IC670GBI002

GE Fanuc Field Control Genius Bus Interface Unit, 24 VDC
In Stock
Ships by Tuesday, September 22
Fast Shipping Available

Product Describe:

GE IC670GBI002 is ge fanuc field control genius bus interface unit, 24 vdc. It couples a Field Control station to a Genius network and coordinates data, configuration and diagnostics for the installed I/O modules.

Ask our team:

Get a quick price for: IC670GBI002
Quantity*
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy.

Technical specifications for IC670GBI002

Technical specifications for IC670GBI002

  • Manufacturer:
    General Electric
  • Product Category:
    PLC Systems
  • Spare Part Number:
    IC670GBI002
  • Estimated shipping dimensions:
    16.2x10.9x10cm
  • Weight:
    0.68 kg
  • Tariff Code:
    8537101190
  • Counliy of origin:
    USA
  • Network:
    Genius bus
  • Input power:
    24 V DC
  • Station capacity:
    Up to 8 Field Control I/O modules
  • Input data capacity:
    Up to 128 bytes
  • Output data capacity:
    Up to 128 bytes
  • Bus devices per network:
    Up to 32
  • Supported station device numbers:
    0 to 31
  • Terminal screw torque:
    9 in-lb
  • Ground conductor:
    No. 14 AWG or larger; 4 in maximum
  • Terminal conductors:
    One No. 14 AWG or two No. 16 AWG copper; 75 degC

Information

Information

Overview Manuals Common Applications Product Precautions
GE IC670GBI002 is ge fanuc field control genius bus interface unit, 24 vdc. It couples a Field Control station to a Genius network and coordinates data, configuration and diagnostics for the installed I/O modules.
  • Connects the station to Genius
  • Supports up to eight Field Control I/O modules
  • Exchanges configured input and output data with the host
  • Provides station and module diagnostic access

IC670GBI002 operates with Genius network, Field Control terminal block, Up to eight compatible I/O modules, 24 V DC station power.

Engineered applications include Genius bus interface field station, Remote I/O cabinet integration, Installed-base module renewal, Controlled commissioning and diagnostics.

Important Notice: Confirm IC670GBI002, 24 V DC station power, network address, bus termination and the configured I/O map before connecting the station to the host.

Apter Power IC670GBI002 Manuals and Guides

Apter Power IC670GBI002 Technical Data and System Reference PDFIC670GBI002 Field Installation and Commissioning Workbook PDF

The first document presents model-specific technical data and system identity. The second provides a separate installation, wiring and commissioning workflow.

Genius bus interface field station

Performs the documented genius bus interface function at a distributed Field Control station.

Remote I/O cabinet integration

Exchanges configured process data with the host through the installed bus interface.

Installed-base module renewal

Restores an exact catalog-number position while preserving terminal and data identity.

Controlled commissioning and diagnostics

Supports staged wiring, configuration, diagnostic and functional verification.

Read the applicable GE Fanuc Field Control instructions before work. Verify IC670GBI002, its terminal assignment and the installed station configuration.
1

Verify the complete IC670GBI002 catalog marking and assigned Field Control position before work.

2

Place the connected Genius process in its approved maintenance state before disturbing the station.

3

Isolate BIU and field power, then confirm a safe condition at the IC670GBI002 terminal block.

4

Label and record network conductors, shield, termination and field-power wiring before disconnecting any conductor from IC670GBI002.

5

Use ESD controls and protect the module connector, terminal block keying and exposed electronics.

6

Restore only the documented station address, data map and module configuration; do not copy settings from an adjacent module.

7

Energize in a controlled sequence and review PWR, channel, module and network diagnostics.

8

Complete network communication, module recognition and I/O response tests and retain the final result before returning the process to service.

Technical notes

Technical notes

Confirm IC670GBI002, 24 V DC station power, network address, bus termination and the configured I/O map before connecting the station to the host.

FAQS

  • What Field Control function is assigned to IC670GBI002?
    IC670GBI002 is ge fanuc field control genius bus interface unit, 24 vdc. It couples a Field Control station to a Genius network and coordinates data, configuration and diagnostics for the installed I/O modules.
  • Which station hardware must be paired with IC670GBI002?
    Use IC670GBI002 with the documented Field Control terminal block, compatible BIU or MFP, and the installed genius network.
  • Which IC670GBI002 identity should be checked before installation?
    Confirm the full IC670GBI002 catalog marking and the catalog number value IC670GBI002 against the installed station record.
  • How should field wiring be transferred when replacing IC670GBI002?
    Label and record network conductors, shield, termination and field-power wiring before disconnecting any conductor from IC670GBI002.
  • Which configuration item is critical when commissioning IC670GBI002?
    Restore only the documented station address, data map and module configuration; do not copy settings from an adjacent module.
  • What diagnostic checks apply to IC670GBI002?
    Energize in a controlled sequence and review PWR, channel, module and network diagnostics.
  • How should the IC670GBI002 signal path be functionally tested?
    Complete network communication, module recognition and I/O response tests and retain the final result before returning the process to service.
  • Can IC670GBI002 be replaced by a visually similar Field Control module?
    No direct substitution should be assumed. Match IC670GBI002, its terminal assignment, data allocation, signal type, power arrangement, and the documented terminal conductors value One No. 14 AWG or two No. 16 AWG copper; 75 degC before migration.
Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, modules and cards, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer`s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

We’re Here When You Need Us

From product insights to customer service needs, our experienced service team will focus on getting you what you need quickly

Enquire

Complete our online form.

Call Us

Speak to one of our team.

Live Chat

Send us a message.