Technical specifications for IC200MDD843

  • Manufacturer:
    General Electric
  • Product Category:
    PLC Systems
  • Spare Part Number:
    IC200MDD843
  • Estimated shipping dimensions:
    11x5.8x6.6cm
  • Weight:
    0.15 kg
  • Tariff Code:
    8537101190
  • Counliy of origin:
    USA
  • System family:
    VersaMax I/O
  • Inputs:
    10 grouped 24 VDC positive logic
  • Outputs:
    6 relay outputs
  • Output rating:
    2 A per point
  • Output group limit:
    8 A maximum
  • Input filter:
    0, 1 or 7 ms selectable
  • Backplane allocation:
    10 input bits and 6 output bits
  • Status indication:
    Point LEDs and OK LED

Information

Overview Manuals Common Applications Product Precautions
IC200MDD843 shares one compact carrier position between discrete sensing and isolated switching, with separate input and relay power connections defined by the field wiring diagram.
  • Combines ten DC inputs and six relay outputs in one module.
  • Provides two-amp switching capability at each relay point.
  • Offers selectable input filtering for field-noise control.
  • Maps a fixed ten-input and six-output image to the VersaMax backplane.

IC200MDD843 should remain matched to its documented rack position, field interface and controller configuration through replacement and commissioning.

Important Notice: Record the complete IC200MDD843 identity, terminal assignments and channel response before removal, then prove the restored function before release.

GE IC200MDD843 Manuals & Downloads
GE IC200MDD843 Official Technical Reference Excerpt (PDF)GE IC200MDD843 Installation & Commissioning Guide (PDF)

The first document covers the product function, system role and technical selection. The installation guide covers identification, connection checks, commissioning and the acceptance record.

Machine interlocking
Reads sensors and switches relay-controlled devices from one slot.
Panel consolidation
Reduces carrier positions for mixed discrete points.
Utility sequencing
Combines permissive inputs with isolated relay commands.
VersaMax spare replacement
Restores the documented mixed-module point map.
Before installing GE IC200MDD843, confirm the documented system, interfaces and controlled configuration.
1
Confirm IC200MDD843 and the carrier keying before insertion.
2
Isolate both 24 VDC input power and relay load sources.
3
Record all ten input and six output terminal assignments.
4
Observe the eight-amp relay-group limit when reviewing connected loads.
5
Apply suppression appropriate to every inductive load.
6
Restore commons and external relay power without cross-connection.
7
Exercise each input with the selected software filter active.
8
Test every relay point under controlled load and review the PLC image before release.

Technical notes

Record the complete IC200MDD843 identity, terminal assignments and channel response before removal, then prove the restored function before release.

FAQ View All FAQ

  • How is GE IC200MDD843 divided between inputs and outputs?
    IC200MDD843 provides ten grouped 24 VDC positive-logic inputs and six relay outputs.
  • What current can each GE IC200MDD843 relay output switch?
    Each relay output is rated for up to 2 A within the documented voltage and load category limits.
  • Which group limit applies to GE IC200MDD843 outputs?
    The six-output group is limited to a combined maximum of 8 A.
  • How many PLC bits does GE IC200MDD843 use?
    It consumes ten input bits and six output bits in the VersaMax I/O map.
  • Which input-filter settings are available for GE IC200MDD843?
    The input filter can be configured for 0 ms, 1 ms or 7 ms.
  • What do the LEDs on GE IC200MDD843 indicate?
    Individual LEDs show point states and the OK LED indicates backplane power is present.
  • Why should inductive loads on GE IC200MDD843 use suppression?
    Suppression limits relay-contact arcing and voltage transients when coils are switched.
  • What should be proven after installing GE IC200MDD843?
    Exercise all ten inputs and six relays, confirm PLC mapping and verify load behavior under controlled conditions.
Manufacturers

Product Browsing History

Revisit the products you recently viewed on Apter Power.
SPEAK TO OUR TEAM
Let’s find the right solution for you.
Send us the part number, quantity and delivery destination. Our team will help confirm availability and lead time.
  • Whatsapp: +86 18030235313

    Send us a message.
  • sales13@apterpower.com

    Complete our online form.
  • +86 18030235313

    Speak to our team in your native language.