The network design must avoid a ring and preserve the correct IP address, subnet mask and gateway when hardware configuration is transferred.

User memory is allocated among application logic and configurable register and analog-reference areas. Increasing a word-memory allocation reduces the space available elsewhere. A retained project should therefore include the actual reference-memory configuration as well as logic, hardware configuration and the reference values required by the recovery procedure.

Compatibility reaches beyond the CPU itself. The documented implementation requires a high-capacity power supply and specific minimum versions of several companion modules. CPU and Ethernet firmware are separate parts of the release identity. Compare the installed combination with the offered unit before restoring communications or releasing outputs to the process.
Controller platform reference: GE Series 90-30 CPU374 PLUS. Match the installed CPU and Ethernet revisions.
Use the original CPU374 PLUS excerpt to review hardware and revision requirements, and the separate installation guide to plan a controlled replacement. View PDF supplies a communication and memory-design review for the documented implementation.
Original manufacturer pages retain their technical context. Use the Apter Power guide with the applicable manufacturer instructions and approved installation design.
System and supply context: IC693CPU374 is a Series 90-30 controller reference. The technical data presented here covers the CPU374 PLUS implementation; power supplies, expansion hardware, batteries and field modules are separate items unless itemized.

Application scope: Use it within a compatible, configured rack and Ethernet network. Hardware and CPU/Ethernet firmware must match the required application services; a two-port Ethernet connection does not establish network redundancy.
Prepare GE IC693CPU374 for its configured installation using these checks.
Freeze the complete revision identity

Record the hardware suffix and separate CPU/Ethernet firmware versions; do not assume a base catalogue number proves a KZ or PLUS revision.

Capture the recovery set

Retain logic, hardware configuration, reference data, memory allocations and network addressing before disconnection.

Check the rack power margin

Use the specified high-capacity supply and include connected modules and any powered serial converters in the load calculation.

Control the work state

Isolate the rack and field energy according to the approved procedure. Follow hazardous-location restrictions and the manufacturer battery procedure where applicable.

Preserve a tree-shaped Ethernet path

Do not connect both embedded switch ports directly or indirectly into the same network path to form a ring.

Release logic and communication together

Validate the restored application, configured I/O, Ethernet services, fault tables and process response before removing temporary inhibits.

Alternative Names

GE IC693CPU374 GE Fanuc IC693 CPU374

Technical notes

Reference-memory accounting: The 240 KB total is not an additional dedicated program allowance. Actual program space depends on configured %R, %AI and %AQ allocations.

Serial-port location: The CPU has no built-in serial connector. SNP/SNPX access uses the power-supply RS-485 port; any serial converter adds its own rack load.

Companion-module revisions: For the documented CPU374 PLUS combination, IC693MDL730 must be revision E or later and IC693ALG220/221 revision G or later. IC693PBM200 requires firmware 1.16 or later and IC693PBS201 1.28.1 or later.

Diagnostic access under load: Heavy EGD or SRTP traffic can block Station Manager operation. Loss of that diagnostic response alone does not identify a failed CPU; inspect traffic load and retained fault information.

FAQ View All FAQ

  • Why can a hardware-configuration store disconnect the programmer from IC693CPU374?
    The stored configuration can change the CPU’s IP settings or restart the Ethernet interface. The programming target address is maintained separately. Compare both address sets before reconnecting, and store hardware configuration separately from logic/reference data when the restart would interrupt a combined operation.
  • Does an empty PLC fault table on IC693CPU374 prove that its IP address is unique?
    No. The documented CPU374 implementation does not log a PLC fault merely because it detects a duplicate IP address. Check the network address assignment and the actual responding device rather than using the fault table as proof of uniqueness.
  • Why can several zero-period EGD exchanges on IC693CPU374 produce unequal update counts?
    Zero requests production as fast as scheduling permits, not equal time for every exchange. Multiple zero-period exchanges can receive uneven service. Choose appropriate nonzero production periods and compare measured update rates with the application timing requirements.
  • How should an application read an SRTP transfer larger than 256 bytes from IC693CPU374?
    Such a transfer is not guaranteed to be written atomically. Use channel-status bits or RDCS status to establish completion before consuming the whole block; otherwise the application may combine new and old portions of the data.
  • Why can repeated connect/disconnect cycles exhaust client resources on IC693CPU374?
    Closed TCP resources remain allocated during the documented linger interval. Rapid cycling can consume the available pool. Preserve an appropriate persistent channel or retask it to the same remote device, then use controlled wait/retry logic instead of continuously opening new connections.
  • Can a flash-store timeout on IC693CPU374 mean that the Ethernet interface has failed?
    Not by itself. Flash or program-store operations can temporarily suspend Ethernet data transfer. Allow the approved store to complete and inspect its result before recovery; adjust programming-software timeout only within the documented procedure.
  • Why might an SRTP channel on IC693CPU374 time out even when the remote server eventually responds?
    The application timeout includes TCP/SRTP connection establishment, maintenance and retransmission time. Compare the timeout with the complete transaction rather than only the server’s processing time. A temporary timeout does not necessarily stop the channel.
  • Should the wsnd_buf advanced parameter on IC693CPU374 be enlarged to cure a slow connection?
    No. Changing this parameter can extinguish the LAN indication and drop the connection in the documented implementation. Keep its approved value and investigate traffic scheduling, connection resources and network conditions instead.
Manufacturers

Product Browsing History

Revisit the products you recently viewed on Apter Power.
SPEAK TO OUR TEAM
Let’s find the right solution for you.
Send us the part number, quantity and delivery destination. Our team will help confirm availability and lead time.
  • Whatsapp: +86 18030235313

    Send us a message.
  • sales13@apterpower.com

    Complete our online form.
  • +86 18030235313

    Speak to our team in your native language.