Technical specifications for IC693CPU374
-
Manufacturer:General Electric
-
Product Category:PLC Systems
-
Spare Part Number:IC693CPU374
-
Weight:0.4 kg
-
Tariff Code:8537101190
-
Controller architecture:Single-slot CPU with embedded Ethernet
-
Processor:AMD SC520; 133 MHz
-
Boolean instruction time:0.15 µs per instruction
-
Memory technologies:RAM and Flash
-
Total user memory:240 KB (245,760 bytes)
-
Discrete inputs %I:2,048 points; fixed
-
Discrete outputs %Q:2,048 points; fixed
-
Global memory %G:1,280 bits; fixed
-
Internal coils %M:4,096 bits; fixed
-
Temporary coils %T:256 bits; fixed
-
System status %S:128 bits across %S, %SA, %SB and %SC
-
Register memory %R:128–32,640 words; configurable
-
Analog input memory %AI:128–32,640 words; configurable
-
Analog output memory %AQ:128–32,640 words; configurable
-
System registers %SR:28 words; fixed
-
Timers and counters:More than 2,000; available-memory dependent
-
Rack power demand:1.48 A at +5 V DC; 7.4 W
-
Required supply type:High Capacity: IC693PWR330 / 331 / 332
-
Maximum baseplates:8 total: CPU baseplate plus 7 expansion/remote
-
Ethernet connections:2 × RJ45, 10/100Base-T/TX; auto-sensing
-
Ethernet IP identities:1 shared IP address
-
Ethernet services:SRTP, EGD, Modbus/TCP client/server
-
SRTP client channels:Up to 16
-
SRTP/TCP connections:Up to 36 total: 20 server plus 16 client
-
Serial access:SNP/SNPX through power-supply RS-485 port
-
Clock backup:Battery backed
-
Floating-point operations:Hardware supported
-
Periodic subroutine:Supported
Information
- GE IC693CPU374 brings control execution and network services into the same rack position. Replacement planning must therefore preserve both the PLC application and the Ethernet configuration, including the revision-dependent behavior of the CPU374 PLUS implementation.
Revision matching: CPU firmware, Ethernet firmware and companion I/O versions require separate checks.
Retention planning: RAM backup and Flash/program-store operations serve different recovery needs.
User memory is allocated among application logic and configurable register and analog-reference areas. Increasing a word-memory allocation reduces the space available elsewhere. A retained project should therefore include the actual reference-memory configuration as well as logic, hardware configuration and the reference values required by the recovery procedure.
Compatibility reaches beyond the CPU itself. The documented implementation requires a high-capacity power supply and specific minimum versions of several companion modules. CPU and Ethernet firmware are separate parts of the release identity. Compare the installed combination with the offered unit before restoring communications or releasing outputs to the process.
IC693CPU374 Official CPU374 PLUS Technical Excerpt
Original English manufacturer ordering, ratings, compatibility and Ethernet operational information for the CPU374 PLUS implementation. PDF · 7 pages.IC693CPU374 Installation & Verification Guide
Apter Power replacement guide covering revision capture, rack loading, retained memory, configuration transfer and functional release. PDF · 5 pages.
Application scope: Use it within a compatible, configured rack and Ethernet network. Hardware and CPU/Ethernet firmware must match the required application services; a two-port Ethernet connection does not establish network redundancy.
Installed Series 90-30 control
Execute a retained PLC application with the correct rack configuration, memory allocations and field I/O versions.Ethernet data exchange
Exchange configured EGD and SRTP data with supported PLCs and host applications using the intended producer/consumer relationships.Modbus/TCP integration
Use supported client/server functions with compatible firmware and engineering software; validate function codes and destination memory.Distributed rack installations
Support the permitted CPU-plus-expansion/remote baseplate arrangement after checking power, bus hardware and the configured I/O map.
Record the hardware suffix and separate CPU/Ethernet firmware versions; do not assume a base catalogue number proves a KZ or PLUS revision.
