Speak to a sourcing specialist
sales13@apterpower.com

369-HI-R-0-0-0-0-E

Motor Management Relay
Product image is representative; revision or series may vary. Contact us to request a specific version.

Product Describe:

GE Multilin 369-HI-R-0-0-0-0-E is an enhanced 369 motor-management relay with HI control power and twelve built-in RTD inputs for motor protection and condition review.
  • Manufacturer part number
    369-HI-R-0-0-0-0-E
  • Shipping
    Swift global dispatch
  • Condition
    New, original product
  • Shipping size (est.)
    20.4cm × 14cm × 29.5cm
  • Country of Origin
    Canada
Get a quick price for 369-HI-R-0-0-0-0-E
E-mail *
Mobile
Company
Content *
Quantity *
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy

What happens after you enquire

  • 0

    Review your reference

    Send the complete 369-HI-R-0-0-0-0-E marking, installed revision, quantity and system configuration with your enquiry.

  • 1

    Confirm the offer

    Check that the quotation identifies 369-HI-R-0-0-0-0-E, its offered condition, included parts and dispatch date.

  • 2

    Arrange dispatch

    Confirm the delivery details and receive tracking information when shipment is arranged.

  • Match the complete marking

    Include 369-HI-R-0-0-0-0-E and every visible revision or serial identity in your enquiry. Keep the same complete reference on the quotation.

  • Check the offered item before ordering

    Request available label and connector photos. Have your maintenance team compare the offered 369-HI-R-0-0-0-0-E with the installed equipment and applicable GE documentation.

Technical specifications for 369-HI-R-0-0-0-0-E

  • Manufacturer:
    General Electric
  • Product Category:
    General Automation
  • Spare Part Number:
    369-HI-R-0-0-0-0-E
  • Weight:
    3.5 kg
  • Tariff Code:
    8537101190
  • Relay family:
    369 Motor Management Relay
  • Control supply:
    HI: 50–300 V DC or 60–265 V AC
  • Built-in RTD inputs:
    R: 12
  • Harsh-environment option:
    0: not selected
  • Faceplate/diagnostics:
    E: enhanced
  • Base analog output:
    One; additional outputs require M or B option
  • Mechanical execution:
    Non-drawout
  • Setup utility:
    EnerVista 369 Setup, with firmware-matched settings

Information

Overview Downloads Applications / Compatibility Product Precautions
  • GE Multilin 369-HI-R-0-0-0-0-E supervises a motor through the 369 protection platform, with the ordered RTD channels and enhanced diagnostic interface available for the installed motor scheme.
Configuration record: Save the motor settings and firmware before exchange
Thermal review: Map each installed RTD to the protected winding or bearing
Acceptance path: Test alarms and trips against the starter's operating state
The full order code identifies HI control power at 50–300 V DC or 60–265 V AC, twelve built-in RTD channels and the enhanced diagnostic faceplate. The RTD channels can be assigned to stator, bearing, ambient or driven-equipment sensing, with the sensor type selected in software.

The zero-option positions omit the optional metering or backspin package, fiber-optic port, extra protocol interface and harsh-environment execution. One analog output remains available on the base relay; the additional three analog outputs belong to the metering or backspin option and should not be attributed to this code.

Enhanced execution provides motor-status indicators, a Motor Health Report, learned motor data, a start data logger, an expanded event recorder and security-audit events. Protection performance still depends on the installed CT circuits, motor model, RTD wiring, programmed setpoints and relay firmware.
Controller platform reference: GE Multilin 369 motor protection. Retain CT and RTD schedules.
Technical downloads for General Electric 369-HI-R-0-0-0-0-E: a manufacturer technical excerpt and an Apter Power installation and commissioning guide.
The technical reference preserves selected manufacturer pages. The installation guide provides a model-specific field workflow; use the installed equipment instructions and site controls during work.
Commission 369-HI-R-0-0-0-0-E against the actual motor and starter, including HI supply, CT polarity, RTD wiring, thermal settings and trip contacts.
Protect CT circuits

Use the approved CT shorting/isolation procedure before disturbing current wiring, and verify ratio and polarity after work.

