DS200TBQCG1ABB

Analog Input Milliamp I/O Termination Module
General Electric DS200TBQCG1ABB
General Electric DS200TBQCG1ABB
General Electric DS200TBQCG1ABB
General Electric DS200TBQCG1ABB
General Electric DS200TBQCG1ABB
General Electric DS200TBQCG1ABB
Product image is representative; revision or series may vary. Contact us to request a specific version.

Product Describe:

General Electric DS200TBQCG1ABB is a analog input milliamp i/o termination module for Mark V Speedtronic RST analog-I/O path.
  • Manufacturer part number
    DS200TBQCG1ABB
  • Shipping
    Swift global dispatch
  • Condition
    New, original product
  • Shipping size (est.)
    28.6cm x 7cm x 4cm
  • Country of Origin
    USA
Get a quick price for DS200TBQCG1ABB
E-mail *
Mobile
Company
Content *
Quantity *
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy

What happens after you enquire

  • 0

    Review your reference

    Send the complete DS200TBQCG1ABB reference, label photographs and required quantity.

  • 1

    Confirm the offer

    Confirm the offered revision, interfaces, included items and installed fit for DS200TBQCG1ABB.

  • 2

    Arrange dispatch

    Agree the DS200TBQCG1ABB quantity, dispatch date and delivery details in the quotation.

  • Match the complete marking

    Provide the complete DS200TBQCG1ABB label, installed-position photographs and connected-component identities.

  • Check the offered item before ordering

    Compare the offered DS200TBQCG1ABB hardware, interfaces and included items with the approved drawing.

Technical specifications for DS200TBQCG1ABB

  • Manufacturer:
    General Electric
  • Product Category:
    Gas Turbine Control
  • Spare Part Number:
    DS200TBQCG1ABB
  • Weight:
    0.32 kg
  • Tariff Code:
    8537101190
  • Product type:
    Analog Input Milliamp I/O Termination Module
  • Product family:
    DS200 / Mark V
  • Functional acronym:
    TBQC
  • Functional description:
    RST analog termination board
  • Input signal class:
    4-20 mA current inputs
  • Position signal class:
    LVDT/R position inputs
  • Output range selection:
    20 mA or 200 mA maximum by hardware jumper
  • Associated board path:
    TCQA analog I/O board
  • Installation context:
    RST-core terminal assembly
  • Revision suffix:
    G1ABB

Information

Overview Downloads Applications / Compatibility Product Precautions
  • DS200TBQCG1ABB is the complete offered reference for a analog input milliamp i/o termination module in Mark V Speedtronic RST analog-I/O path.
Installed-system continuity: Interfaces milliamp inputs, position inputs and configured milliamp outputs with the RST-core analog boards without redefining the approved equipment architecture.
Identity-led replacement: The complete DS200TBQCG1ABB marking keeps revision, interface and fitted-position decisions tied to the actual unit.
Controlled return to service: Connector, terminal, setting and diagnostic evidence are checked before the affected function is released.
DS200TBQCG1ABB performs a defined analog input milliamp i/o termination module role: it interfaces milliamp inputs, position inputs and configured milliamp outputs with the RST-core analog boards. Selection is based on the complete marking and the documented DS200 / Mark V execution.

The verified technical rows distinguish exact-model identity from family-level system context. Dimensions and weight are shipping estimates supplied for this offered item; technical acceptance follows the installed drawing and manufacturer evidence.

Before exchange, record the fitted position, every connector or terminal identity, adjustable settings and the healthy operating baseline. After installation, prove the affected function under a controlled site procedure.
Controller platform reference: Mark V Speedtronic RST analog-I/O path. Follow the applicable manufacturer instructions and approved equipment drawing.
Product references for General Electric DS200TBQCG1ABB: an applicable manufacturer reference or exact-model evidence brief, plus a separate installation and verification guide.
The manufacturer excerpt retains original technical pages. The separate Apter Power guide supports field verification for DS200TBQCG1ABB.
Prepare General Electric DS200TBQCG1ABB for its configured installation using these product-specific checks.
Capture the complete marking

Photograph DS200TBQCG1ABB and all secondary labels before removal.

Preserve installed settings

Record jumpers, switches, firmware, ranges or calibration references that apply.

Control stored energy

Follow the approved isolation and electrostatic handling procedure.

Label every connection

Mark conductors, plugs, fibers or tubing by their installed identifiers.

Inspect mating hardware

Check contacts, terminals, guides, supports and protective earth.

Prove the affected function

Verify diagnostics and actual process or equipment response before handover.

Alternative Names

General Electric DS200TBQCG1ABB Analog Input Milliamp I/O Termination Module DS200TBQCG1ABB

Technical notes

Evidence boundary: GE Mark V hardware reference GEH-6153

Exact-model rule: Do not infer interchangeability from a similar family code; match DS200TBQCG1ABB completely.

Acceptance record: Retain identity, interface, settings, diagnostics and functional proof.

FAQ View All FAQ

  • Which installed identity details must be recorded for DS200TBQCG1ABB?
    Record the full label, fitted position, connector or terminal map, and every adjustable setting before removal.
  • What interface check is most important before replacing DS200TBQCG1ABB?
    Compare the receiving hardware and every keyed, numbered or polarized connection with the approved drawing.
  • How should settings be controlled when servicing DS200TBQCG1ABB?
    Photograph and transcribe jumpers, switches, firmware or range selections that apply to this exact execution.
  • What should be inspected before fitting DS200TBQCG1ABB?
    Inspect contacts, terminal hardware, board supports, protective earth and nearby wiring for damage or contamination.
  • Which companion hardware must be verified with DS200TBQCG1ABB?
    Confirm the associated controller, terminal board, rack, power source or field device named by the installed design.
  • How should energization be managed after installing DS200TBQCG1ABB?
    Restore energy in the approved sequence, watch diagnostics, and stop if the expected healthy state is not obtained.
  • What functional proof adds technical value for DS200TBQCG1ABB?
    Exercise the affected signal, protection, power or communications path and retain before-and-after readings.
  • What handover record is required after commissioning DS200TBQCG1ABB?
    Keep the exact part marking, installed photographs, settings, test results, deviations and responsible approval.
SPEAK TO OUR TEAM
Let’s find the right solution for you.
Send us the part number, quantity and delivery destination. Our team will help confirm availability and lead time.
  • Whatsapp: +86 18030235313

    Send us a message.
  • sales13@apterpower.com

    Complete our online form.
  • +86 18030235313

    Speak to our team in your native language.