Retain logic, hardware configuration, reference data, memory allocations and network addressing before disconnection.
Use the specified high-capacity supply and include connected modules and any powered serial converters in the load calculation.
Isolate the rack and field energy according to the approved procedure. Follow hazardous-location restrictions and the manufacturer battery procedure where applicable.
Do not connect both embedded switch ports directly or indirectly into the same network path to form a ring.
Validate the restored application, configured I/O, Ethernet services, fault tables and process response before removing temporary inhibits.
Alternative Names
Technical notes
Reference-memory accounting: The 240 KB total is not an additional dedicated program allowance. Actual program space depends on configured %R, %AI and %AQ allocations.
Serial-port location: The CPU has no built-in serial connector. SNP/SNPX access uses the power-supply RS-485 port; any serial converter adds its own rack load.
Companion-module revisions: For the documented CPU374 PLUS combination, IC693MDL730 must be revision E or later and IC693ALG220/221 revision G or later. IC693PBM200 requires firmware 1.16 or later and IC693PBS201 1.28.1 or later.
Diagnostic access under load: Heavy EGD or SRTP traffic can block Station Manager operation. Loss of that diagnostic response alone does not identify a failed CPU; inspect traffic load and retained fault information.
FAQ View All FAQ
-
Why can a hardware-configuration store disconnect the programmer from IC693CPU374?The stored configuration can change the CPU’s IP settings or restart the Ethernet interface. The programming target address is maintained separately. Compare both address sets before reconnecting, and store hardware configuration separately from logic/reference data when the restart would interrupt a combined operation.
-
Does an empty PLC fault table on IC693CPU374 prove that its IP address is unique?No. The documented CPU374 implementation does not log a PLC fault merely because it detects a duplicate IP address. Check the network address assignment and the actual responding device rather than using the fault table as proof of uniqueness.
-
Why can several zero-period EGD exchanges on IC693CPU374 produce unequal update counts?Zero requests production as fast as scheduling permits, not equal time for every exchange. Multiple zero-period exchanges can receive uneven service. Choose appropriate nonzero production periods and compare measured update rates with the application timing requirements.
-
How should an application read an SRTP transfer larger than 256 bytes from IC693CPU374?Such a transfer is not guaranteed to be written atomically. Use channel-status bits or RDCS status to establish completion before consuming the whole block; otherwise the application may combine new and old portions of the data.
-
Why can repeated connect/disconnect cycles exhaust client resources on IC693CPU374?Closed TCP resources remain allocated during the documented linger interval. Rapid cycling can consume the available pool. Preserve an appropriate persistent channel or retask it to the same remote device, then use controlled wait/retry logic instead of continuously opening new connections.
-
Can a flash-store timeout on IC693CPU374 mean that the Ethernet interface has failed?Not by itself. Flash or program-store operations can temporarily suspend Ethernet data transfer. Allow the approved store to complete and inspect its result before recovery; adjust programming-software timeout only within the documented procedure.
-
Why might an SRTP channel on IC693CPU374 time out even when the remote server eventually responds?The application timeout includes TCP/SRTP connection establishment, maintenance and retransmission time. Compare the timeout with the complete transaction rather than only the server’s processing time. A temporary timeout does not necessarily stop the channel.
-
Should the wsnd_buf advanced parameter on IC693CPU374 be enlarged to cure a slow connection?No. Changing this parameter can extinguish the LAN indication and drop the connection in the documented implementation. Keep its approved value and investigate traffic scheduling, connection resources and network conditions instead.
Supporting new and legacy automation
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-
We can't find any results for “”.
Related cases and sourcing guidance
View all case studiesYou May Also Like
Product Browsing History
-
Whatsapp: +86 18030235313
Send us a message. -
sales13@apterpower.com
Complete our online form. -
+86 18030235313
Speak to our team in your native language.