Match HI control power

Check the actual panel supply is inside 50–300 V DC or 60–265 V AC before energizing; do not use a LO relay's supply assumption.

Identify all RTD loops

Map each connected sensor to its motor location and chosen RTD type. Check lead continuity, sensor response and alarm assignment channel by channel.

Preserve motor settings

Export settings and record firmware, thermal model, CT ratios, RTD types, trip delays and output logic before replacement.

Respect omitted options

Do not plan optional metering/backspin, fiber, protocol or harsh-environment functions for the zero-coded positions.

Prove starter response

Test the intended trip/alarm outputs and breaker or contactor response in a controlled condition; restore the site-approved protection state.

Alternative Names

GE 369-HI-R-0-0-0-0-E GE Multilin 369-HI-R-0-0-0-0-E General Electric 369-HI-R-0-0-0-0-E

Technical notes

Motor protection relationship: Configure current-transformer ratios, motor thermal model, trip contacts and RTD inputs for the actual starter and motor. The R option supplies twelve built-in RTD channels; sensor type is selected in software.

Option boundary: The four zero positions omit the optional metering/backspin package, fiber port, protocol interface and harsh-environment package. The E suffix adds enhanced diagnostics and faceplate functions.

Technical reference: GE Multilin 369 Motor Management Relay Instruction Manual, 369man-bx. The full order code is explicitly listed as a HI/R/E example; actual firmware and protection setpoints are retained from the installed relay.

FAQ View All FAQ

  • What supply checks are needed before energizing 369-HI-R-0-0-0-0-E?
    Measure the auxiliary source at the relay terminals and compare it with the HI option's 50–300 V DC or 60–265 V AC range. Check protective wiring and the motor-starter interface before power-up; the HI code does not describe the site's actual connected voltage.
  • How should the RTD inputs of 369-HI-R-0-0-0-0-E be assigned to the motor?
    The R option provides twelve built-in RTD channels. Identify each connected sensor by winding or bearing location, verify its selected sensor type and loop continuity, and compare readings with the motor's known condition; unused channels should not be interpreted as measured temperatures.
  • Which optional functions must be excluded from a protection plan for 369-HI-R-0-0-0-0-E?
    The zero option in the metering/backspin position does not select those packages or their additional analog outputs. Preserve the base relay functions, including one analog output, but do not assign optional features or three extra outputs to this ordered unit without separate fitted-hardware evidence.
  • How should communications be planned for 369-HI-R-0-0-0-0-E without assuming a fiber port?
    The fiber-option position is zero. Identify the actual fitted communication hardware and terminal wiring, then confirm the protocol and configuration used by the site; the broader 369 family may support options that are not installed on this order code.
  • How can the enhanced diagnostics of 369-HI-R-0-0-0-0-E support fault review?
    The E execution adds an enhanced faceplate and diagnostic functions such as motor-health information, learned data, start logging and expanded event records, subject to installed firmware. Record the firmware revision and correlate events with motor operation before changing protection settings.
  • How should RTD faults be checked on 369-HI-R-0-0-0-0-E?
    Verify sensor type, loop wiring and channel assignment first. Compare temperature readings against the motor's known operating condition and investigate open, shorted or misassigned loops before changing trip thresholds.
  • Can 369-HI-R-0-0-0-0-E be swapped without restoring settings?
    No. Preserve the original firmware and settings, including CT ratios, thermal model, RTD types and trip-output mapping; compare the restored configuration with the motor protection study and test the starter interface.
  • What should be proven before 369-HI-R-0-0-0-0-E returns to service?
    Verify HI supply, CT inputs, each used RTD, alarm/trip logic, enhanced indications and the starter response under a controlled commissioning procedure.
Manufacturers

Product Browsing History

Revisit the products you recently viewed on Apter Power.
SPEAK TO OUR TEAM
Let’s find the right solution for you.
Send us the part number, quantity and delivery destination. Our team will help confirm availability and lead time.
  • Whatsapp: +86 18030235313

    Send us a message.
  • sales13@apterpower.com

    Complete our online form.
  • +86 18030235313

    Speak to our team in your native language.