PR9268/200-000

PR9268 Electrodynamic Velocity Sensor
In Stock
Ships by Sunday, September 20
Fast Shipping Available

Product Describe:

EPRO PR9268/200-000 is a pr9268 electrodynamic velocity sensor. It performs its documented measurement, power, connection or protective function within the installed Emerson EPRO machinery protection system.

Ask our team:

Get a quick price for: PR9268/200-000
Quantity*
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy.

Technical specifications for PR9268/200-000

Technical specifications for PR9268/200-000

  • Manufacturer:
    Epro
  • Product Category:
    Machinery Monitoring System
  • Spare Part Number:
    PR9268/200-000
  • Estimated shipping dimensions:
    25x22x8cm
  • Weight:
    1.05 kg
  • Tariff Code:
    8537101190
  • Counliy of origin:
    Germany
  • Measuring principle:
    Electrodynamic
  • Measuring direction:
    Vertical
  • Frequency range:
    4 to 1000 Hz
  • Natural frequency:
    4.5 Hz +/-0.75 Hz
  • Sensitivity:
    28.5 mV/(mm/s) +/-5%
  • Transverse sensitivity:
    0.13 at 110 Hz
  • Measuring-circuit resistance:
    1875 Ohm +/-10%
  • Insulation resistance:
    >1 MOhm at 500 V AC
  • Maximum measuring-direction deviation:
    +/-30 deg without sinking current
  • Maximum measuring-direction deviation with sinking current:
    +/-60 deg

Information

Information

Overview Manuals Common Applications Product Precautions
PR9268 Electrodynamic Velocity Sensor provides the documented interface for its installed Emerson EPRO machinery protection system system.
  • Provides the documented PR9268 Electrodynamic Velocity Sensor function
  • Maintains the engineered signal or power path
  • Integrates with the specified host and companion hardware
  • Supports controlled diagnostics and functional verification

The sensor converts absolute housing vibration velocity into an electrodynamic voltage signal for compatible machinery protection and condition-monitoring inputs. The installation uses the manufacturer-specified host position, companion hardware and field/control wiring for the intended industrial application.

System commissioning includes identity checks, connection verification, controlled energization and functional diagnostics for PR9268/200-000.

Important Notice: Confirm the complete PR9268/200-000 marking, approved system arrangement, connection records and controlled functional test before commissioning or replacement.

Apter Power PR9268/200-000 Manuals and Guides
Apter Power PR9268/200-000 Product Technical Reference PDFPR9268/200-000 Engineering Installation and Verification Workbook
The first document organizes model-specific technical identity and engineering data. The second provides a separate field workflow for installation, connection checks and commissioning records.
Emerson EPRO machinery protection system installed-base serviceDocumented host position and companion hardware supports the engineered PR9268/200-000 arrangement.
Emerson EPRO machinery protection system compatibility reviewApproved field or control wiring arrangement supports the engineered PR9268/200-000 arrangement.
Emerson EPRO machinery protection system installation planningRecorded connector, shield and grounding system supports the engineered PR9268/200-000 arrangement.
Emerson EPRO machinery protection system controlled commissioningConfigured monitor, controller or protection channel supports the engineered PR9268/200-000 arrangement.
Read the applicable EPRO installation instructions before work. Verify PR9268/200-000 and the installed-system configuration.
1Verify the complete PR9268/200-000 marking and installed position before work.
2Place the connected equipment in the approved maintenance state.
3Isolate applicable power and signal energy before disconnecting wiring.
4Use ESD controls and protect connectors from contamination or damage.
5Record as-found cable, terminal, shield and grounding identity.
6Restore only the approved system configuration for this exact catalog number.
7Inspect mechanical mounting and cable support before energization.
8Complete controlled diagnostics and a functional response test before release.

Technical notes

Technical notes

Install PR9268/200-000 only in the documented Emerson EPRO machinery protection system position and preserve the recorded connections. After installation, restore the approved configuration and complete controlled diagnostic and functional checks.

FAQS

  • What system role does PR9268/200-000 perform?
    It provides the documented pr9268 electrodynamic velocity sensor function within the Emerson EPRO machinery protection system.
  • Which identity checks are required before installing PR9268/200-000?
    Match the complete catalog marking, installed hardware position and companion components to the approved equipment record.
  • How should wiring or cabling for PR9268/200-000 be handled?
    Preserve connector identity, routing, shielding and grounding exactly as recorded for the installed system.
  • What must be isolated before replacing PR9268/200-000?
    Place the connected machine or controller in its approved maintenance state and isolate the applicable power and signal energy.
  • How is PR9268/200-000 configured after installation?
    Restore the documented channel, range, address or system-length configuration that applies to this exact assembly.
  • Which commissioning checks apply to PR9268/200-000?
    Use controlled energization followed by identity, connection, diagnostic and functional-response checks.
  • Can a similar catalog number replace PR9268/200-000 directly?
    Only after the complete ordering code, mechanical interface, electrical function and installed-system compatibility have been matched.
  • What maintenance record should be retained for PR9268/200-000?
    Record the as-found identity and connections together with the as-left configuration and functional-test result.
Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, modules and cards, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer`s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Product Browsing History

We’re Here When You Need Us

From product insights to customer service needs, our experienced service team will focus on getting you what you need quickly

Enquire

Complete our online form.

Call Us

Speak to one of our team.

Live Chat

Send us a message.