Speak to a sourcing specialist
sales13@apterpower.com

IC670GBI002

GE Fanuc Field Control Genius Bus Interface Unit, 24 VDC
In Stock
Ships by Thursday, November 12
Fast Shipping Available
Product image is representative; revision or series may vary. Contact us to request a specific version.

Product Describe:

GE IC670GBI002 is ge fanuc field control genius bus interface unit, 24 vdc. It couples a Field Control station to a Genius network and coordinates data, configuration and diagnostics for the installed I/O modules.
Get a quick price for IC670GBI002
E-mail *
Mobile *
Company
Content *
Quantity *
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy

What happens after you enquire

  • 1

    Requirement review

    We review the part number, quantity and delivery requirements and ask for any missing details.
  • 2

    Quotation and availability

    We confirm the proposed item, condition, availability, price and estimated lead time in the quotation.
  • 3

    Order confirmation and dispatch

    Once the quotation and purchasing details are agreed, your contact will coordinate the order and available dispatch information.

Technical specifications for IC670GBI002

  • Manufacturer:
    General Electric
  • Product Category:
    PLC Systems
  • Spare Part Number:
    IC670GBI002
  • Estimated shipping dimensions:
    16.2x10.9x10cm
  • Weight:
    0.68 kg
  • Tariff Code:
    8537101190
  • Counliy of origin:
    USA
  • Network:
    Genius bus
  • Input power:
    24 V DC
  • Station capacity:
    Up to 8 Field Control I/O modules
  • Input data capacity:
    Up to 128 bytes
  • Output data capacity:
    Up to 128 bytes
  • Bus devices per network:
    Up to 32
  • Supported station device numbers:
    0 to 31
  • Terminal screw torque:
    9 in-lb
  • Ground conductor:
    No. 14 AWG or larger; 4 in maximum
  • Terminal conductors:
    One No. 14 AWG or two No. 16 AWG copper; 75 degC

Information

Overview Manuals Common Applications Product Precautions
GE IC670GBI002 is ge fanuc field control genius bus interface unit, 24 vdc. It couples a Field Control station to a Genius network and coordinates data, configuration and diagnostics for the installed I/O modules.
  • Connects the station to Genius
  • Supports up to eight Field Control I/O modules
  • Exchanges configured input and output data with the host
  • Provides station and module diagnostic access

IC670GBI002 operates with Genius network, Field Control terminal block, Up to eight compatible I/O modules, 24 V DC station power.

Engineered applications include Genius bus interface field station, Remote I/O cabinet integration, Installed-base module renewal, Controlled commissioning and diagnostics.

Important Notice: Confirm IC670GBI002, 24 V DC station power, network address, bus termination and the configured I/O map before connecting the station to the host.

Apter Power IC670GBI002 Manuals and Guides

Apter Power IC670GBI002 Technical Data and System Reference PDFIC670GBI002 Field Installation and Commissioning Workbook PDF

The first document presents model-specific technical data and system identity. The second provides a separate installation, wiring and commissioning workflow.

Genius bus interface field station

Performs the documented genius bus interface function at a distributed Field Control station.

Remote I/O cabinet integration

Exchanges configured process data with the host through the installed bus interface.

Installed-base module renewal

Restores an exact catalog-number position while preserving terminal and data identity.

Controlled commissioning and diagnostics

Supports staged wiring, configuration, diagnostic and functional verification.

Read the applicable GE Fanuc Field Control instructions before work. Verify IC670GBI002, its terminal assignment and the installed station configuration.
1

Verify the complete IC670GBI002 catalog marking and assigned Field Control position before work.

2

Place the connected Genius process in its approved maintenance state before disturbing the station.

3

Isolate BIU and field power, then confirm a safe condition at the IC670GBI002 terminal block.

4

Label and record network conductors, shield, termination and field-power wiring before disconnecting any conductor from IC670GBI002.

5

Use ESD controls and protect the module connector, terminal block keying and exposed electronics.

6

Restore only the documented station address, data map and module configuration; do not copy settings from an adjacent module.

7

Energize in a controlled sequence and review PWR, channel, module and network diagnostics.

8

Complete network communication, module recognition and I/O response tests and retain the final result before returning the process to service.

Technical notes

Confirm IC670GBI002, 24 V DC station power, network address, bus termination and the configured I/O map before connecting the station to the host.

FAQ View All FAQ

  • What Field Control function is assigned to IC670GBI002?
    IC670GBI002 is ge fanuc field control genius bus interface unit, 24 vdc. It couples a Field Control station to a Genius network and coordinates data, configuration and diagnostics for the installed I/O modules.
  • Which station hardware must be paired with IC670GBI002?
    Use IC670GBI002 with the documented Field Control terminal block, compatible BIU or MFP, and the installed genius network.
  • Which IC670GBI002 identity should be checked before installation?
    Confirm the full IC670GBI002 catalog marking and the catalog number value IC670GBI002 against the installed station record.
  • How should field wiring be transferred when replacing IC670GBI002?
    Label and record network conductors, shield, termination and field-power wiring before disconnecting any conductor from IC670GBI002.
  • Which configuration item is critical when commissioning IC670GBI002?
    Restore only the documented station address, data map and module configuration; do not copy settings from an adjacent module.
  • What diagnostic checks apply to IC670GBI002?
    Energize in a controlled sequence and review PWR, channel, module and network diagnostics.
  • How should the IC670GBI002 signal path be functionally tested?
    Complete network communication, module recognition and I/O response tests and retain the final result before returning the process to service.
  • Can IC670GBI002 be replaced by a visually similar Field Control module?
    No direct substitution should be assumed. Match IC670GBI002, its terminal assignment, data allocation, signal type, power arrangement, and the documented terminal conductors value One No. 14 AWG or two No. 16 AWG copper; 75 degC before migration.
Manufacturers

Product Browsing History

Revisit the products you recently viewed on Apter Power.
SPEAK TO OUR TEAM
Let’s find the right solution for you.
Send us the part number, quantity and delivery destination. Our team will help confirm availability and lead time.
  • Whatsapp: +86 18030235313

    Send us a message.
  • sales13@apterpower.com

    Complete our online form.
  • +86 18030235313

    Speak to our team in your native language.