Speak to a sourcing specialist
sales13@apterpower.com

PR9268/200-000

PR9268 Electrodynamic Velocity Sensor
In Stock
Ships by Thursday, November 12
Fast Shipping Available
Product image is representative; revision or series may vary. Contact us to request a specific version.

Product Describe:

EPRO PR9268/200-000 is a pr9268 electrodynamic velocity sensor. It performs its documented measurement, power, connection or protective function within the installed Emerson EPRO machinery protection system.
Get a quick price for PR9268/200-000
E-mail *
Mobile *
Company
Content *
Quantity *
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy

What happens after you enquire

  • 1

    Requirement review

    We review the part number, quantity and delivery requirements and ask for any missing details.
  • 2

    Quotation and availability

    We confirm the proposed item, condition, availability, price and estimated lead time in the quotation.
  • 3

    Order confirmation and dispatch

    Once the quotation and purchasing details are agreed, your contact will coordinate the order and available dispatch information.

Technical specifications for PR9268/200-000

  • Manufacturer:
    Epro
  • Product Category:
    Machinery Monitoring Systems
  • Spare Part Number:
    PR9268/200-000
  • Estimated shipping dimensions:
    25x22x8cm
  • Weight:
    1.05 kg
  • Tariff Code:
    8537101190
  • Counliy of origin:
    Germany
  • Measuring principle:
    Electrodynamic
  • Measuring direction:
    Vertical
  • Frequency range:
    4 to 1000 Hz
  • Natural frequency:
    4.5 Hz +/-0.75 Hz
  • Sensitivity:
    28.5 mV/(mm/s) +/-5%
  • Transverse sensitivity:
    0.13 at 110 Hz
  • Measuring-circuit resistance:
    1875 Ohm +/-10%
  • Insulation resistance:
    >1 MOhm at 500 V AC
  • Maximum measuring-direction deviation:
    +/-30 deg without sinking current
  • Maximum measuring-direction deviation with sinking current:
    +/-60 deg

Information

Overview Manuals Common Applications Product Precautions
PR9268 Electrodynamic Velocity Sensor provides the documented interface for its installed Emerson EPRO machinery protection system system.
  • Provides the documented PR9268 Electrodynamic Velocity Sensor function
  • Maintains the engineered signal or power path
  • Integrates with the specified host and companion hardware
  • Supports controlled diagnostics and functional verification

The sensor converts absolute housing vibration velocity into an electrodynamic voltage signal for compatible machinery protection and condition-monitoring inputs. The installation uses the manufacturer-specified host position, companion hardware and field/control wiring for the intended industrial application.

System commissioning includes identity checks, connection verification, controlled energization and functional diagnostics for PR9268/200-000.

Important Notice: Confirm the complete PR9268/200-000 marking, approved system arrangement, connection records and controlled functional test before commissioning or replacement.

Apter Power PR9268/200-000 Manuals and Guides
Apter Power PR9268/200-000 Product Technical Reference PDFPR9268/200-000 Engineering Installation and Verification Workbook
The first document organizes model-specific technical identity and engineering data. The second provides a separate field workflow for installation, connection checks and commissioning records.
Emerson EPRO machinery protection system installed-base serviceDocumented host position and companion hardware supports the engineered PR9268/200-000 arrangement.
Emerson EPRO machinery protection system compatibility reviewApproved field or control wiring arrangement supports the engineered PR9268/200-000 arrangement.
Emerson EPRO machinery protection system installation planningRecorded connector, shield and grounding system supports the engineered PR9268/200-000 arrangement.
Emerson EPRO machinery protection system controlled commissioningConfigured monitor, controller or protection channel supports the engineered PR9268/200-000 arrangement.
Read the applicable EPRO installation instructions before work. Verify PR9268/200-000 and the installed-system configuration.
1Verify the complete PR9268/200-000 marking and installed position before work.
2Place the connected equipment in the approved maintenance state.
3Isolate applicable power and signal energy before disconnecting wiring.
4Use ESD controls and protect connectors from contamination or damage.
5Record as-found cable, terminal, shield and grounding identity.
6Restore only the approved system configuration for this exact catalog number.
7Inspect mechanical mounting and cable support before energization.
8Complete controlled diagnostics and a functional response test before release.

Technical notes

Install PR9268/200-000 only in the documented Emerson EPRO machinery protection system position and preserve the recorded connections. After installation, restore the approved configuration and complete controlled diagnostic and functional checks.

FAQ View All FAQ

  • What system role does PR9268/200-000 perform?
    It provides the documented pr9268 electrodynamic velocity sensor function within the Emerson EPRO machinery protection system.
  • Which identity checks are required before installing PR9268/200-000?
    Match the complete catalog marking, installed hardware position and companion components to the approved equipment record.
  • How should wiring or cabling for PR9268/200-000 be handled?
    Preserve connector identity, routing, shielding and grounding exactly as recorded for the installed system.
  • What must be isolated before replacing PR9268/200-000?
    Place the connected machine or controller in its approved maintenance state and isolate the applicable power and signal energy.
  • How is PR9268/200-000 configured after installation?
    Restore the documented channel, range, address or system-length configuration that applies to this exact assembly.
  • Which commissioning checks apply to PR9268/200-000?
    Use controlled energization followed by identity, connection, diagnostic and functional-response checks.
  • Can a similar catalog number replace PR9268/200-000 directly?
    Only after the complete ordering code, mechanical interface, electrical function and installed-system compatibility have been matched.
  • What maintenance record should be retained for PR9268/200-000?
    Record the as-found identity and connections together with the as-left configuration and functional-test result.